X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-22688

Well Details

Well ID: 34-059-22688
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Valley Township
Operator Name: DOVER ATWOOD CORP.
Well Pad ID:
Farm/Lease Name: KOPOLA LEWIS & SOPHIE
License Status: Active Injection
License Date: 1984-02-22
Spud Date: 1980-06-14
Spud Drilling Contractor: BURDETTE DRLG
Final Drill Date: 1980-06-28
Well Total Depth: 5395.00 ft
Configuration: Vertical
Latitude: 39.910000
Longitude: -81.500000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-12-31 122 TIGER OIL INC GeoDate 12/31/79
Original Spud 1980-06-14 CONVERTED FROM OIL AND GAS TO SWIW CONVERT 2-25-84 SWIW
Reached Total Depth 1980-06-28 CONVERTED FROM OIL AND GAS TO SWIW CONVERT 2-25-84 SWIW
CO 1984-02-22 122 TIGER OIL INC GeoDate 2/22/84
Conversion to Injector 1984-02-22
Salt Water Injection Well 1984-02-22 Issued Date 2/22/84 Expired Date 8/20/84 Acres 0060000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Storage Well 1984-02-22 Issued Date 2/22/84 Expired Date 8/20/84 Acres 0060000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Construction Permit Expires 1984-08-20 CONVERTED FROM OIL AND GAS TO SWIW CONVERT 2-25-84 SWIW
Completed 1984-08-28 CONVERTED FROM OIL AND GAS TO SWIW CONVERT 2-25-84 SWIW
First Injection 1985-05-03 CONVERTED FROM OIL AND GAS TO SWIW CONVERT 2-25-84 SWIW
Annulus Pressure Monitoring Approved 1993-12-09 CONVERTED FROM OIL AND GAS TO SWIW CONVERT 2-25-84 SWIW
CO 1994-12-27 2680 ENERGY CONTRACTORS INC GeoDate 2/22/84
Change of Owner 2000-10-16 Operator changed from 2680, ENERGY CONTRACTORS INC to 4540, PEOPLES PETROLEUM CORP.
Change of Owner 2005-07-08 Operator changed from 4540, PEOPLES PETROLEUM CORP. to 5935, DOVER ATWOOD CORP.
Last Compliance Report 2016-02-05 CONVERTED FROM OIL AND GAS TO SWIW CONVERT 2-25-84 SWIW
Record Last Modified 2017-10-19 CONVERTED FROM OIL AND GAS TO SWIW CONVERT 2-25-84 SWIW

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-04-28 5234 5250 1
5234 5250 1
5234 5250 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 500 Gal 0
H2O 0 1000 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TIGER OIL INC 6725.00 0.00 0
1985 TIGER OIL INC 5767.00 0.00 365
1986 TIGER OIL INC 4951.00 0.00 365
1987 TIGER OIL INC 2006.00 0.00 365
1989 TIGER OIL INC 985.00 0.00 365
1990 TIGER OIL INC 1482.00 0.00 365
1991 TIGER OIL INC 1015.00 22.00 365
1992 TIGER OIL INC 2124.00 0.00 365
1993 TIGER OIL INC 160.00 10.00 30
1994 TIGER OIL INC 1467.00 10.00 365
2012 DOVER ATWOOD CORP. 2374.00 0.00 366
2013 DOVER ATWOOD CORP. 760.00 0.00 365
2016 DOVER ATWOOD CORP. 0.00 0.00 0
2017 DOVER ATWOOD CORP. 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TIGER OIL INC Brine 0 0
1985 TIGER OIL INC Brine 0 365
1986 TIGER OIL INC Brine 0 365
1987 TIGER OIL INC Brine 0 365
1989 TIGER OIL INC Brine 0 365
1990 TIGER OIL INC Brine 0 365
1991 TIGER OIL INC Brine 0 365
1992 TIGER OIL INC Brine 0 365
1993 TIGER OIL INC Brine 0 30
1994 TIGER OIL INC Brine 0 365
2012 DOVER ATWOOD CORP. Brine 0 366
2013 DOVER ATWOOD CORP. Brine 0 365
2016 DOVER ATWOOD CORP. Brine 0 0
2017 DOVER ATWOOD CORP. Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1020885307 2015-6-24 0:00: SW No Violations
-1025945632 2016-8-1 0:00:0 SW No Violations
-104632840 2013-8-19 0:00: SW No Violations 1.00
-1063392350 2010-8-5 0:00:0 SW No Violations
-1083206181 2017-2-7 0:00:0 SW No Violations
-1087598682 2018-2-26 0:00: SW No Violations
-1126903201 2008-7-8 0:00:0 SW No Violations
-1175998563 2020-7-9 0:00:0 SW No Violations
-1185859063 2011-9-7 0:00:0 SW No Violations
-1193653954 2016-12-21 0:00 SW No Violations
-1232666694 2013-7-29 0:00: SW No Violations 8.00
-1260330521 2016-9-21 0:00: SW No Violations
-1281369031 2006-1-31 0:00: SW No Violations
-1420398019 2013-7-26 0:00: SW No Violations
-1427771774 2015-8-10 0:00: SW No Violations
-1511054506 2016-5-17 0:00: SW No Violations
-1533072140 2013-10-21 0:00 SW No Violations
-1564789131 2017-9-6 0:00:0 SW No Violations
-1575537221 2007-4-24 0:00: SW No Violations
-1625065992 2012-8-3 0:00:0 SW No Violations
-1648961236 2013-5-9 0:00:0 SW No Violations 1.00
-1650391719 2010-11-26 0:00 SW No Violations
-1664108821 2009-2-24 0:00: SW No Violations
-1668126558 2017-4-21 0:00: SW No Violations
-1688755877 2017-9-19 0:00: SW No Violations
-1715020915 2008-9-3 0:00:0 SW No Violations
-177651876 2007-1-11 0:00: SW No Violations
-1847895669 2017-6-13 0:00: SW No Violations
-1941875039 2010-2-1 0:00:0 SW No Violations
-2079205866 2011-8-9 0:00:0 SW No Violations
-2085663621 2019-4-17 0:00: SW No Violations
-2088890030 2014-3-12 0:00: SW No Violations
-2121333805 2010-4-7 0:00:0 SW No Violations
-219042070 2005-10-4 0:00: SW No Violations
-264368428 2005-2-2 0:00:0 SW No Violations
-3176798 2014-1-8 0:00:0 SW No Violations
-331905581 2019-7-29 0:00: SW No Violations
-354515295 2009-10-6 0:00: SW No Violations
-380733372 2013-4-23 0:00: SW No Violations 1.00
-388839791 2019-10-17 0:00 SW No Violations
-407007488 2008-2-13 0:00: SW No Violations
-434661715 2007-1-10 0:00: SW No Violations
-4928428 2007-1-16 0:00: SW No Violations
-501411122 2010-5-3 0:00:0 SW No Violations 1.00
-530996719 2011-3-7 0:00:0 SW No Violations
-565629934 2020-6-2 0:00:0 SW No Violations
-57615449 2016-1-11 0:00: SW No Violations
-579218145 2013-9-13 0:00: SW No Violations
-680436810 2014-8-4 0:00:0 SW No Violations
-696881695 2018-4-6 0:00:0 SW No Violations
-763112155 2011-7-5 0:00:0 SW No Violations
-869326484 2013-12-10 0:00 SW No Violations
-984144885 2010-7-8 0:00:0 SW No Violations
0003176798 2014-01-08 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one company owned vacuum truck was unloading at site during my inspection.
0004928428 2007-01-16 Salt Water Injection Well No Violations WORKING ON DIKE. DRAINING RAIWTER OUT OF DIKE AREA. COMPACTING DIKE WALLS.
000UIC1158 1991-09-18 Salt Water Injection Well No Violations 1501: 9-3-07 (E)&(F) QUARTERLY REPORTS
000UIC1370 1993-01-12 Salt Water Injection Well No Violations ACTION CH.ORD 1501: 9-3-07 (J) OPERATIONS
000UIC1472 1993-10-18 Salt Water Injection Well No Violations 1501: 9-3-07 (J) OPERATIONS
001289i496 2002-07-05 Salt Water Injection Well No Violations injection pressure is on vacuum
0057615449 2016-01-11 Salt Water Injection Well No Violations Inspection on this day indicated that injection pump was in operation and it was noted that owner will need to have fresh water removed from dike area to allow for volume in the event of spill.
0063178784 2011-05-19 Salt Water Injection Well No Violations On site with Tom Tomastik to inspect well site.

Note: Unloading pad needs to be cleaned and sand or gravel needs to be placed on exposed liner to prevent it from splitting from being exposed to severe sunlight.

0087340744 2012-08-21 Salt Water Injection Well No Violations On site with UIC Director and group from Central Office to inspect well site and surface facility.

Note: Exposed portion of pit liner needs to be covered with stone to help prevent exposure to sunlight liner is showing signs of fatigue and once liner displays loss integrity we may require it to be removed and replaced and fresh water needs to be removed from dike area to help prevent plumbing from rotting due to being exposed to standing water levels.

0092311010 2018-05-02 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection and it was noted that one JHAWK Water Service vacuum truck was offloading at site during my inspection.
0102240320 2014-04-23 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jayhawk Water Service vacuum truck was unloading at facility during my inspection.
0104632840 2013-08-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
0147570442 2016-11-21 Salt Water Injection Well No Violations On site to witness MIT testing of said well they pressured up too 800 psi and we monitored pressure for 15 minutes with a 20 psi loss in pressure which equals 2.5% loss and MIT test passed.
0169970342 2009-04-29 Salt Water Injection Well No Violations Inspection revealed that well is operation,well is equipped with 8 surface casing and 4.5 production casing and 2.875 tubing and 1.5 tubing,well is currently gravity fed there is 3-210 bbl tanks and 1-100 bbl tank within dike area and unloading pad is in need of being cleaned in the near future.
0177651876 2007-01-11 Salt Water Injection Well No Violations SAND SPREAD ( 5) AND LINER LAID DOWN, SPREADING SAND OVER LINER. CUT BENCH ON TOP OF DIKE AREA TO HOLD LINER FROM SLIPPING.
0219042070 2005-10-04 Salt Water Injection Well No Violations INSPECTED WELL AND LOAD OUT FACILITY. NO VIOLATIONS NOTED THIS INSPECTION. WELL IS NOT BEING USED AT THIS TIME.
0221164867 2010-07-08 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 1278717710 On site to witness operator apply annulus pressure to tubing and monitor pressure for 15 min. with no decline in pressure(TEST PASSED).Well is currently gravity fed only at this time.
0264368428 2005-02-02 Salt Water Injection Well No Violations SALT WATER INJECTION WELL. APPARENTLY HAS NOT BEEN BEING USED. NO EVIDENCE OF RECENT ACTIVITY AROUND FACILITY. COULD NOT GET GAUGE ON ANY OF FITTINGS TO TAKE ANY TESTS. VALVES IN DETERIORATED CONDITION.
0268798716 2008-10-06 Salt Water Injection Well No Violations PRESSURE TEST RAN 31-JULY- 08 650 ON ANNULUS, VAC ON TUBING. UNLOADING PAD AND FACILITY LOOKS GOOD.
0322076186 2003-04-30 Salt Water Injection Well No Violations SWIW WELL #3. ID COULD USE BRIGHTENING UP WILL NOTIFY OPERATOR
0342354710 2012-05-25 Salt Water Injection Well No Violations Inspection revealed that company owned vacuum truck was unloading at site during my inspection, it was discussed that restoration work at site needed to be addressed and driver stated he would talk to owner and get time frame set on when restoration work would be completed.
0354515295 2009-10-06 Salt Water Injection Well No Violations Inspection revealed that well is in operation it is gravity fed only at this time, called and talked to company rep requesting that that perform mini test on annulus of tubing he stated that as soon as there truck was repaired they would call and schedule test.
0354927079 2006-08-17 Salt Water Injection Well No Violations J-HAWK WATER SERVICE GRAVITY FED LOAD OF WATER DOWN HOLE WITH NO APPARENT LEAKS IN FLOW LINE.
0359336771 2015-12-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection on this day.
0380733372 2013-04-23 Salt Water Injection Well No Violations On the day of my inspection I accompanied Dave Ball. Pressures on well were 70 lb on the tubing and 840 lb on the annulas. The pump was running. No violations noted.
0403336074 2013-03-22 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that annulus pressure was at zero and I called company rep and requested pressure testing of annulus.
0407007488 2008-02-13 Salt Water Injection Well No Violations INSPECTED SWIW#3.
0434661715 2007-01-10 Salt Water Injection Well No Violations RECONSTRUCTION OF SWIW TANK PAD.REMOVED TANKS. DUG OUT NEW DIKE AREA 75X25X5. WORKING ON DIKE AREA. COMPACTING SOIL ON DIKE.TOP OF DIKE WILL BE APPROXIMATELY 6-7FT. FROM BOTTOM OF DIKE AREA.STARTING TO INSTALL SAND ON BOTTOM. WILL BE INSTALLING LINER ON 1-11-07.
0501411122 2010-05-03 Salt Water Injection Well No Violations Inspection revealed that well is in operation(gravity fed only at this time) will need to apply pressure to annulus of tubing as soon as weather permits.
0512738448 2018-07-17 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
0530996719 2011-03-07 Salt Water Injection Well No Violations Inspection revealed that well is in operation and is gravity fed only at this time.

Note: Old filter housings at unloading pad need to be removed from site and housekeeping is needed in unloading area.

0554395372 2011-05-11 Salt Water Injection Well No Violations On site to witness owner replace flowline and pressure test new line.

Tested line@200 psi with no decline in pressure after 15 minutes(TEST PASSED).

0569528767 2008-11-14 Salt Water Injection Well No Violations WELL IS IN OPERATION. NO VIOLATIONS NOTED THIS INSPECTION
0579218145 2013-09-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and I called well caretaker and requested that they apply more positive pressure to annulus of tubing in the near future.
0593710393 2011-09-08 Salt Water Injection Well No Violations Attempted to release packer but tubing parted@5050 rig crew will attempt to fish remaining tubing and packer tomorrow and then they will possibly run new packer and tubing back in well early next week.
0598392296 2014-06-17 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and I call company rep requesting that they perform weed eating around storage tank area and wellhead area.
0620180294 2010-12-30 Salt Water Injection Well No Violations On site to witness well owner replace plumbing on wellhead and replace filter housings at unloading pad,once job was completed they filled lines and filters and we pressure tested replaced equiptment.

Note: No leakage was noted during pressure test.

0654157695 2018-09-28 Salt Water Injection Well No Violations On site along with Bill Grimm with JHAWK Water Services to witness mini testing of annulus of tubing he applied 560 psi and we monitored pressure for 15 minutes with no decline in pressure.
0680436810 2014-08-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one Jayhawk Water Service vacuum truck was unloading at facility during my inspection.
0681129476 2003-06-30 Salt Water Injection Well No Violations WELL IS SITTING BACK IN WETLAND(SWAMP). LANDOWNER HAS GATE ACROSS ROAD AND ONLY ACESS IS BY WALKING. WELL APPARENTLY HAS NOT BEEN USED FOR SOME TIME. WEEDS HAVE BEEN CUT AROUND DIKE AREA.
0696881695 2018-04-06 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection.


Note: Contacted well owner and requested positive pressure be applied to annulus of tubing.

0710352820 2007-01-19 Salt Water Injection Well No Violations WILL ORDER LARGER PIT LINER. 140X75. DUE TO NORTH WALL OF DIKE. WET WEATHER SPRING IN AREA. THIS COULD CAUSE CONTINOUS CAVING OF DIKE WALL AND CREATE AN ON GOING PROBLEM. A LARGER LINER WOULD,I THINK ALLEVIATE THIS PROBLEM. LINR ORDERED WILL HAVE TO WAIT
0737939379 2013-07-30 Salt Water Injection Well No Violations On site to witness setting and pressure testing of tubing and annulus of tubing. Flushed annulus of tubing with 25 bbl of fresh water and then they added 5 gallon of inhibitor and pumped additional 15 bbl inhibitor laden fluid and they attempted to set packer and test ,after several attempts we were finally able to get packer set and pressure tested they applied 740 psi to annulus and we monitored pressure for 15 minutes with no decline in pressure, once test was completed rig crew ran tools in tubing to remove standing valve they had a hard time retrieving valve but it was removed from well.
0755561001 2018-09-14 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.

Note: Weed eating around dike area has been recently completed.

0763112155 2011-07-05 Salt Water Injection Well No Violations Inspection revealed that well is in operation gravity fed only at this time.

Note: Area below dike wall will need to have vegetation established in near future.

0869326484 2013-12-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one Jayhawk Water Service vacuum truck was unloading at facility during my inspection.

Note : Called company rep and requested that they have positive pressure applied to annulus of tubing to confirm that they have casing integrity.

0871435545 2016-01-25 Salt Water Injection Well No Violations Injection pump was in operation during my inspection.
0875182491 2017-06-28 Salt Water Injection Well No Violations Company owned pressure treating truck on site to apply pressure to annulus of tubing.
0896905511 2010-06-08 Salt Water Injection Well No Violations Inspection revealed that well is in operation gravity fed only at this time.

Note: Fresh water needs to be removed from dike area too allow for space in the event of tank failure, also weed eating needs to be preformed around wellhead and tank area.

0897337543 2014-07-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that one Jayhawk Water Service was unloading at facility during my inspection.
0915187015 2013-08-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jayhawk Water Service vacuum truck was unloading at facility during my inspection.
0916323996 2015-07-14 Salt Water Injection Well No Violations

Inspection revealed that injection pump was in operation during my inspection and it was noted that owner has recently placed fencing in area of well head to help keep cattle from entering this area. Note: Dike capacity was figured as 1332 bbl.

0935931782 2018-06-25 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection and it was noted that one JHAWK vacuum truck was on site during my inspection.
0954001049 2008-12-31 Salt Water Injection Well No Violations WELL IS BEING USED. STILL ON A VACCUM. SURFACE FACILITES IN GOOD REPAIR. NO VIOLATIONS NOTED THIS INSPECTION.
0984144885 2010-07-08 Salt Water Injection Well Violations Noted FOLLOW UP TO NOV # 221164867 FOLLOW UP TO NOV # 1278717710 On site to witness operator apply annulus pressure to tubing and monitor pressure for 15 min. with no decline in pressure(TEST PASSED).Well is currently gravity fed only at this time.
1020885307 2015-06-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that owner has recently weedeated at storage tank site and also in the area of the injection pump.
102240320 2014-4-23 0:00: SW No Violations
1025945632 2016-08-01 Salt Water Injection Well No Violations Injection pump not in operation during my inspection.
1063392350 2010-08-05 Salt Water Injection Well No Violations Inspection revealed that well is gravity fed only,noted fresh water build up in dike area called and talked to well tender and suggested that he remove fresh water from dike and he stated that he was on his way to well site and he would remove water from dike today.
1076758944 2007-01-17 Surface Facility Construction No Violations MIKE BOOKE CO. RE-INSTALLING LINER INSIDE DIKE AREA ON SWIW.
1083206181 2017-02-07 Salt Water Injection Well No Violations Injection pump was not in operation during my inspection.
1087598682 2018-02-26 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation today and it was noted that two inch valve on annulus of tubing has frozen and cracked called company and requested that valve be changed and positive pressure applied to annulus of tubing.
1093317057 2015-10-16 Salt Water Injection Well No Violations Inspection on this day indicated that injection pump was in operation during my inspection.

Note: One J-Hawk water truck was unloading at the facility on this day.

1103320882 2012-03-05 Salt Water Injection Well No Violations Inspection revealed that well is in operation and is gravity fed only at this time.

Note: Restoration work at site still needs to be performed as weather permits.

1113525393 2005-04-14 Salt Water Injection Well No Violations FIRST TEST OPERATOR DID NOT BRING ENOUGH NITROGEN TO GET UP TO TEST PRESSURE. SECOND TEST AT 720# HELD FOR 15 MINUTES.
1126903201 2008-07-08 Salt Water Injection Well No Violations DALE SALING UNLOADING WATER AT WELL.CHECKED LOG BOOK. EVERYTHING IN ORDER. UNLOADING PAD AND DIKE AREA IN GOOD REPAIR.
1147770879 2008-10-15 Salt Water Injection Well No Violations WELL IS IN OPERATION. FACILITY IS IN GOOD REPAIR
1153764640 2006-07-24 Salt Water Injection Well No Violations JIMMY HAWKINS(J HAWK) WATER SERVICE. MET ON LOCATION STARTED CLEANING UP AROUND TANK SITE. AND DISCUSSED FLOW LINE, WHETHER TO USE ORIGINAL LINE OR TO RUN PLASTIC THRU EXISTING LINE. ALSO DISCUSSED BERMING UNLOADING PAD.
1156858694 2006-08-29 Salt Water Injection Well No Violations MET JIM HAWKINS AT WELL SITE.(J-HAWK WATER SERVICE). DISCUSSED PLACEMENT OF LARGER VESSELS INSIDE TANK DIKE. AND RE-CONSTRUCTION OF TANK DIKE TO HOLD TANK CAPACITY WITHIN DIKE. WELL IS STILL ON VACUUM AT THIS TIME. ALSO INSPECTED NEW LINE LAID FROM TANK SITE TO WELL HEAD
1164623261 2008-12-02 Salt Water Injection Well No Violations SALT WATER INJECTION WELL INSPECTION. NO VIOLATIONS NOTED.
1176942744 2007-04-18 Salt Water Injection Well No Violations LINER SPREAD TODAY. 175X65 M&M TRUCKING BROUGHT IN AND BLEW ON 37 TON OF SAND ON LINER. WILL BRING IN 4 MORE LOADS TO BLOW ON STATRING TOMORROW. WILL SPREAD SAND ON LINER UNTIL THIS PHASE IS COMPLETE. WILL USE CRANE TO LIFT TANKS INTO DIKE.
1176992749 2007-04-19 Salt Water Injection Well No Violations RECONSTRUCT DIKE AREA. MORE SAND BLOWN IN ON LINER. WORKING ON EXTENDING PAD OUT 5. CHECKED WELL FOR INTEGRETY. VAC/0
1177607740 2007-04-26 Salt Water Injection Well No Violations WORK ON GOING AROUND TANK SITE AND UNLOADING PAD.
1178106939 2007-05-01 Salt Water Injection Well No Violations WELDING TANKS TODAY. NEW VENTS LADDER HOLDS. WORKING ON MAIN INJECTION LINE.
1178127400 2007-05-02 Salt Water Injection Well No Violations GETTING TANKS READY TO SET. GOING TO USE CRANE TO SET TANKS INSIDE DIKE.
1178279547 2007-05-03 Salt Water Injection Well No Violations NICOLOZAKES CRANE SETTING IN TANKS IN DIKE AREA.FIRST TWO TANKS HAD MAJOR PROBLEMS GETTING TANKS SET DUE TO LENGTH OF REACH OF CRANE. HAD TO SKID TANKS ON 3 PIPE OUT TO END OF DIKE AND SET THE OTHER THREE AND PROPERLY SPACE. ADJUST TANKS WHERE WALKWAYS ARE CORRECT.
1179848774 2007-05-21 Salt Water Injection Well No Violations STATUS CHECK
1181854265 2007-06-14 Salt Water Injection Well No Violations WATER BEING PUT AWAY IN WELL. FACILITY UP AND RUNNING. SMALL DETAILS NEED TO BE PUT TOGETHER ON TANK FACILITY BEFORE COMPLETE. DALE SALING IN FACILITY, UNLOADING WATER AT THIS TIME.
1185859063 2011-09-07 Salt Water Injection Well No Violations Inspection revealed that Knox Energy has moved service rig in on location to change out tubing on said well it appears that top joint is showing signs of fatigue area below collar is getting thin so decision was made to change out tubing.
1193653954 2016-12-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and one J-HAWK Oilfield Services vacuum truck was unloading at the facility today.
1208392810 2008-04-14 Salt Water Injection Well No Violations WELL IS IN OPERATION. FACILITY BEING KEPT CLEAN AND ORDERLY
1210283132 2008-05-07 Salt Water Injection Well No Violations INSPECTED SWIW#3.CHECKED DRIVERS LOG ON UNLOADING PAD AND FOUND EVERYTHING IN ORDER. UNLOADING PAD WAS VERY CLEAN AND DIKE AREA WAS FOUND TO BE IN GOOD REPAIR.
1210854196 2008-05-15 Salt Water Injection Well No Violations DUE TO HEAVY RAINFALL CHECKED FLOW LINE TO WELL ACROSS CREEK. UNLOADING PAD IS BEING KEPT CLEAN. TANK PAD IS IN GOOD REPAIR.
1213050502 2008-06-09 Salt Water Injection Well No Violations SALT WATER INJECTION WELL
1216987917 2008-07-25 Salt Water Injection Well No Violations SALT WATER INJECTION WELL. DIKE AREA AND UNLOADING PAD MIN GOOD REPAIR. NO VIOLATIONS NOTED.
1232666694 2013-07-29 Salt Water Injection Well No Violations On site to witness rebuilt packer and tubing run into well, rig crew ran 5178 of used 1.5 tubing in well and packer setting depth is@5145 unable to set today due too not having freshwater and inhibitor on site will attempt to set packer and pressure test tomorrow.
1250269687 2009-08-14 Salt Water Injection Well No Violations Inspection revealed that well is being used SWIW gravity fed to tubing, well is equipped with 3-210 bbl tanks and there is 8 surface pipe and 4.5 production casing and 2.875 tubing and 1.5 tubing.

Suggest weed eating path to wellhead and schedule mini test on annulus of tubing ASAP AND CALL INSPECTOR PRIOR TO PREFORMING TEST.

1253307335 2009-09-18 Salt Water Injection Well No Violations Inspection revealed that well is in operation owner is gravity feeding salt water into injection zone.

Suggest pressure test on annulus of tubing contact inspector prior to preforming required test and also place proper I.D. on wellhead and tanks.

1256716500 2009-10-27 Salt Water Injection Well No Violations On site to witness operator apply positive pressure to annulus of tubing J-Hawk Water Service applied 250 psi and I monitored pressure for 15 min with no decline in pressure MINI TEST PASSED.

Note: Stone needs applied to road going to wellhead up to the point where you cut off to enter field, and weeds need to be weedeated from around wellhead area.

1260330521 2016-09-21 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection.
1278717710 2010-07-08 Salt Water Injection Well Violations Noted On site to witness operator apply annulus pressure to tubing and monitor pressure for 15 min. with no decline in pressure(TEST PASSED).Well is currently gravity fed only at this time.
1281369031 2006-01-31 Salt Water Injection Well No Violations WELL NOT IN OPERATION
1281930485 2010-12-29 Salt Water Injection Well No Violations Inspected site along with supervisor and discovered that collar on tubing had failed and there was brine on the ground approximately 50 bbl contacted well owner and requested immediate clean up ,company responded with 2 vac trucks and back hoe and dump truck to remove contaminated soil and replaced with fresh soil and area was seeded and mulched, will check back on site tomorrow too see if any further cleanup is needed.
1289i21357 2002-03-27 Annular Disposal No Violations A.D. WELL INJECTION PRESSURE ON VACUUM.
1289i21357277 2002-3-27 0:00: AD No Violations
1289i21953 2001-05-16 Salt Water Injection Well No Violations
1289i21953804 2001-5-16 0:00: SW No Violations
1289i496 2002-7-5 0:00:0 SW No Violations
1302118416 2011-04-06 Salt Water Injection Well No Violations Inspection revealed that well is in operation and is gravity fed only at this time.

Note: Old filter housings need to be removed from site and unloading pad needs a good cleaning and also fresh water needs to be removed from dike area.

1305067228 2011-05-10 Salt Water Injection Well No Violations On site to witness Jim Hawkins and crew replace flowline to wellhead they inserted 1.250 tubing inside of 2 tubing too wellhead will pressure test tomorrow.
1315871873 2011-09-12 Salt Water Injection Well No Violations Service rig ran overshot in hole to try to retrieve remaining tubing and packer. They pulled 25,000 pounds on string and shut down for the day. They will resume working tomorrow.
1319580857 2011-10-24 Salt Water Injection Well No Violations Inspection revealed that well is in operation and is gravity fed only at this time, noted that company owned van truck was unloading at facility during my inspection and I checked his log book and every thing seemed to be in order.
1323467358 2011-12-08 Salt Water Injection Well No Violations Inspection revealed that this well is in operation and is gravity fed only at this time. It was noted that the area around the wellhead still needs additional grading or dirt removed to eliminate standing water issues. Additional soil must be added to build up the area below the tank battery dike.

Note: On site to witness company owned vacuum truck perform mini test on annulus of tubing. They pressured up to 250 psi and we monitored pressure for 15 minutes with no decline in pressure.

1329826546 2016-06-16 Salt Water Injection Well No Violations Inspection revealed that injection pump is down for repair John Hawkins company mechanic was on site repairing pump on this day of my inspection.
1334880593 2012-04-19 Salt Water Injection Well No Violations Inspection revealed that well is in operation and it was noted that annulus has loss pressure due to faulty valve, contacted owner and requested that bad valve be changed out and pressure applied to annulus he stated that he would have solvent truck get pressure applied after changing valve.
1354736489 2012-12-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that there is fresh water build up in dike area, called local vacuum truck driver to advise him that water needs to be removed from dike ASAP.
1358275699 2007-07-13 Salt Water Injection Well No Violations WELL NOW UP AND RUNNING. DALE SALING, DRIVER, AT WELL. FACILITY NEWLY REBUILT AND IS IN TOP CONDITION.
1358279637 2013-01-15 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that fresh water has built up in tank area and I called vacuum truck driver to request that they remove water in dike area.
1366289083 2013-04-16 Salt Water Injection Well No Violations On site with company rep Bill Grimm to apply positive pressure to annulus of tubing with vacuum truck equipped with pressure pump, we applied 100 psi and monitored pressure for 15 minutes with no decline in pressure.

Note: Told Mr. Grimm that we would test well on monthly intervals..

1371081824 2013-06-12 Salt Water Injection Well No Violations Inspection revealed that storage tanks have been painted since my inspection and it was noted that injection pump was in operation during my inspection.
1371855151 2013-06-17 Salt Water Injection Well No Violations On site with Jim Hawkins to witness pressure testing of annulus of tubing they pressured up to 720 psi and we monitored pressure and it declined to 90 psi within 11 min which indicated they have a leaking packer, instructed owner to stop using well and get service machine lined up to replace faulty packer.
1373669344 2013-07-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that one Jayhawk Water Services truck was unloading at facility during my inspection.
1377543892 2007-05-14 Salt Water Injection Well No Violations WORK ON GOING INSIDE DIKE AREA. WALKWAYS AND LADDERS BEING RIGGED UP AND LINES BEING INSTALLED ON TANKS. APPROPRIATE PLUMBING BEING TIED IN.
1385158860 2013-11-22 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jayhawk Water Service vacuum truck was unloading at facility during my inspection.
1387224880 2013-12-16 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jayhawk Water Services vacuum truck was unloading at facility during my inspection.
1392461953 2017-06-02 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.
1395691466 2014-03-24 Salt Water Injection Well No Violations On site to witness pressure testing of annulus of tubing company owned truck pressured up to 765 psi and we monitored pressure for 15 minutes with no decline in pressure at this time.
1398714818 2014-04-28 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one Jayhawk Water Service vacuum truck was unloading at facility on the day of my inspection.
1408642387 2014-08-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jayhawk Water Service vacuum truck was unloading at the facility during my inspection.
1415450868 2014-11-06 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one J-Hawk Water Service vacuum truck was unloading at the facility during my inspection.
1420398019 2013-07-26 Salt Water Injection Well No Violations On site to witness Knox Energy release packer and remove from well they suspect that packer has lost integrity ,once packer was removed from well they shut down for the weekend, planning on starting rebuilt packer in hole on 7/29/13.

Note:Well flowed back the entire time we pulled packer approximatly 35 bbl brine was pumped to tanks.

1421962038 2015-01-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and fresh water needs to be removed from dike area too allow for volumes in the event of tank failure.
1427771774 2015-08-10 Salt Water Injection Well No Violations Previous violations at site have been resolved well is in compliance and in operation.
1429206556 2015-04-13 Salt Water Injection Well No Violations On site to witness pressure testing of annulus of tubing, company owned vacuum truck equipped with pressure pump applied 500 psi and we monitored it for 15 minutes with no decline in pressure( TEST PASSED).

Note: Injection pump was not in operation today and dike was clean and free of water ad proper identification is properly posted.

1462551428 2015-04-02 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one J Hawk Water Service vacuum truck was unloading at the facility during my inspection.
147570442 2016-11-21 0:00 SW No Violations
1488559971 2017-02-28 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that fresh water has built up in dike area and I called company and requested that they place water into storage tanks and properly dispose of it down the wellbore.
1494851937 2017-05-12 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection and it was noted that fresh water continues to build up in dike area talked to company driver and he stated he would stay on site and pump water into storage tanks to be pumped down hole.
1499373394 2017-07-06 Salt Water Injection Well No Violations On site along with Bill Grimm of JHAWK Water Service to pressure test annulus of tubing he applied 730 psi and we monitored pressure for 15 minutes with no decline in pressure.
1504297374 2017-08-30 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and I walked flowline area to monitor for any potential leaks none were found.
1508331010 2017-10-16 Salt Water Injection Well No Violations Inspected site today and found injection pump not running and also inspected dike for compliance there was a little fresh water build up in dike approximately 1/2 barrel, containment liner appeared to be liquid tight. I was checking it in regards to complaint# 5721 filed by Leah Harper a concerned citizen.
1510327855 2017-11-08 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation and it was noted that one company owned vacuum truck was unloading during my inspection.
1511054506 2016-05-17 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and it was noted that owner has recently weedeated around storage tank area.
1514313315 2017-12-26 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection.
1533072140 2013-10-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that owner has applied stone to lease road since my last inspection.
1546909215 2019-9-24 0:00: SW No Violations
1549624150 2010-12-09 Salt Water Injection Well No Violations Inspection revealed that well is in operation and is gravity fed only at this time.

Note: Pressure needs to be applied to annulus of tubing as weather permits.

1550010625 2019-02-12 Salt Water Injection Well No Violations Received call from supervisor Ken Brown stating that the Emergency Response team received a complaint from a citizen of possible brine spill, went to site noticed that there was evidence of recent truck offloading at site ran three quantab samples of water within tank area and all readings were below safe water drinking act standards.
1564789131 2017-09-06 Salt Water Injection Well No Violations Injection pump was in operation today.
1575537221 2007-04-24 Salt Water Injection Well No Violations SALT WATER INJECTION WELL. SOD BEING LAID DOWN. FINISHING JOB. DISCUSSED WITH MIKE BOOKE PLACEMENT OF TANKS IN DIKE AREA.
1596983492 2020-8-3 0:00:0 SW No Violations
1625065992 2012-08-03 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note Area north of wellhead is still in need of proper restoration area need dirt applied and seed and mulch added to this area..

1641652062 2011-09-13 Salt Water Injection Well No Violations On site to witness rig crew finish pulling tubing. Overshot was attached. They brought out remaining fishing tool and seating the assembly. They will run packer and tubing back in hole as soon as new packer arrives on site. The well bore will then be flushed, annular inhibitor installed to back side of tubing and the casing pressure tested.
1648961236 2013-05-09 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that annulus pressure had reached zero again and I contacted operator and requested that they have pressure applied as soon as possible.
1650391719 2010-11-26 Salt Water Injection Well No Violations Inspection revealed that well is in operation, gravity fed only at this time.

Note: As weather permits you will need to apply pressure to annulus of tubing and housekeeping is needed in unloading area.

1664108821 2009-02-24 Salt Water Injection Well No Violations SWIW. UNLOADING PAD AND FACILITY IN GOOD REPAIR.
1668126558 2017-04-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
1688755877 2017-09-19 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection.
169970342 2009-4-29 0:00: SW No Violations
1715020915 2008-09-03 Salt Water Injection Well No Violations WELL BEING USED. FACILITY LOOKS WELL UPKEPT
1721429438 2016-08-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1737321544 2013-12-26 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jayhawk Water vacuum truck were unloading at facility during my inspection.

Note: Contacted owner and requested that they apply positive pressure to annulus of tubing.

1779456965 2010-10-12 Salt Water Injection Well No Violations Inspection revealed that well is in operation and is gravity fed only at this time, noted that unloading pad area is in need of a good cleaning and stone is need in driveway area.
1784455606 2007-04-23 Salt Water Injection Well No Violations SOD LAID DOWN ON DIKE WALLS.OTHE RWORK BEING DONE ON UNLOADING PAD.
1809465698 2018-06-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and I talked to company rep concerning getting positive pressure applied to annulus of tubing he stated as soon as truck was repaired they would complete task.
1825619001 2012-04-13 Salt Water Injection Well No Violations Inspection revealed that well is in operation and is in satisfactory condition, talked to owner discussing placing injection pump at site and we agreed upon pump location and what tasks would need to be performed before placing pump into operation.
1835302613 2017-01-24 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation and it appears that well is not being used much at this time.
1847895669 2017-06-13 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection.
1941875039 2010-02-01 Salt Water Injection Well No Violations Inspection revealed that well is in operation currently gravity fed only.

Noted that fresh water has built up within tank area and froze when weather breaks it will need to be removed to allow for volume in the event of tank failure.

1945824073 2013-07-25 Salt Water Injection Well No Violations Knox Energy moving rig in on site to swap out tubing and packer, stopped by site and told operator that packer was setting in compression and setting depth was noted at 5086.
1985709221 2018-01-19 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.
1996528306 2005-03-28 Salt Water Injection Well No Violations NO CHANGE IN STATUS FROM LAST INSPECTION.MIT NEEDS PERFORMED ON THIS WELL TO CHECK INTEGRITY OF PIPE.
2053977176 2013-04-08 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that owner will need to apply positive pressure to annulus of tubing as soon as weather permits access to well head.
2079205866 2011-08-09 Salt Water Injection Well No Violations Inspection revealed that well is in operation and is gravity fed only at this time ,liner in dike area needs better cover on it to prevent decay and area below dike area needs to be seeded and mulched to help prevent any erosion issues that may arise.
2085663621 2019-04-17 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection and it was noted that one J-HAWK truck was on site during my inspection.
2088374478 2015-02-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and I talked to well owner requesting that they apply positive pressure to annulus of tubing in the near future.
2088890030 2014-03-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and I walked flowline area to monitor for possible leakage.

Note: No leaks detected at this time.

2088973844 2007-08-07 Salt Water Injection Well No Violations WELL IS UP AND RUNNING. RECENTLY RE DONE. LOCATION AND TANK SITE LOOKS GOOD.
2121333805 2010-04-07 Salt Water Injection Well No Violations Inspection revealed that well is in operation called and talked to Jim Hawkins concerning applying pressure to annulus of tubing in the near future he stated as soon as it dried up enough he would send truck out to apply pressure.
221164867 2010-7-8 0:00:0 SW No Violations
268798716 2008-10-6 0:00: SW No Violations
322076186 2003-4-30 0:00: SW No Violations
342354710 2012-5-25 0:00: SW No Violations
354927079 2006-8-17 0:00: SW No Violations
359336771 2015-12-21 0:00 SW No Violations
403336074 2013-3-22 0:00: SW No Violations
467606686 2019-10-15 0:00 SW No Violations
492601825 2019-12-16 0:00 SW No Violations
512738448 2018-7-17 0:00: SW No Violations
554395372 2011-5-11 0:00: SW No Violations
569528767 2008-11-14 0:00 SW No Violations
593710393 2011-9-8 0:00:0 SW No Violations
598392296 2014-6-17 0:00: SW No Violations
620180294 2010-12-30 0:00 SW No Violations
63178784 2011-5-19 0:00: SW No Violations
654157695 2018-9-28 0:00: SW No Violations
681129476 2003-6-30 0:00: SW No Violations
710352820 2007-1-19 0:00: SW No Violations
737939379 2013-7-30 0:00: SW No Violations 8.00
755561001 2018-9-14 0:00: SW No Violations
871435545 2016-1-25 0:00: SW No Violations
87340744 2012-8-21 0:00: SW No Violations
875182491 2017-6-28 0:00: SW No Violations
896905511 2010-6-8 0:00:0 SW No Violations
897337543 2014-7-24 0:00: SW No Violations
915187015 2013-8-12 0:00: SW No Violations
916323996 2015-7-14 0:00: SW No Violations
92311010 2018-5-2 0:00:0 SW No Violations
935931782 2018-6-25 0:00: SW No Violations
954001049 2008-12-31 0:00 SW No Violations
UIC1158 1991-9-18 0:00: SW No Violations
UIC1370 1993-1-12 0:00: SW No Violations
UIC1472 1993-10-18 0:00 SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0984144885 US-OH-131312 2018-07-17 9-3-07(B) Failure to notify inspector before starting injection
1278717710 US-OH-107749 2018-06-22 9-3-07(B) Failure to notify inspector before starting injection

For data sources see[9]

References