If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-059-23604 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.9,"lon":-81.52,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Valley Township | |
Operator Name: STONEBRIDGE OPERATING CO LLC | |
Well Pad ID: | |
Farm/Lease Name: HALL P | |
License Status: Final Restoration | |
License Date: 2017-04-25 | |
Spud Date: 1985-01-05 | |
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]] | |
Final Drill Date: 1985-01-11 | |
Well Total Depth: 5423.00 ft | |
Configuration: Vertical | |
Latitude: 39.900000 | |
Longitude: -81.520000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1984-10-10 | 631 BT ENERGY CORP GeoDate 10/10/84 |
Oil and Gas | 1984-10-10 | Issued Date 10/10/84 Expired Date 4/8/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05423 Proposed Drill Depth 05423 |
Original Spud | 1985-01-06 | |
Completed | 1985-01-11 | |
Reached Total Depth | 1985-01-11 | |
Completion Report Received | 1985-03-01 | |
Change of Owner | 2007-10-12 | Operator changed from 631, BT ENERGY CORP to 2070, STONEBRIDGE OPERATING CO |
APP | 2017-04-25 | Proposed Formations:DEVONIAN SHALE-ORISKANY, Issued Date:4/25/2017, Expired Date:4/25/2019 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2018-10-10 | |
Record Last Modified | 2018-11-17 | |
Construction Permit Expires | 2019-04-25 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5257 | 5306 | 16 |
5242 | 5306 | 0 | |
1997-06-29 | 5242 | 5306 | 0 |
5257 | 5306 | 16 | |
5242 | 5306 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | FRAC;H2O,SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | BT ENERGY CORP | 0.00 | 0.00 | 365 |
1985 | BT ENERGY CORP | 400.00 | 66.00 | 365 |
1986 | BT ENERGY CORP | 400.00 | 66.00 | 365 |
1987 | BT ENERGY CORP | 9989.00 | 142.00 | 365 |
1988 | BT ENERGY CORP | 7250.00 | 225.00 | 365 |
1989 | BT ENERGY CORP | 12425.00 | 73.00 | 365 |
1990 | BT ENERGY CORP | 10253.00 | 189.00 | 365 |
1993 | BT ENERGY CORP | 393.00 | 0.00 | 365 |
1996 | BT ENERGY CORP | 0.00 | 0.00 | 7 |
1997 | BT ENERGY CORP | 0.00 | 0.00 | 7 |
1998 | STONEBRIDGE OPERATING CO LLC | 28.00 | 0.00 | 7 |
2000 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 366 |
2001 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
2002 | BT ENERGY CORP | 0.00 | 0.00 | 0 |
2003 | BT ENERGY CORP | 0.00 | 0.00 | 0 |
2004 | BT ENERGY CORP | 0.00 | 0.00 | 0 |
2005 | BT ENERGY CORP | 0.00 | 0.00 | 0 |
2006 | BT ENERGY CORP | 0.00 | 0.00 | 0 |
2007 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
2008 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
2009 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
2010 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
2011 | STONEBRIDGE OPERATING CO LLC | 76.00 | 0.00 | 0 |
2012 | STONEBRIDGE OPERATING CO LLC | 124.00 | 0.00 | 0 |
2013 | STONEBRIDGE OPERATING CO LLC | 130.00 | 0.00 | 0 |
2014 | STONEBRIDGE OPERATING CO LLC | 103.00 | 0.00 | 0 |
2015 | STONEBRIDGE OPERATING CO LLC | 56.00 | 0.00 | 0 |
2016 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
2017 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
2018 | STONEBRIDGE OPERATING CO LLC | 0.00 | 0.00 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1103761275 | 2017-12-19 0:00 | PW | No Violations | 1.20 |
-1413318711 | 2015-3-25 0:00: | PW | No Violations | 2.00 |
-1746500086 | 2016-3-8 0:00:0 | PW | No Violations | 1.50 |
-1755913664 | 2018-10-9 0:00: | PB | No Violations | 3.00 |
-1847502899 | 2016-12-8 0:00: | PW | No Violations | 2.00 |
-2135622054 | 2008-7-16 0:00: | PW | No Violations | |
-256386531 | 2018-10-30 0:00 | FR | No Violations | 0.60 |
-284821630 | 2007-9-5 0:00:0 | PW | No Violations | |
-44764935 | 2016-7-18 0:00: | PW | No Violations | 1.50 |
-534555882 | 2015-6-9 0:00:0 | PW | No Violations | 1.50 |
-585552826 | 2016-12-2 0:00: | AM | No Violations | |
-642312130 | 2014-3-13 0:00: | PW | No Violations | 1.50 |
0044764935 | 2016-07-18 | Production Wells | No Violations | On the day of my inspection following up on Complaint ID4733, Compliance Notice-1216214585 and Compliance Notice-830050945, I witnessed that there was no change in the status of the well since last inspection on April 27, 2016. The production equipment consisted of a 100 barrel tank in an earthen dike. The well was equipped with 4.5 inch casing, a concoil catcher reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line has been disconnected and plugged with no separator or salesmeter present. No identification was present and gas production was reported to the State for 2015. |
0189510909 | 2014-04-10 | Production Wells | No Violations | On the day of my inspection following up on Chiefs Order #2014-39 and NOV-830050945, I reviewed The Division of Oil and Gas production records and found them not current for the years of 2012 and 2013. The well is equipped with four and a half inch production casing and a concoil catcher, the ball valve on the four and a half inch production casing appeared to be open, the valves were closed on the sales line, the lines to the production tanks were disconnected. The top is broken on the poly brine tank and the tank spacing does not meet the SPCC thirty six inch requirement, the I.D. is now in place. |
0256386531 | 2018-10-30 | Final Restoration | No Violations | The purpose of my inspection was a status check on a final restoration. During my inspection the location had been graded, seeded, and mulched. All the production equipment has been removed and no debris have been left behind. I witnessed plugging operations on 10/10/18. Location meets final restoration requirements for Ohio Revised Code 1509.072 (B). |
0284821630 | 2007-09-05 | Production Wells | No Violations | ID REPOSTED. |
0534555882 | 2015-06-09 | Production Wells | No Violations | On the day of my inspection following up on NOV-1216214585 and NOV-830050945, I witnessed that there was no change in the status of the well since last inspection. The production equipment consisted of 1-100bbl tank in an earthen dike. The well was equipped with 4.5 inch casing, a concoil catcher reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line has been disconnected and plugged. No identification was present at the time of inspection. |
0585552826 | 2016-12-02 | Administrative Inspection | No Violations | Today, at 12:43 PM, I received a phone call from Mr. John Schneider, a Field Supervisor for Stonebridge Operating, to schedule our previously discussed meeting. We agreed to meet at 10 AM on Thursday, December 8, 2016 to inspect the Shriver #1 and P Hall #1 Wells located in Guernsey County. |
0642312130 | 2014-03-13 | Production Wells | No Violations
-39, NOV-1216214585 and NOV-830050945, I witnessed that the tank battery consisted of 2-100bbl tanks, a 50bbl brine tank, a horizontal separator, a 2 inch sales meter with a .25 inch orifice, a chart recorder with no chart. Valves were closed on the sales line. Lines to the tanks were disconnected, top is broken on the polymer brine tank and tank spacing tank does not meet the 36 inch requirement. The well is equipped with 4.5 inch casing stubbed with a 4.5 inch x 5 foot pup joint plugged with no flow line to be found. Identification is now in place. The well remains incapable of production and tank spacing still does not meet the minimum requirement. | |
0720893364 | 2014-05-22 | Production Wells | No Violations
-39, NOV-1216214585 and NOV-830050945, I witnessed that the production equipment consisted of 1-100bbl tank in an earthen dike. The well was equipped with 4.5 inch casing reduced to a new 2 inch flow line with the valve in the open position going directly to the tank 0psi was on the casing. Sales line has been disconnected and plugged. Polymer brine tank, separator and additional 100bbl tank have been removed resolving the tank spacing issue. Identification is not place at the tank or the well. | |
0911523319 | 2007-05-01 | Production Wells | Violations Noted | IDLE WELL. INCAPABLE OF PRODUCTION. LINES DISCONNECTED. NO PRODUCTION REPORTED SINCE YR. 2000 |
1078617216 | 2015-12-02 | Production Wells | No Violations | On the day of my inspection following up on NOV-1216214585 and NOV-830050945 accompanied by ODNR Inspector Joe Zollars, I witnessed that there was no change in the status of the well since last inspection. The production equipment consisted of 1-100bbl tank in an earthen dike. The well was equipped with 4.5 inch casing, a concoil catcher reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line has been disconnected and plugged with no separator or sales meter present. No identification was present at the time of inspection. |
1103761275 | 2017-12-19 | Production Wells | No Violations | On the day of my inspection accompanied by David A. Wieging Special Agent Bureau of Criminal Investigation Ohio Attorney Generals Office Environmental Enforcement Unit, following up on Complaint ID 4733, Compliance Notice-1216214585 and Compliance Notice-830050945, I witnessed that there was no change in the status of the well since last inspection on October 6, 2017. The production equipment consisted of a 100 barrel tank within an earthen dike. The well was equipped with 4.5 inch diameter casing, a casing lift reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line was disconnected and plugged with no separator or salesmeter present. No identification was present and production records were current with zero production reported to the State in 2016. A plug back permit was issued for the well on April 25, 2017 with Stonebridge proposing to have the well plugged back and producing if warranted by December 31, 2017. If plug back is not warranted the well will be plugged by December 31, 2017 and reclaimed according to ORC 1509.072B. |
1142135037 | 2017-03-27 | Production Wells | No Violations | On the day of my inspection following up on Complaint ID 4733, Compliance Notice-1216214585 and Compliance Notice-830050945, I witnessed that there was no change in the status of the well since last inspection on February 2, 2017. The production equipment consisted of a 100 barrel tank within an earthen dike. The well was equipped with 4.5 inch diameter casing, a casing lift reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line was disconnected and plugged with no separator or salesmeter present. No identification was present and gas production was reported to the State for 2015. No proposal from Stonebridge has been received for resolving the Compliance Notice. |
1207848330 | 2018-03-12 | Production Wells | No Violations | On the day of my inspection following up on Compliance Notice-1354197659 and complaint ID 4766, I witnessed that there was no change in the status of the well since last inspection on December 19, 2017. The production equipment consisted of a 100 barrel tank, a disconnected concrete vault, a horizontal separator and a 2 inch salesmeter with a .75 inch orifice and a chart recorder with no chart present. Valves were closed on the sales line. The well was equipped with 4.5 inch diameter casing, 2.375 inch diameter tubing, a plunger lift system and the valves were closed on the flow line and on the casing at the well head. Identification was posted on the tank and gas production was reported to the State for 2016. A plug back permit was issued for the well on April 25, 2017 with Stonebridge proposing to have the well plugged back and producing if warranted by June 30, 2018. If plug back is not warranted the well will be plugged by June 30, 2018 and reclaimed according to ORC 1509.072B. |
1216214585 | 2008-07-16 | Production Wells | Violations Noted | WELL APPEARS TO BE IDLE. ALL VALVES SHUT IN. NO PRODUCTION SINCE YR. 20000 |
1403191907 | 2014-06-18 | Production Wells | No Violations | Prior to my inspection, I received a phone call from Rocky King the Administrator for the South East Region Division of Oil and Gas informing me of a complaint call on the well listed above. My inspection at the well site revealed the well is equipped with four and a half inch production casing / ball type gate valve with a steel two inch flow line and two inch ball valve leading into (1) one hundred barrel production tank. All the valves were open at the well head and on the flow line, the sales line has been disconnected and plugged with a steel bull plug, gas sales have been reported to The Division of Oil and Gas for the years of 2012 and 2013, no I.D. is posted at the well site. |
1409739047 | 2017-07-06 | Production Wells | No Violations | On the day of my inspection following up on Complaint ID 4733, Compliance Notice-1216214585 and Compliance Notice-830050945, I witnessed that there was no change in the status of the well since last inspection on March 27, 2017. The production equipment consisted of a 100 barrel tank within an earthen dike. The well was equipped with 4.5 inch diameter casing, a casing lift reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line was disconnected and plugged with no separator or salesmeter present. No identification was present and production records were current with zero production reported to the State in 2016. A plug back permit was issued for the well on April 25, 2017 with Stonebridge proposing to have the well plugged back and producing if warranted by December 31, 2017. If plug back is not warranted the well will be plugged by December 31, 2017 and reclaimed according to ORC 1509.072B. |
1413318711 | 2015-03-25 | Production Wells | No Violations
-39, NOV-1216214585 and NOV-830050945, I witnessed that the production equipment consisted of 1-100bbl tank in an earthen dike. The well was equipped with 4.5 inch casing, a concoil catcher reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line has been disconnected and plugged. Photographs were taken and identification is not in place at the tank or the well. | |
1436186584 | 2015-07-06 | Production Wells | No Violations | On the day of my inspection following up on NOV-1216214585 and NOV-830050945, I witnessed that there was no change in the status of the well since last inspection. The production equipment consisted of 1-100bbl tank in an earthen dike. The well was equipped with 4.5 inch casing, a concoil catcher reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line has been disconnected and plugged with no separator or sales meter present. No identification was present at the time of inspection. |
1486043584 | 2017-02-02 | Production Wells | No Violations | On the day of my inspection following up on Complaint ID 4733, Compliance Notice-1216214585 and Compliance Notice-830050945, I witnessed that there was no change in the status of the well since last inspection on December 8, 2016. The production equipment consisted of a 100 barrel tank within an earthen dike. The well was equipped with 4.5 inch diameter casing, a casing lift reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line was disconnected and plugged with no separator or salesmeter present. No identification was present and gas production was reported to the State for 2015. No proposal from Stonebridge has been received for resolving the Compliance Notice. |
1486062969 | 2016-11-29 | Administrative Inspection | No Violations | Today, Mr. John Schneider, a Field Supervisor for Stonebridge Operating, returned my phone call from 11/28/2016. At 8:32 AM, I explained to Mr. Schneider that the Division had issued violations a few years ago on the P. Hall #1 and the Shriver #1 Wells located in Guernsey County. Inspections have shown that both wells currently remain idle. Mr. Schneider was asked if he had any interest in scheduling a meeting to inspect the wells together. Mr. Schneider agreed to meet with myself and Inspector Doug Bennett to inspect both wells. We agreed to talk again on Friday to discuss our schedules for the upcoming week. |
1528200038 | 2018-06-05 | Production Wells | No Violations | The purpose of my inspection was to follow up on a compliance notice numbered -1216214585. During my inspection the well was equipped with 4.5 inch diameter production casing and a ConCoyle casing lift system. The casing valve appeared to be in the open position and a 2 inch diameter sales line was attached to the well. The sales line is ran to the 100 barrel tank and line appeared discontinued with a solid plug at the end of the line. There was not any gas production equipment or sales meter present. No identification was located in a conspicuous space on or near the wellhead or the 100 barrel tank. Production records have been submitted with Stonebridge Operating Company reporting zeros for production throughout the years 2016 and 2017. Pictures were taken to assist this inspection. |
1539260116 | 2018-10-10 | Plug / Plug Back | No Violations
-inch tubing into 3737 feet. Cemenco pumped a 60--inch and ripped the casing at 1507 feet. The 4.5-inch diameter casing was tripped from hole. The 2.375-inch diameter tubing was tripped in hole to 1364 feet and Cemenco pumped 200-foot plug 100 feet in the 8.625-inch diameter surface casing and 100 feet out in the 7.875-inch diameter borehole. The tubing was tripped up and a 100-foot surface plug was pumped with 30 sacks of class A cement. The cement stayed at surface. The plugging of this well satisfies compliance notice -1216214585. | |
1631464389 | 2014-02-18 | Production Wells | Violations Noted | On the day of my inspection following up on NOV-1216214585, I witnessed that the tank battery consisted of 2-100bbl tanks, a 50bbl brine tank, a horizontal separator, a 2 inch sales meter with a .25 inch orifice, a chart recorder with no chart. Valves were closed on the sales line. Lines to the tanks were disconnected, top is broken on the polymer brine tank and tank spacing tank does not meet the 36 inch requirement. The well is not capable of production with only 4.5 inch casing stubbed with a 4.5 inch x 5 foot pup joint plugged with no flow line to be found. No identification was present and the production records for 2012 meet the minimum requirements. Well shall be plugged. |
1746500086 | 2016-03-08 | Production Wells | No Violations | On the day of my inspection following up on NOV-1216214585 and NOV-830050945, I witnessed that there was no change in the status of the well since last inspection on December 2, 2015. The production equipment consisted of 1-100bbl tank in an earthen dike. The well was equipped with 4.5 inch casing, a concoil catcher reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line has been disconnected and plugged with no separator or sales meter present. No identification was present at the time of inspection. |
1755913664 | 2018-10-09 | Plug / Plug Back | No Violations | On 10/8/18 Berry Well Service tripped tubing within the 4.5-inch diameter casing and Cemenco set a 400-foot bottom hole plug with 30 sacks of class A cement. Berry Well Service tripped within the 4.5- |
1847502899 | 2016-12-08 | Production Wells | No Violations | On the day of my inspection accompanied by ODNR Southeast Regional Manager Brent Bear following up on Complaint ID 4733, Compliance Notice-1216214585 and Compliance Notice-830050945, we met with Stonebridge Field Supervisor John Schneider to discuss the status of the well. Mr. Schneider stated that in the current condition of the well it could not be producing any gas. Mr. Schneider also stated that he would draft a plan to address the status of the well and submit the plan to ODNR within two weeks. Upon inspection I witnessed that there was no change in the status of the well since last inspection on September 12, 2016. The production equipment consisted of a 100 barrel tank within an earthen dike. The well was equipped with 4.5 inch casing, a concoil catcher reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line was disconnected and plugged with no separator or salesmeter present. No identification was present and gas production was reported to the State for 2015. |
189510909 | 2014-4-10 0:00: | PW | No Violations | |
1959145985 | 2016-04-27 | Production Wells | No Violations | On the day of my inspection following up on Complaint ID4733, Compliance Notice-1216214585 and Compliance Notice-830050945, I witnessed that there was no change in the status of the well since last inspection on March 8, 2016. The production equipment consisted of 1-100bbl tank in an earthen dike. The well was equipped with 4.5 inch casing, a concoil catcher reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line has been disconnected and plugged with no separator or salesmeter present. No identification was present and gas production was reported to the State for 2015. |
2078536493 | 2017-10-06 | Production Wells | No Violations | On the day of my inspection following up on Complaint ID 4733, Compliance Notice-1216214585 and Compliance Notice-830050945, I witnessed that there was no change in the status of the well since last inspection on July 6, 2017. The production equipment consisted of a 100 barrel tank within an earthen dike. The well was equipped with 4.5 inch diameter casing, a casing lift reduced to a 2 inch flow line with the valve in the open position going directly to the tank. The sales line was disconnected and plugged with no separator or salesmeter present. No identification was present and production records were current with zero production reported to the State in 2016. A plug back permit was issued for the well on April 25, 2017 with Stonebridge proposing to have the well plugged back and producing if warranted by December 31, 2017. If plug back is not warranted the well will be plugged by December 31, 2017 and reclaimed according to ORC 1509.072B. |
2135622054 | 2008-07-16 | Production Wells | No Violations | FOLLOW UP TO NOV # 1216214585 WELL APPEARS TO BE IDLE. ALL VALVES SHUT IN. NO PRODUCTION SINCE YR. 20000 |
720893364 | 2014-5-22 0:00: | PW | No Violations | 2.00 |
911523319 | 2007-5-1 0:00:0 | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0911523319 | US-OH-130266 | 2007-05-02 | Failure to restore land surface within 9 mos. (CHANGE) (REPLACE) | |
0911523319 | US-OH-130267 | 2007-05-02 | Well shall be plugged | |
1216214585 | US-OH-105658 | 2008-07-16 | Well shall be plugged | |
1631464389 | US-OH-116039 | 2014-04-10 | Failure to legibly identify well | |
1631464389 | US-OH-116040 | 2014-04-10 | Violation of tank spacing requirements | |
1631464389 | US-OH-116041 | 2014-04-10 | Unlawful method of storage or disposal of brine or other wastes |
For data sources see[9]