34-059-23920

Well Details

Well ID: 34-059-23920
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Oxford Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: BULLIONS
License Status: Producing
License Date: 2000-01-19
Spud Date: 2000-02-01
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 2000-02-09
Well Total Depth: 6021.00 ft
Configuration: Vertical
Latitude: 40.030000
Longitude: -81.320000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2000-01-19 Proposed Formations:CLINTON, Issued Date:1/19/00, Expired Date:1/18/01 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2000-02-01 RBDMS Rec
Completed 2000-02-09 RBDMS Rec
Reached Total Depth 2000-02-09 RBDMS Rec
Completion Report Received 2000-04-04 RBDMS Rec
Construction Permit Expires 2001-01-18 RBDMS Rec
Change of Owner 2009-12-14 Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-07-13 5833 5853 42
5833 5853 42
5833 5853 42

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 41630 Gal 68000 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2000 EXCO - NORTH COAST ENERGY INC 4975.00 0.00 294
2001 EXCO - NORTH COAST ENERGY INC 3491.00 0.00 294
2002 EXCO - NORTH COAST ENERGY INC 1792.00 59.00 365
2003 EXCO - NORTH COAST ENERGY INC 1821.00 0.00 365
2004 EXCO - NORTH COAST ENERGY INC 1255.00 26.00 365
2005 EXCO - NORTH COAST ENERGY INC 1234.00 0.00 365
2006 EXCO - NORTH COAST ENERGY INC 1365.00 0.00 365
2007 EXCO - NORTH COAST ENERGY INC 946.00 0.00 365
2008 EXCO - NORTH COAST ENERGY INC 856.00 0.00 366
2009 EXCO - NORTH COAST ENERGY INC 686.00 0.00 365
2010 ENERVEST OPERATING LLC 698.00 0.00 365
2011 ENERVEST OPERATING LLC 965.00 0.00 0
2012 ENERVEST OPERATING LLC 974.00 43.00 366
2013 ENERVEST OPERATING LLC 904.00 0.00 365
2014 ENERVEST OPERATING LLC 808.00 0.00 365
2015 ENERVEST OPERATING LLC 485.00 0.00 182
2016 ENERVEST OPERATING LLC 293.00 0.00 124
2017 ENERVEST OPERATING LLC 193.00 0.00 30
2018 ENERVEST OPERATING LLC 199.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2000 EXCO - NORTH COAST ENERGY INC Brine 995 294
2001 EXCO - NORTH COAST ENERGY INC Brine 219 294
2002 EXCO - NORTH COAST ENERGY INC Brine 150 365
2003 EXCO - NORTH COAST ENERGY INC Brine 102 365
2004 EXCO - NORTH COAST ENERGY INC Brine 100 365
2005 EXCO - NORTH COAST ENERGY INC Brine 50 365
2006 EXCO - NORTH COAST ENERGY INC Brine 75 365
2007 EXCO - NORTH COAST ENERGY INC Brine 50 365
2008 EXCO - NORTH COAST ENERGY INC Brine 110 366
2009 EXCO - NORTH COAST ENERGY INC Brine 57 365
2010 ENERVEST OPERATING LLC Brine 53 365
2011 ENERVEST OPERATING LLC Brine 94
2012 ENERVEST OPERATING LLC Brine 28 366
2013 ENERVEST OPERATING LLC Brine 45 365
2014 ENERVEST OPERATING LLC Brine 83 365
2015 ENERVEST OPERATING LLC Brine 0 182
2016 ENERVEST OPERATING LLC Brine 0 124
2017 ENERVEST OPERATING LLC Brine 0 30
2018 ENERVEST OPERATING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1340454270 2005-1-19 0:00: PW No Violations
-1523926674 2006-5-5 0:00:0 PW No Violations
-160818590 2020-3-18 0:00: PW No Violations 1.00
-1660582088 2008-1-16 0:00: PW No Violations
-2080631722 2016-7-26 0:00: PW No Violations 2.00
0006384575 2015-02-25 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a 100bbl tank, a horizontal separator, a drip, a 2 inch sales meter with a .75 inch orifice and a chart recorder within an earthen dike. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, a plunger lift system and domestic gas service with valves open on the tubing and 1 of 2 open on the casing supplying the domestic gas and motor valve. Identification was present and production records were current.
0049594036 2007-11-21 Production Wells No Violations STATUS CHECK
0412296192 2008-10-07 Production Wells No Violations PRODUCING WELL. ID CHANGED. NO VIOLATIONS.
0829014086 2008-12-03 Production Wells No Violations FLOW LINE REPLACED
1043247993 2003-01-22 Production Wells No Violations status check
1126874015 2005-09-16 Production Wells No Violations STATUS CHECK
1162907086 2006-11-07 Production Wells No Violations PRODUCING WELL
1289i12351 2001-04-17 Preliminary Restoration No Violations PRELIMENARY RESTORATIOM COMPLETE.
1289i12351648 2001-4-17 0:00: PL No Violations
1304104503 2007-04-05 Production Wells No Violations FLOW LINE SECTION REPLACED.
1340454270 2005-01-19 Production Wells No Violations CHECK TANKS FOR LEAKS
1495548411 2017-05-23 Production Wells No Violations
1523926674 2006-05-05 Production Wells No Violations PRODUCING WELL.
1660582088 2008-01-16 Production Wells No Violations METER BOX REPLACED, FLOW LINE LEAK REPAIRED
2080631722 2016-07-26 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a 100 barrel tank, a horizontal separator, a drip, a 2 inch sales meter with a .75 inch orifice and a chart recorder within an earthen dike. The burner tube on the 100 barrel tank has a drip which was field testing revealing a pH of 6 and a chloride level greater than 6215 parts per million. An area of 1 foot by 2 feet near the tank was contaminated. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, a plunger lift system and domestic gas service with valves open on the tubing and 1 of 2 open on the casing supplying the domestic gas and motor valve. Identification was present and production records were current. I placed call to Enervest well tender Zach Chaney and stated my findings. Mr. Chaney met me at the location and reviewed my findings. A water truck arrived, pulled remaining fluids from the tank and a plug was installed in the burner tube of the tank until it could be replaced.
2088606508 2004-08-18 Production Wells No Violations STATUS CHECK, 210 BBL.
2125589174 2009-02-03 Production Wells No Violations DOMESTIC GAS BACK TO LANDOWNERS RESIDENCESINCE LAST INSPECTION.
412296192 2008-10-7 0:00: PW No Violations
49594036 2007-11-21 0:00 PW No Violations
6384575 2015-2-25 0:00: PW No Violations 1.00
829014086 2008-12-3 0:00: PW No Violations

For data sources see[9]

References