Well Details

Well ID: 34-059-24098
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Wills Township
Operator Name: DAVID R HILL INC
Well Pad ID:
Farm/Lease Name: NEFF/COWART
License Status: Producing
License Date: 2010-01-21
Spud Date: 2010-02-02
Spud Drilling Contractor: BOWMAN DRILLING
Final Drill Date: 2010-02-12
Well Total Depth: 4010.00 ft
Configuration: Vertical
Latitude: 40.000000
Longitude: -81.380000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-09-29 Proposed Formations:CLINTON/MEDINA, Issued Date:9/29/2008, Expired Date:9/29/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2010-01-21 Proposed Formations:SQUAW THRU OHIO SHALE, Issued Date:1/21/2010, Expired Date:1/21/2011 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:ENPW
Reached Total Depth 2010-02-12
Completion Report Received 2010-11-22
Construction Permit Expires 2011-01-21
Record Last Modified 2017-10-24

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 630000 Gal 120000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 DAVID R HILL INC 6061.00 0.00 176
2011 DAVID R HILL INC 10700.00 75.00 365
2012 DAVID R HILL INC 7582.00 88.00 366
2013 DAVID R HILL INC 5706.00 82.00 365
2014 DAVID R HILL INC 4686.00 0.00 365
2015 DAVID R HILL INC 3814.00 63.00 365
2016 DAVID R HILL INC 3108.00 0.00 365
2017 DAVID R HILL INC 3782.00 0.00 365
2018 DAVID R HILL INC 4328.00 0.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 DAVID R HILL INC Brine 430 176
2011 DAVID R HILL INC Brine 1063 365
2012 DAVID R HILL INC Brine 228 366
2013 DAVID R HILL INC Brine 114 365
2014 DAVID R HILL INC Brine 82 365
2015 DAVID R HILL INC Brine 75 365
2016 DAVID R HILL INC Brine 0 365
2017 DAVID R HILL INC Brine 0 365
2018 DAVID R HILL INC Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1112105775 2013-6-24 0:00: PL No Violations 1.00
-1479794908 2020-4-24 0:00: PW No Violations 1.00
-1634672562 2010-2-1 0:00:0 DD No Violations
-1738226356 2020-2-14 0:00: PW No Violations 0.50
-441931746 2010-2-4 0:00:0 DD No Violations
-966863659 2018-5-3 0:00:0 PW No Violations 0.50
0169997489 2019-04-30 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with 8.625-inch diameter surface casing with a casing head, 4.5-inch diameter production casing with a tubing head, 2.375-inch diameter tubing, rods, and a pumping unit. Production valves were in the open position. A gauge present on the tubing read 120 pounds per square inch. The production equipment consisted of one 210-barrel tank, one 30-barrel poly tank, one drip, one vertical separator, and one sales meter. The sales meter had a 2-inch diameter sales line, .375-inch orifice plate, and chart recorder with current chart. All equipment was within an earthen dike. The identification was located on the 210-barrel tank and the production records were current.
0301978325 2015-07-17 Production Wells No Violations On the day of my inspection I witnessed the production equipment included a 210bbl tank, a 30bbl polymer brine tank, a vertical separator, a drip, a 2 inch sales meter with a .375 inch orifice and a chart recorder all within an earthen dike. The well was equipped with 8.625 inch casing, 4.5 inch casing, 2.375 inch tubing, rods and pumping unit powered by electricity with valves in the open position. Identification was present and production records were current.
0441931746 2010-02-04 Drill / Deepen / Reopen No Violations On site to witness testing of Blowout Preventer, rig crew pressured up on annulas of drill string after closing blowout preventer to400 psi and I monitored pressure for 15 min with no decline in pressure Test Passed.
0873507816 2016-07-25 Production Wells No Violations On the day of my inspection I witnessed the production equipment included a 210 barrel tank, a 30 barrel polymer brine tank, a vertical separator, a drip, a 2 inch sales meter with a .375 inch orifice and a chart recorder all within an earthen dike. The well was equipped with 8.625 inch casing, 4.5 inch casing, 2.375 inch tubing, rods and a Churchill pumping unit powered by electricity with valves in the open position. Identification was present and production records were current.
0966863659 2018-05-03 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with 8.625 inch diameter surface casing with a casing head, 4.5 inch diameter production casing with a tubing head, 2.375 inch diameter tubing, rods, and a pumping unit. Production valves were in the open position. A gauge present on the tubing read 150 pounds per square inch. The production equipment consisted of one 210 barrel tank, one 30 barrel poly tank, one drip, one vertical separator, and one sales meter. The sales meter had a 2 inch diameter sales line, .375 inch orifice plate, and chart recorder with current chart. All equipment was within an earthen dike. The identification was located on the 210 barrel tank and the production records were current.
1112105775 2013-06-24 Preliminary Restoration No Violations Everything passed according to 1509.072A.
1258743667 2009-11-20 Not Drilled No Violations Permit expired 9/29/09 Well not drilled as of this date.
1265232710 2010-02-03 Drill / Deepen / Reopen No Violations
1266617439 2010-02-19 Drill / Deepen / Reopen No Violations Total depth of well 4010 -3937 of 4.5 ran and packer set at 2290 slotted casing below packer and casing was cemented in place with 110 sacks of Class A cement.
1343751945 2012-07-31 Production Wells No Violations On the day of my inspection I found the well to capable of production, there is a pump unit at the well site, the chart shows current production, there is a separator/ drip/ chart/ brine tank/ (1) two hundred ten barrel production tank setting inside a containment dike with the I.D. posted.
1573987625 2017-03-08 Production Wells No Violations On the day of my inspection I witnessed the production equipment included a 210 barrel tank, a 30 barrel polymer brine tank, a vertical separator, a drip, a 2 inch salesmeter with a .375 inch orifice and a chart recorder all within an earthen dike. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 2.375 inch diameter tubing, rods and a Churchill pumping unit powered by electricity with valves in the open position. Identification was present and production records were current.
1634672562 2010-02-01 Drill / Deepen / Reopen No Violations Stopped by drill site to check on status of rig and check on drilling pit construction,operetor stated they would spud well tomorrow and likely set 7 on Wednesday.
169997489 2019-4-30 0:00: PW No Violations 0.30
1849369003 2019-10-17 0:00 PW No Violations 0.50
301978325 2015-7-17 0:00: PW No Violations 1.00
873507816 2016-7-25 0:00: PW No Violations 0.50

For data sources see[8]