X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-24218

Well Details

Well ID: 34-059-24218
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Knox Township
Operator Name: DEVON ENERGY PRODUCTION CO LP
Well Pad ID: US-OH-000566
Farm/Lease Name: D BRILL
License Status: Final Restoration
License Date: 2017-08-18
Spud Date: 2012-08-30
Spud Drilling Contractor: BUTCHS RATHOLE & ANCHOR SERVI
Final Drill Date:
Well Total Depth: 93.00 ft
Configuration: Vertical
Latitude: 40.120000
Longitude: -81.680000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-06-21 Proposed Formations:POINT PLEASANT, Issued Date:6/21/2012, Expired Date:6/21/2014 12:00:00 PM, Drilling unit acres:120, Proposed Well Type:OG, Proposed Well Class:EDPW
APP 2015-02-17 Proposed Formations:POINT PLEASANT, Issued Date:2/17/2015, Expired Date:2/16/2017 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
APP 2017-08-18 Proposed Formations:POINT PLEASANT, Issued Date:8/18/2017, Expired Date:8/18/2019 12:00:00 PM, Drilling unit acres:120, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2017-12-06 SET 20" CONDUCTOR ONLY-
Record Last Modified 2018-07-04 SET 20" CONDUCTOR ONLY-
Construction Permit Expires 2019-08-18 SET 20" CONDUCTOR ONLY-

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2020479266 2014-1-22 0:00: PL No Violations 0.50
-2037156620 2018-2-20 0:00: PB No Violations 1.50
-958740479 2017-9-19 0:00: DD No Violations 1.00
0290910339 2017-03-13 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed the well was equipped with 20 conductor pipe with a welded plate and a 14 inch steel mouse hole both within a 9 foot concrete cellar. Erosion channels are developing on the northeast cut slope and southwest fill slope of the pad with no activity taken place since the last inspection on July 11, 2016 with the conductor set on 8/31/12 and the drilling permit expired on 6/21/14.
0357439227 2018-05-21 Final Restoration No Violations On location today to meet with Mrs. Brill and discuss the landowner waiver that was turned into ODNR incomplete. Mrs. Brill called and stated she was unavailable to meet today. I explained to Mrs. Brill that the waiver would be mailed back to the Brill residence for completion.
0431215575 2016-02-02 Drill / Deepen / Reopen No Violations
0958740479 2017-09-19 Drill / Deepen / Reopen Violations Noted On the day of my inspection I witnessed the well was equipped with 20 inch diameter conductor pipe with a welded plate and a 14 inch diameter steel mouse hole both within a 9 foot concrete cellar. Erosion channels are present on the northeast cut slope and southwest fill slope of the pad with no activity taken place onsite since the last inspection on March 17, 2017. The conductor was set on 8/31/12 and the drilling permit expired on 6/21/14. A plug permit was issued on 8/18/17 and multiple attempts were made contacting the owner to discuss plugging of the well with no response. The well owner/operator shall submit a written plugging schedule to Doug Bennett at 5880 Memory Road Zanesville, Ohio 43701-9553 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied. The well owner/operator shall also plug the mouse hole in accordance with OAC 1501:9-11-11(A). Upon plugging the well owner/operator shall complete restoration according to ORC 1509.072(B).
0968211742 2017-12-06 Plug / Plug Back No Violations On the day of my inspection following-up on Compliance Notice- 958740479, I witnessed Nicks Well Plugging (NWP) was onsite along with Appalachian Well Surveys crane service to plug well. 1.5 inch diameter tubing was tripped inside the 20 inch diameter conductor tagging the shoe at 66 feet. NWP pumped 126 sacks of Class A cement weighing 15.6 pound per gallon from 66 feet to surface circulating cement to surface. NWP tripped 1.5 inch diameter tubing out and back in the 14 inch diameter mouse hole tagging again at 66 feet. NWP pumped 65 sacks of Class A cement weighing 15.6 pound per gallon from 66 feet to surface circulating cement to surface resolving the notice. Operator was instructed operator to cut casing off 30 inches below grade and install metal plate identifying well and reclaim according to ORC 1509.072B.
1167003385 2015-02-09 Drill / Deepen / Reopen No Violations
1269218889 2018-04-19 Plug / Plug Back No Violations I spoke with Tony Claunch with Devon Energy Production Company on 4/18/18 at 2:06 p.m. Mr. Claunch and I discussed land owner waivers and the possibility of the land owner restoring the well pad. During my inspection today the lease road and the pad had gravel surfaces. There was a small pile of debris centered in the pad.
1530534602 2018-07-02 Final Restoration No Violations The purpose of my inspection was a status check on a final restoration. During my inspection the conductor and mouse hole was found to be plugged and abandon. The pad was left empty with no production equipment, only some small steel debris centering the pad. The lease road and the pad had been left as constructed. The pad appeared to be stable with no visible slip failures or extensive erosion. Gravel had been left covering the lease road and the pad. On June 1st, 2018 a landowner waiver had been completed and signed by the land owners Danny Brill, Deborah Brill, and the company Devon Energy. The landowner waiver stated that Devon Energy is not responsible for any restoration work. As written within the Ohio Revised Code 1509.072(B) the completed waiver shall release Devon Energy from all restoration work, therefore, the location has met Final Restoration requirements.
2020479266 2014-01-22 Preliminary Restoration No Violations On the day of my inspection I witnessed that only conductor has been set on said well. Site inspection revealed no violations.
2037156620 2018-02-20 Plug / Plug Back No Violations On the day of my inspection I met with landowners Debbie, Danny and Nick Brill, Devon Energy representative John Birch and Zemba representative Troy Jones to discuss restoration requirements in ORC 1509.072B and land owner waivers.
290910339 2017-3-13 0:00: DD No Violations 1.50
357439227 2018-5-21 0:00: FR No Violations 1.00
431215575 2016-2-2 0:00:0 DD No Violations 1.50
968211742 2017-12-6 0:00: PB No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0958740479 US-OH-130957 2017-09-26 Well shall be plugged

For data sources see[3]

References