If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-059-24219 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.01,"lon":-81.46,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Center Township | |
Operator Name: DEVON ENERGY PRODUCTION CO LP | |
Well Pad ID: US-OH-000611 | |
Farm/Lease Name: THE CHUMNEY FAMILY TRUST | |
License Status: Plugged Back | |
License Date: 2012-06-22 | |
Spud Date: 2012-08-03 | |
Spud Drilling Contractor: PATTERSON DRILLING | |
Final Drill Date: 2012-10-07 | |
Well Total Depth: 7350.00 ft | |
Configuration: Vertical | |
Latitude: 40.010000 | |
Longitude: -81.460000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-06-22 | Proposed Formations: BLACK RIVER, Issued Date:6/22/2012, Expired Date:6/22/2014 12:00:00 PM, Drilling unit acres:322.95, Proposed Well Type:ST, Proposed Well Class:STRT |
Reached Total Depth | 2012-10-07 | |
Plugged Back | 2012-10-09 | |
End of Confidential Data | 2013-10-07 | |
Construction Permit Expires | 2014-06-22 | |
Record Last Modified | 2015-09-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-02-28 | 8440 | 8651 | 0 |
2013-02-28 | 11230 | 11432 | 0 |
2013-02-28 | 9680 | 9891 | 0 |
2013-02-28 | 9990 | 10201 | 0 |
2013-02-28 | 10300 | 10511 | 0 |
2013-02-28 | 8752 | 8956 | 0 |
11230 | 11432 | 0 | |
10920 | 11131 | 0 | |
10610 | 10821 | 0 | |
10300 | 10511 | 0 | |
9990 | 10201 | 0 | |
9680 | 9891 | 0 | |
9370 | 9581 | 0 | |
9060 | 9271 | 0 | |
8752 | 8956 | 0 | |
8440 | 8651 | 0 | |
8125 | 8337 | 0 | |
7820 | 8026 | 0 | |
7510 | 7511 | 0 | |
7510 | 7511 | 0 | |
2013-02-28 | 9060 | 9271 | 0 |
2013-02-28 | 7510 | 7511 | 0 |
2013-02-28 | 7820 | 8026 | 0 |
2013-02-28 | 8125 | 8337 | 0 |
2013-02-28 | 9370 | 9581 | 0 |
2013-02-28 | 10610 | 10821 | 0 |
2013-02-28 | 10920 | 11131 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 11/08/2012 | 11/08/2012 | 7086.00 | 2,958,023.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Fresh Water | Operator | 100.00 | 86.59 | ||||
SURFACTANT | ||||||||
OptiKleen-WF | Halliburton Energy Services | Concentrate | Sodium perborate tetrahydrate | 10486-00-7 | ||||
LOSURF-300 NONIONIC SURFACTANT | Halliburton Energy Services | Surfactant | Isopropanol | 67-63-0 | 60.00 | 0.04 | ||
WG-36 GELLING AGENT | Halliburton Energy Services | Gelling Agent | Guar gum | 9000-30-0 | ||||
Sand Premium | Halliburton Energy Services | Proppant | Quartz | 14808-60-7 | 100.00 | 9.96 | ||
LP-65 | Halliburton Energy Services | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 10.00 | 0.00230000 | ||
BE-9 Biocide | Halliburton Energy Services | Biocide | Tri-n-butyl tetradecyl phosphonium chloride | 81741-28-8 | 10.00 | 0.00378000 | ||
WHITE | Halliburton Energy Services | Proppant | ||||||
SSA-2 | Halliburton Energy Services | Proppant | Quartz | 14808-60-7 | 100.00 | 1.54 | ||
HAI-OS ACID INHIBITOR | Halliburton Energy Services | Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | ||||
Methanol | 67-56-1 | |||||||
FE ACID - 10 HCL | Halliburton Energy Services | Acid | Hydrochloric acid | 7647-01-0 | 30.00 | 1.63 | ||
( by mass)** ( by mass)** | ||||||||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | ||
CLA-Web | Halliburton Energy Services | Scale Inhibitor | 100.00 | 0.00 | ||||
GBW-30 BREAKER | Halliburton Energy Services | Breaker | Carbohydrates | |||||
Hemicellulase enzyme | 9012-54-8 | |||||||
SURFACTANT | Halliburton Energy Services | Surfactant | Ethoxylated nonylphenol | |||||
Solvent naphtha, petroleum, light arom | 64742-95-6 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | DEVON ENERGY PRODUCTION CO LP | 0 | 0 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | DEVON ENERGY PRODUCTION CO LP | Brine | 0 | 23 |
2013 | DEVON ENERGY PRODUCTION CO LP | Brine | 0 | 0 |
2014 | DEVON ENERGY PRODUCTION CO LP | Brine | 0 | 0 |
2017 | GEOPETRO LLC | Brine | 0 | 37 |
2018 | GEOPETRO LLC | Brine | 220 | 178 |
2019 | GEOPETRO LLC | Brine | 0 | 35 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1063289078 | 2012-8-13 0:00: | DD | No Violations | |
-1203018121 | 2017-7-19 0:00: | PW | No Violations | 2.00 |
-145460619 | 2019-7-22 0:00: | PW | No Violations | 1.00 |
-1546759323 | 2017-12-7 0:00: | PW | No Violations | 1.00 |
-1607980431 | 2018-3-8 0:00:0 | PW | No Violations | 0.70 |
-1668945642 | 2014-1-9 0:00:0 | PL | No Violations | 0.40 |
-1867334320 | 2012-10-9 0:00: | PB | No Violations | |
-28453882 | 2017-8-1 0:00:0 | PW | No Violations | 1.00 |
-399901332 | 2016-1-4 0:00:0 | PW | No Violations | 2.00 |
-407870527 | 2016-2-2 0:00:0 | PW | No Violations | 1.50 |
-439811576 | 2020-6-3 0:00:0 | PW | No Violations | 1.00 |
-53997861 | 2020-2-11 0:00: | PW | No Violations | 0.50 |
-634716425 | 2017-8-15 0:00: | PW | No Violations | 1.00 |
-978483319 | 2014-1-9 0:00:0 | PL | No Violations | 0.30 |
-983339268 | 2019-7-22 0:00: | PW | No Violations | 0.50 |
0028453882 | 2017-08-01 | Production Wells | No Violations | On the day of my inspection I Energy Services Corporation was onsite with tank dike constructed and being lined with 4 inches of gravel to be placed in the bottom. 4-400 barrel tanks will be arriving from Pennsylvania for placement later this week. |
0133303075 | 2019-03-04 | Production Wells | No Violations | The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. The production equipment consisted of one high-low separator, four 400-barrel tanks, one flare, and on sales meter. The sales meter had a 2-inch diameter sales line, 1-inch orifice plate, and a chart recorder. Production records were current and identification was present. |
0325188242 | 2017-03-08 | Production Wells | No Violations | Accompanied Guernsey County Inspector Doug Bennett, Reference his Report for further details |
0334973743 | 2015-01-22 | Production Wells | No Violations | |
0399901332 | 2016-01-04 | Production Wells | Violations Noted
-9-05 (A)(1). Owner/operator shall remove oil residue, dispose of properly and replace with clean stone in accordance with ORC 1501:9-1-07. | |
0407870527 | 2016-02-02 | Production Wells | No Violations | On the day of my inspection following up on Compliance Notice-399901332, I witnessed that ROC Service company had removed contamination and remediation was completed resolving compliance notice. |
0413283786 | 2017-03-13 | Production Wells | No Violations | On the day of my inspection I witnessed there was no change in the status of the well since the last inspection on February 2, 2016. The well was equipped GE Oil & Gas casing and production wellheads with valves in the closed position. No production equipment or flowline was present at the time of inspection. Location and wellhead were fenced, gated and locked with proper identification present at the entry and at the wellhead. |
0634716425 | 2017-08-15 | Production Wells | No Violations | On the day of my inspection I witnessed Energy Services Corporation was onsite completing tank installation. 4-400 barrel tanks have been set within a lined earthen dike. The tubing valve assembly has been removed in preparation of a plunger lift system. |
0657882819 | 2016-01-28 | Production Wells | No Violations | On the day of my inspection following up on Compliance Notice-399901332, I witnessed that no action has been taken to address the oil residue. I placed call to Ron Romanetti of ROC Service Company and he stated that they would be there on Monday to remediate and would notify upon completion. |
0978483319 | 2014-01-09 | Preliminary Restoration | No Violations | The site passed preliminary restoration according to 1509.072A. |
1063289078 | 2012-08-13 | Drill / Deepen / Reopen | No Violations | Received call from local office of possible complaint of sediment had overrun silt fence and had entered adjacent property inspected site and found work crew correcting problems with faulty silt fence and applying seed and mulch to edges of drill pad to help prevent any further problems with erosion. |
1099288609 | 2012-09-19 | Drill / Deepen / Reopen | No Violations | Inspection revealed that driller was drilling on fluid at 1175 and they should TD surface hole this evening and possibly be ready to cement it in place in the morning. |
1203018121 | 2017-07-19 | Production Wells | No Violations | On the day of my inspection I met with Geopetro LLC Field Representative Eric Brown to discuss their plans to get the well online. Geopetro plans to construct a lined dike for 4-400 barrel tanks along with a -low gas production unit and a flare. They are in talks with Mark West and Columbia Gas for possible gas sales. Additional equipment a NGL bullet tank and chiller unit would have to be set if sales would go to Columbia Gas. A discussion was held on flaring gas for oil production until the pipeline would be installed. Gauge present read 2850 pounds per square inch on the casing. Mr. Brown will be installing gauges to monitor the annulus and updated well identification to comply with OAC 1501:9-9-05 (A) (10). |
1297455121 | 2017-10-06 | Production Wells | No Violations | On the day of my inspection I witnessed Energy Services Corporation was onsite pressure testing flowlines. The plunger lift system, GP unit and flare are all in place with plans to test well tentatively beginning Monday 10/9/17. |
133303075 | 2019-3-4 0:00:0 | PW | No Violations | 1.00 |
1453306411 | 2016-01-20 | Production Wells | No Violations | On the day of my inspection following up on Compliance Notice-399901332, I witnessed a plug has been installed in the casing valve securing the wellhead with no action as of date addressing the oil residue. |
1546759323 | 2017-12-07 | Production Wells | No Violations | On the day of my inspection I witnessed the well was not in operation and was equipped with a plunger lift system with valves in the open position. Gauges present read 2700 pounds per square inch on the casing and 2000 pounds per square inch on the tubing with annular monitoring present. The production equipment included 4-400 barrel tanks within a lined earthen dike, a GP unit, 2 inch meter run with a 1.25 inch orifice and a chart recorder and flare. Eric Brown of Geopetro LLC is still trying to work out a pipeline agreement with Mark West. |
1574312883 | 2017-06-29 | Production Wells | No Violations | On the day of my inspection I witnessed that the well was transferred to Geopetro LLC on June 22, 2017 with no other change in the status of the well since the last inspection on March 13, 2017. The well was equipped GE Oil & Gas casing and production wellheads with valves in the closed position. No production equipment or flowline was present at the time of inspection. Location and wellhead were fenced, gated and locked with proper identification present at the entry and at the wellhead. |
1607002328 | 2020-2-11 0:00: | PW | No Violations | 0.60 |
1607980431 | 2018-03-08 | Production Wells | No Violations | On the day of my inspection accompanied by ODNR Inspector Ryan Armstrong, I witnessed the well was in operation producing and flaring. The well was equipped with a plunger lift system with valves in the open position. Gauges present read 1900 pounds per square inch on the casing and 1400 pounds per square inch on the tubing with annular monitoring present. The production equipment included 4-400 barrel tanks within a lined earthen dike, a GP unit, a 2 inch meter run with a 1 inch orifice and a chart recorder and flare. |
1668945642 | 2014-01-09 | Preliminary Restoration | No Violations | The site passed preliminary restoration according to 1509.072A. |
1867334320 | 2012-10-09 | Plug / Plug Back | No Violations | On site to witness plugging back of said well they drilled to a total depth of 7350 and logged well and then they ran drill string back into well to set 1200 cement plug, once cement is set up they will go back into well and then proceed to drill horizontal. |
1893208365 | 2019-10-9 0:00: | PW | No Violations | 0.30 |
2016132488 | 2012-10-21 | Drill / Deepen / Reopen | No Violations | Total depth@11,538 operator ran 11,538 of 5.5 casing and two stage cementing tool@5550 and Halliburton cemented casing in place. |
325188242 | 2017-3-8 0:00:0 | PW | No Violations | 0.70 |
334973743 | 2015-1-22 0:00: | PW | No Violations | 3.00 |
413283786 | 2017-3-13 0:00: | PW | No Violations | 1.50 |
657882819 | 2016-1-28 0:00: | PW | No Violations | 1.00 |
988067147 | 2019-8-28 0:00: | PW | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0399901332 | US-OH-124263 | 2016-02-05 | Well operation causing pollution and contamination | |
0399901332 | US-OH-124264 | 2016-02-05 | Well insufficiently equipped to prevent escape of oil and gas |
For data sources see[9]