Well Details

Well ID: 34-059-24280
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Spencer Township
Operator Name: EQT PRODUCTION COMPANY
Well Pad ID: US-OH-000766
Farm/Lease Name: DOBECK
License Status: Plugged and Abandoned
License Date: 2018-01-25
Spud Date: 2013-11-07
Spud Drilling Contractor: PI0NEER DRLG
Final Drill Date: 2014-02-17
Well Total Depth: 14295.00 ft
Configuration: Horizontal
Latitude: 39.910000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-05-10 Proposed Formations:BLACK RIVER, Issued Date:5/10/2013, Expired Date:5/10/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Reached Total Depth 2014-02-17 TEMPORARY INACTIVE REPORT RECEIVED FROM OPERATOR-
Completion Report Received 2018-01-19 TEMPORARY INACTIVE REPORT RECEIVED FROM OPERATOR-
APP 2018-01-25 Proposed Formations:POINT PLEASANT, Issued Date:1/25/2018, Expired Date:1/25/2020 12:00:00 PM, Drilling unit acres:182.47, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2018-04-16 TEMPORARY INACTIVE REPORT RECEIVED FROM OPERATOR-
Record Last Modified 2018-07-11 TEMPORARY INACTIVE REPORT RECEIVED FROM OPERATOR-
Construction Permit Expires 2020-01-25 TEMPORARY INACTIVE REPORT RECEIVED FROM OPERATOR-

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1056068606 2016-4-27 0:00: PW No Violations 0.50
-1075711234 2018-4-2 0:00:0 PB No Violations
-1076853138 2020-1-30 0:00: PB No Violations 0.10
-1079508507 2019-8-21 0:00: PB No Violations 0.50
-1138965527 2019-2-14 0:00: PB No Violations 2.90
-1208782888 2018-3-5 0:00:0 DD No Violations 0.80
-1235136142 2019-3-13 0:00: PB No Violations 0.50
-127290474 2018-11-2 0:00: PB No Violations 0.50
-1291529897 2019-7-22 0:00: PB No Violations 0.50
-1345415023 2019-11-26 0:00 PB No Violations 1.00
-1371766543 2019-5-2 0:00:0 PB No Violations 0.50
-137317968 2019-2-4 0:00:0 PB No Violations 1.30
-1460970656 2019-5-13 0:00: PB No Violations 0.40
-147134191 2019-12-19 0:00 PB No Violations 0.10
-147626047 2018-3-26 0:00: DD No Violations 1.00
-1496309288 2019-2-11 0:00: PB No Violations 4.70
-1499564974 2018-8-15 0:00: PB No Violations 1.50
-1505195548 2019-8-28 0:00: PB No Violations 0.30
-1585604491 2019-2-19 0:00: PB No Violations 6.00
-1619895269 2019-2-28 0:00: PB No Violations 4.20
-1624298176 2018-8-15 0:00: PB No Violations 1.00
-164622028 2020-1-3 0:00:0 PB No Violations 0.50
-1659773084 2019-2-13 0:00: PB No Violations 0.50
-1680821415 2019-1-24 0:00: PB No Violations 1.00
-1722148036 2018-8-27 0:00: PB No Violations 1.00
-1751018991 2018-3-29 0:00: PB No Violations 4.00
-177650330 2018-3-19 0:00: DD No Violations 1.00
-182769044 2015-4-22 0:00: DD No Violations 2.00
-1850352147 2019-4-1 0:00:0 PB No Violations 0.20
-1853090095 2019-3-21 0:00: PB No Violations 0.30
-1877474964 2019-5-17 0:00: PB No Violations 0.20
-1888073380 2018-4-5 0:00:0 PB No Violations 5.00
-1944500368 2020-10-23 0:00 PB No Violations 0.30
-1956462104 2018-4-3 0:00:0 PB No Violations 10.00
-1997217285 2018-5-31 0:00: FR No Violations 0.50
-2053475648 2019-3-6 0:00:0 PB No Violations 8.80
-2079622354 2018-7-31 0:00: PB No Violations 3.00
-2083582998 2018-3-26 0:00: DD No Violations 1.00
-2143346289 2019-7-29 0:00: PB No Violations 0.50
-2145022894 2014-9-18 0:00: PL No Violations 1.00
-21707203 2018-4-12 0:00: PB No Violations 8.00
-240606425 2019-3-8 0:00:0 PB No Violations 4.30
-283128156 2017-3-22 0:00: DD No Violations 1.50
-285678579 2020-1-9 0:00:0 PB No Violations 0.30
-287729355 2014-9-18 0:00: PL No Violations 0.10
-340353486 2020-5-28 0:00: PB No Violations 0.20
-37080971 2018-10-22 0:00 PB No Violations 0.20
-427338921 2018-3-19 0:00: DD No Violations 1.00
-495595176 2019-10-31 0:00 PB No Violations 0.70
-614706471 2019-8-6 0:00:0 PB No Violations 0.20
-639768308 2019-2-6 0:00:0 PB No Violations 8.00
-640112462 2018-8-2 0:00:0 PB No Violations 2.00
-688155226 2019-4-12 0:00: PB No Violations 0.30
-700606276 2020-6-1 0:00:0 PB No Violations 0.50
-709821081 2019-3-28 0:00: PB No Violations 0.80
-733689081 2018-3-27 0:00: PB No Violations 7.00
-754205365 2019-11-26 0:00 PB No Violations 0.20
-764836145 2019-5-2 0:00:0 PB No Violations 0.30
-787769841 2019-3-4 0:00:0 PB No Violations 3.70
-844268171 2019-3-20 0:00: PB No Violations 0.30
-879118672 2018-9-28 0:00: PB No Violations 0.40
-932114408 2017-8-1 0:00:0 DD No Violations 1.00
-932961736 2020-3-11 0:00: PB No Violations 0.20
-977490143 2019-7-29 0:00: PB No Violations 0.50
-979178216 2019-12-2 0:00: PB No Violations 0.20
-98623106 2020-3-31 0:00: PB No Violations 0.70
-992613544 2020-3-23 0:00: PB No Violations 0.30
0003314919 2018-03-30 Plug / Plug Back No Violations On the day of my inspection accompanied by ODNR Inspector Jeff Adams & Austin Gutridge, I witnessed that Conserv Incorporated was tripping 2.375 inch diameter tubing in at 2100 feet planning to set it at 6240 feet. Due to the amount of rain the circulating pit was full and no available vac trucks plugging will not re-commence until Monday.
0021707203 2018-04-12 Plug / Plug Back No Violations Conserv Incorporated rigged up the wireline truck and tripped within the 9.625 inch diameter casing with a gauge tool to evaluate the casing to see if the cast iron bridge plug could make it to the desired depth of 3160 feet. The gauge tool sat down at 2167 feet and could not descend downhole any further. The gauge tool was removed from hole and a cement bond logging tool was tripped back in hole. The tool sat down at 2167 feet and the hole was logged from there up to evaluate the cement on the backside of the 9.625 inch diameter casing. The bond log showed a cement bond from 2167 feet to surface. The decision was made to not use the cast iron bridge plug since it could not get down to 3160 feet. 2.375 inch diameter tubing was tripped within the 9.625 inch diameter casing to 3160 feet.
0033577630 2018-09-14 Plug / Plug Back No Violations The inspection is conducted as supplemental information for the plugging operations. I met with Landowner Phil Dobeck on his water well. The water well had coordinates of 39.91759, --foot difference. The plates were cut and got a measurement of 9 5/8-inch casing to 13 3/8-inch casing on the cement. It was 3 feet down. The 13 3/8-inch casing and 20-inch casing was one foot down. The measurement on the annulus of the 20 inches and 26-inch casing was down 22 inches.
0037080971 2018-10-22 Plug / Plug Back No Violations During my inspection bubbles could be seen coming up through the water in the cellar.
0076016295 2018-04-04 Plug / Plug Back No Violations Conserv Incorporated tripped within the 5.5 inch diameter casing with a sinker bar and collar locator to try and verify if the casing was parted. They tagged up at 4155 feet where the casing was shot. EQT believes that the casing was parted at that depth. Energy Fishing and Rental Services arrived on location with casing jacks. The casing jacks lifted the casing enough to remove the slips and the packing rom the casing head. The 5.5 inch diameter casing was not completely free. Conserv Incorporated tripped inside the 5.5 inch diameter casing and shot the casing with a casing cutter at 4101 feet. The shot was unsuccessful and 5.5 inch casing was not free.
0127290474 2018-11-02 Plug / Plug Back No Violations During my inspection water within the cellar of the plugged well could be seen bubbling.
0137317968 2019-02-04 Plug / Plug Back No Violations

-cone bit. The rig tripped out of the well and changed the bit to a 12 3/8-inch tri-cone and was tripping in the well.

0145741156 2019-01-14 Plug / Plug Back No Violations On the day of my inspection the rig has not moved in to the location. I called Beau Fry of EQT on the status and asked for a key to the gate.
0147626047 2018-03-26 Drill / Deepen / Reopen No Violations
0177650330 2018-03-19 Drill / Deepen / Reopen No Violations On the day of inspection I accompanied ODNR Inspector Doug Bennett. See his report for details.
0182769044 2015-04-22 Drill / Deepen / Reopen No Violations

-400bbl tanks and 140bbl within containment and a gas combustor. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. The water impoundment was securely fenced in with a life preserver at the locked gate.

0240606425 2019-03-08 Plug / Plug Back No Violations The inspection revealed that Fountain Quail rig 8(Schramm 250) was running in the well with stinger tool and 3 -
0262744824 2019-03-12 Plug / Plug Back No Violations The inspection revealed the rig was rigging down and mobbing over on the Dobeck 14. The inspection revealed that there was no bubbling around the outside or the inside of the of the 26-inch riser on the poor boy. I took a video of the area and verified there was no bubbles.
0283128156 2017-03-22 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed the well was equipped with a Cactus casing wellhead with valves in the closed position with no flowline installed. Production equipment included a sand trap, a GP Unit, a sand purge tank, 8-400 barrel tanks, 140 barrel tank and a 100 barrel purge tank all within containment and a gas combustor and will be shared with the 34059242850100 Dobeck 580014. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. Fluid present in the cellar was field tested revealing a pH of 7 and chlorides of < 33 parts per million (ppm). 6 inches of fluid was present in the tank containment and was also field tested revealing tested revealing a pH of 7 and chlorides of < 33 ppm. Upon leaving the location I met with the land owner Mr. Dobeck who stated he has had his mineral released.
0287729355 2014-09-18 Preliminary Restoration No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A
0390265689 2018-08-29 Plug / Plug Back No Violations Cellar water was bubbling on the backside of the 20 inch diameter surface casing and the 13.375 inch diameter casing head had a gauge present reading 20 pounds per square inch. Fountail Qual Rig 8 was rigged up over the well.
0427338921 2018-03-19 Drill / Deepen / Reopen No Violations On the day of my inspection accompanied by ODNR Inspector Jeff Adams, I witnessed the well was equipped with a Cactus casing wellhead with valves in the closed position. All production equipment has been disassembled and removed from location. Conserv Incorporated Rig #6 was onsite with plans to rig up and commence plugging of the well later this week.
0464986886 2018-09-26 Plug / Plug Back No Violations The inspection is conducted under plugging operations. KLX Services is rigging down their tools and Universal well services are getting ready to rig up. The plug is being placed inside the 9 5/8 casing from 450-250 feet thru 4.5-inch drill pipe at 16.60 lb./ft. Universal ran 70 sacks of gas block cement. They displaced the plug with 2 barrels of gel. Job circulated good.
0639768308 2019-02-06 Plug / Plug Back No Violations The inspection revealed that Kelly--cone. The camera being ran was owned by Marshall/ Miller & Associates. The camera was rigged up and ran into the well bore. It set down at 140 feet with an obstruction. There were no signs of bubbling on the camera run. The rig hooked up flow line and was attempting to blow air down 4.5 inch open ended drill pipe to dry hole up. The camera was rigged back up and ran to a depth of 152.8 feet with a 13- foot Kelly- bushing depth. There was no bubbling present at this depth.
0640112462 2018-08-02 Plug / Plug Back No Violations The 3-inch diameter valve on the 13.375-inch diameter intermediate casing had a valve present reading 40 pounds per square inch. When that valve was opened the rigs gas monitor alarms went off recording 30% lower explosive limit.
0661372895 2018-08-08 Plug / Plug Back No Violations During my inspection Fountain Qual Schram Rig 8 drilled out the cement plugs to a depth of 1583 feet within the 9.626 inch casing and cleaned the hole.
0684124962 2018-04-10 Plug / Plug Back No Violations During my inspection Conerv Incorporated tripped the 2.375 inch diameter tubing in hole in preparation to set a cement plug where the 5.5 inch diameter casing was shot at 3268 feet. While tripping the tubing in hole the rig experience hydraulic pump issues. The rig will be down the rest of the day for maintenance.
0688155226 2019-04-12 Plug / Plug Back No Violations The inspection revealed that the rig and equipment was off the pad. The 26- inch riser was not leaking. The company had placed concrete barriers around the well and the cellar is dry.
0709821081 2019-03-28 Plug / Plug Back No Violations The inspection revealed the well is not leaking. I was accompanied by Mike Mooreland District Supervisor for the southeast region and Rick Green and Beau Fry of EQT.
0733689081 2018-03-27 Plug / Plug Back No Violations I am on location today to witness the plugging activities for inspector Doug Bennett. Cactus Wellhead was on location to change out the wellhead before Conserv Incorporated Wireline Services set the bridge plug on the well. The plan today is to set the bridge plug at the curve, then load the hole and run a bond log on the well before pressure testing it.
0787769841 2019-03-04 Plug / Plug Back No Violations

-130 feet. The calculated displacement is at 1.84 barrels displacement and the actual is at 1.5 barrels displacement.

0792636353 2019-03-07 Plug / Plug Back No Violations The inspection revealed that Fountain rig 8 (Schramm 250) was breaking down the poor boy flow tee and looked down into the 20-inch riser and noted no bubbling present. EQT made decision to have Rig 8 rig up the 18 11/16-inch burn over shoe and trip into the 20-inch casing and tag the cement. They tagged at 105 feet. The rig is cleaning up the hole and will trip out of the well and get ready to rig the Black Hawk tools to run in with a Weatherford 20-inch cement retainer. ConServ well services pumped on the retainer and set the packer element at 3000 psi. The rig is going to sting into the retainer and place 300 psi on the top of the cement plug below the retainer and sting out. ConServ well services could not get the pressure to build with no circulation after stinging into the retainer. Once the tool is unstung then circulation was established. The decision was made to place collars on the new stinger and then place thru the retainer and try to pressure up in the morning. If not able to then pressure up, then squeeze cement there and shut down.
0821469356 2018-04-11 Plug / Plug Back No Violations During my inspection Conserv Incorporated tripped the 2.375 inch diameter tubing to 3240 feet in depth and set a class A cement plug with 11.37 barrels of cement from 3190 feet to 3240 feet. Following the cement plug the rig will shut down and wait on the cement to cure before tagging the top of the cement plug.
0859713954 2018-09-27 Plug / Plug Back No Violations Accompanied by ODNR Regional Supervisor Brent Bear, during our inspection Fountain Qual Rig 8 was on location and was being maintenanced. The 9.625 inch diameter intermediate casing was milled down to 200 feet and the rig was preparing to mill the 13.375 inch diameter intermediate casing down to 200 feet.
0879118672 2018-09-28 Plug / Plug Back No Violations

- inch casing mill job. Baker Oil tools was on the site with the milling equipment. The proposed depth is 200 feet.

0932114408 2017-08-01 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed the well was equipped with a Cactus casing wellhead with valves in the closed position with no flowline installed. Production equipment included a sand trap, a GP Unit, a sand purge tank, 8-400 barrel tanks, 140 barrel tank and a 100 barrel purge tank all within containment and a gas combustor and will be shared with the 34059242850100 Dobeck 580014. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. On July 27, 2017 I received a call from Mark Van Tyne of Pin Oak Energy who stated that Pin Oak may be acquiring the Dobeck 580015 & Dobeck 580014 from EQT. I met with the land owner Mr. Dobeck who stated he has met with Pin Oak representatives and they are in talks.
1021430936 2020-6-29 0:00: PB No Violations 0.70
1056068606 2016-04-27 Production Wells No Violations On the day of my inspection I witnessed the well the well remains in Temporary Inactive status, and equipped with a Cactus casing wellhead with valves in the closed position with no flowline installed. Production equipment included a sand trap, a GP Unit, a sand purge tank, 8-400bbl tanks and 140bbl within containment and a gas combustor and will be shared with the 34059242850100 Dobeck 580014. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. The impoundment has been closed and restored to grade with seed and mulch in place.
1075711234 2018-04-02 Plug / Plug Back No Violations
1113522164 2018-08-28 Plug / Plug Back No Violations Fountain Qual rig 8 rigged up on the well to re-plug. 4.5 inch diameter drill pipe was tripped within the 9.625-inch diameter intermediate casing. The rig was shut down for maintenance and repairs. The plan was to drill the cement plug from 1390 feet 1583 feet.
1138965527 2019-02-14 Plug / Plug Back No Violations The inspection today revealed the Fountain Quail rig 8 had run the open-- inch clear to 190 feet and then the 13 3/8 clear for 10 feet until the 9 5/8- inch casing at 200 feet which shows bubbling. I will mob to New Philly office and meet with Mike Mooreland the Southeast District Supervisor. The decision was made to set a cement retainer in the 20- inch casing. The company is blowing hole to 275 feet and looking for a finishing mill to clean the 20- inch casing for retainer placement.
1204233559 2018-09-26 Plug / Plug Back No Violations

-inch casing. KLX logging truck is on location and will be logging the 13 3/8-inch casing. The rig will run in to top of plug in the inside 9 5/8 inch and bring 200-

1208782888 2018-03-05 Drill / Deepen / Reopen No Violations Accompanied Guernsey County Inspector Doug Bennett, Reference his Report for further details
1218503105 2018-10-18 Plug / Plug Back No Violations The inspection is conducted as a follow- to the plugging operation that was completed. Phil Dobeck the landowner called on 10-17-18 and stated that there were bubbles coming out of the casing down in the cellar. Brent Bear and I went to the well and verified the bubbles were coming from the 26 in casing. The cellar contains over 1 foot of water in the bottom and the casing is full on top of the cement. I stuck a probe into the cement and found that it was hard but apparently has channeled through the cement.
1235136142 2019-03-13 Plug / Plug Back No Violations The inspection revealed that the 26-inch riser was not leaking or bubbling and the well has been plugged. The well will be left open during the drilling process on the PN 059-24285-01-00.
1299471171 2018-12-28 Plug / Plug Back No Violations

- foot from the surface with no observed oil sheen. The casing can- not be seen due to the water being so deep and murky. EQT Production Company has submitted a plan to the division to reopen to plug and abandon this well.

1383895800 2013-11-08 Casing String Witnessed No Violations
1391694894 2014-02-06 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that Pioneer Drilling Rig #70 had just set a 270 sack cement kick plug from 6101 ft. to 5500 ft. due to hole problems and were getting ready to trip back in with directional tools and drill down to 5739 ft. and begin their curve. Site inspection revealed no violations.
1447748453 2018-10-07 Plug / Plug Back No Violations

-inch diameter casing and the 13 3/8-inch diameter casing. The 13 3/8 was milled to a depth of 190 feet. The 9 5/8-inch casing was milled to a depth of 200 feet. All the casing is within the 20-inch diameter casing. Haliburton is on site rigging up and will be placing gas block cement back to surface. They will be running HalCem system of 370 sacks of cement at 1.229 yield and 15.6 lb./gallon. The job was pumped, and the rig cleaned out all the drill pipe. They then were disassembling the flow stack. There was 10.5 barrels of cement pumped to surface of returns.

1452260162 2015-12-07 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed the well the well remains in Temporary Inactive status, and equipped with a Cactus casing wellhead with valves in the closed position with no flowline installed. Production equipment included a sand trap, a GP Unit, a sand purge tank, 8-400bbl tanks and 140bbl within containment and a gas combustor and will be shared with the 34059242850100 Dobeck 580014. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. The water impoundment was securely fenced in with a life preserver at the locked gate.
145741156 2019-1-14 0:00: PB No Violations 0.20
1496309288 2019-02-11 Plug / Plug Back No Violations The inspection revealed the Fountain Quail rig 8 was completed drying up the hole and started tripping pipe out of the hole. Marshal Miller and Associates are on site to run the camera in the well bore and look for gas bubbling. There is two 1170 air packages and a booster on site. The rig was blowing down the well thru the 4.5-inch drill pipe. The camera was running in the well bore and could only get to the depth of 183 feet on the second run.
1499564974 2018-08-15 Plug / Plug Back No Violations On location today with ODNR Inspector Pat Shreve and ODNR Regional Supervisor Brent Bear to monitor gas leaks. During our inspection the well could be seen bubbling within the cellar from the backside of the 20-inch diameter surface casing. EQT bled down the gas from the 9.625 by 13.375 inch diameter annulas prior to arrival. Fountain Qual Rig 8 was in the process of rigging down and skidding over to 34059242850100.
1522253562 2018-03-28 Plug / Plug Back No Violations On the day of my inspection accompanied by ODNR Inspector Jeff Adams, we met with EQT Plugging Specialist Josh Williams and reviewed the work done yesterday witnessed by ODNR Inspector Justin Smith. Conserv Incorporated (CI) had removed the check valve, safely bled well down, set an Owen Oil Tools cast iron bridge plug at 6248 feet and successfully performed a 1500 pound per square inch pressure test for 20 minutes. Conserv Incorporated Wireline Service (CIWS) was rigged up and performed a cement bond log (CBL) on the 5.5 inch diameter production casing revealing top of cement was at 4760 feet. CIWS rigged down and moved to the 34059242850100 Dobeck 580014 to perform a CBL on the 5.5 inch diameter production casing.
1522682083 2018-04-02 Plug / Plug Back No Violations On the day of my inspection accompanied by ODNR Inspector Austin Gutridge, I witnessed that Conserv Incorporated (CI) had tripped in 2.375 inch diameter tubing to the depth 6249 feet. CI gained circulation with 10 barrels of fresh water and pumped a 500 foot 53 sack Class A bottom hole plug from 6249 feet to 5749 feet. Cement was displaced with 22.25 barrels of fresh water. CI tripped tubing out to 5649 feet and pumped 9.5 barrels of 6% gel from 5649 feet to 5225 feet. CI tripped tubing out to 5243 feet to and pumped a 350 feet 37 sack Class A Clinton plug from 5243 feet to 4893 feet. Cement was displaced with 18.9 barrels of fresh water. CI tripped tubing out and will tag plug along with shooting 5.5 inch diameter casing off tomorrow.
1522939877 2018-04-05 Plug / Plug Back No Violations On the day of my inspection I accompanied ODNR Inspector Austin Gutridge; please see his report for details.
1523014139 2018-04-06 Plug / Plug Back No Violations

-ring and tripped back in the 5.5 inch diameter casing to 3268 feet and CI Rig #6 pulled 110000. KLX successfully shot the casing and tripped out of the well. CI freed up casing and shut the well in and made preparations to lay casing down on Monday.

1523886349 2018-04-13 Plug / Plug Back No Violations Conserv Incorporated had 2.375 inch tubing at 3160 feet within the 9.625 inch casing. The hole was circulated and a 550 foot plug was pumped using class A cement from 2160 feet to 3160 feet. A 6 percent gel spacer was set from 2160 feet to 1750 feet. The tubing was pulled up to 1750 feet and a 37.9 barrel class A cement plug was pumped from 1750 feet to 1250 feet.
1533559573 2018-08-01 Plug / Plug Back No Violations During my inspection Fountain Qual Rig 8 began to skid over from 34059242850100 to prepare to drill out the surface plug. The 3-inch diameter valve on the 13.375-inch diameter intermediate casing had a valve present reading 60 pounds per square inch. When that valve was opened the rigs gas monitor alarms went off recording 19% lower explosive limit. Indicating that there was in fact gas coming from the back side of the 9.625-inch diameter second intermediate casing.
1535379250 2018-08-20 Plug / Plug Back No Violations During my inspection the 13.375 inch diameter wellhead had 28 pounds per square inch and the backside of the 20 inch diameter surface casing was bubbling though the water within the cellar.
1536100484 2018-09-04 Plug / Plug Back No Violations During my inspection Fountain Qual rig 8 was in the process of milling out a 20-foot window down to 1493 feet. The rig was not in operation during inspection. The rig crew was in the process of unplugging the flowline that plugged off with steel cuttings.
1536184667 2018-09-05 Plug / Plug Back No Violations A section of the 9.625-inch diameter intermediate casing from 1473 feet to 1493 feet was milled out with a Backer Hughes Section Mill. BJ Services rigged up on location a pumped a cement plug from 1583 feet to 1283 feet a crossed the milled section. The plug consisted of 109 sacks of class A Gas Block cement. The plug was pumped through 4.5-inch diameter drill pipe weighing 16.6 pound per foot.
1536681819 2018-09-11 Plug / Plug Back No Violations The inspection was conducted under plugging operations. Fountain Quail rig 8 was over well and was placing a composite plug from Haliburton at a depth of 609 feet inside the 9 5/8--inch casing and remove the tool and trip open ended drill pipe back in to depth of to set the 150 foot of cement plug. The cement being ran by B J Services is a gas block style cement with 56 sacks of 1.19 yield and 5.24 gallon per sack water requirement. 609-459 foot is plug interval. Good circulation was established. A sample of the slurry from the tub of the pump truck was obtained.
1538401667 2018-09-17 Plug / Plug Back No Violations The inspection was conducted under plugging operations. Fountain Quail rig 8 was over well and Baker Tool Company was onsite rigging up a mill over tool. The mill over tool would be over the 9 5/8-- over pipe and a scallop on the bottom of the tool. There may a problem with the threads on the wash-over pipe. The pipe will not screw together.
1538409634 2018-09-27 Plug / Plug Back No Violations I accompanied Oil & Gas Inspector, Austin Gutridge on this inspection. Please refer to his report for the details from this inspection.
1549296275 2019-01-25 Plug / Plug Back No Violations The inspection revealed that the 20-inch riser was welded on the casing and hooked up. The rig is repacking the top drive on the Schramm 250 rig. The rig will start in the hole after the repacking is completed.
1550840969 2019-02-21 Plug / Plug Back No Violations The inspection revealed the 20-inch cement retainer is stuck in the 20-inch casing. The tool was stuck at 50 feet and fished back up to 23 feet. The tool is stuck and will not go up or down. Fountain Quail placed 20,000 lbs. of down pressure down and 60,000 lbs. of pressure on the pull. The tool will not move. The decision was made for KLX Tool company to build an 18 5/8-inch burn over shoe with tungsten carbide welded to the casing. The piece on the retainer is cast iron and will mill up fast according to Black Hawk Tool company. Then burn down over the top set of slips. The tool should pull out. The EQT will have Fountain Quail cleanup hole with finish mill in the 20-inch casing.
1551187266 2019-02-25 Plug / Plug Back No Violations The inspection revealed the Fountain Quail Rig 8 is rigged up over the well. The 20-
1551795060 2019-02-26 Plug / Plug Back No Violations The inspection revealed that Fountain Quail rig 8 (Schramm 250) was rigged up over the well. KLX tool company has an 18 11/16--inch cement retainer from Black Hawk tool company. The burn over shoe from KLX was pulled out and the magnet was ran in to retrieve all metals. Most of the slips were retrieved back and the top ring was milled completely up. The magnet was trip out and was removed, and the rig rigged up the center spear and tripped in to the hole. The Black Hawk Cement retainer was tripped out of the hole. KLX hand noticed that the lower slips were at the 51 feet mark. KLX will bring a larger magnet to retrieve out all pieces tomorrow.
1552323846 2019-03-01 Plug / Plug Back No Violations The inspection revealed that Fountain Quail rig 8 (Schramm 250) was in running in with a 10-inch magnet to clean up the metal shavings from the well to 200 feet. Then switch over to an 8-inch magnet to go into the well.
1554293114 2019-03-05 Plug / Plug Back No Violations The Fountain Quail rig 8 (Schramm 250) is over the well and had all 4 .5 inch 16.60 lbs./foot pipe pulled out and laid on racks. The inspection revealed that there was bubbling in the 26-inch riser pipe. Universal well services were on site and were going to re-cement the previous plug. The flowline to the shaker was frozen up and would have to be chipped out.
1560778278 2019-6-17 0:00: PB No Violations 0.30
1563208548 2019-7-15 0:00: PB No Violations 0.30
1567677333 2019-9-4 0:00:0 PB No Violations 0.40
1575641346 2019-12-2 0:00: PB No Violations 1.00
1585604491 2019-02-19 Plug / Plug Back No Violations The inspection on the well revealed that the Black Hawk Tool company was on site with a cement retainer for the 20- inch diameter casing. Fountain Quail rig 8 had ran in with a reaming mill to clean up the inside of the 20--inch retainer is not mechanical set but hydraulic set with fluid pressure. From 1800-2400 psi is the pump pressure to set the tool.
1586104532 2018-04-09 Plug / Plug Back No Violations The purpose of my inspection was status check on plugging operations. During my inspection Conserv Incorporated was tripping 5.5 inch diameter production casing out of hole. The casing was shot at 3268 feet in depth.
1617822501 2018-03-05 Drill / Deepen / Reopen No Violations On the day of my inspection accompanied by ODNR Inspector Ryan Armstrong, I witnessed the well was equipped with a Cactus casing wellhead with valves in the closed position with no flowline installed. Production equipment included a sand trap, a GP Unit, a sand purge tank, 8-400 barrel tanks, 140 barrel tank and a 100 barrel purge tank all within containment and a gas combustor and will be shared with the 34059242850100 Dobeck 580014. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. A plug permit was issued on 1/25/18. I met with land owner Phil Dobeck and discussed the upcoming plugging of the wells. A call was placed to EQT Supervisor Rick Green and requested an update on when plugging will commence. Mr. Green returned my call and stated that a rig should arrive later this week and deconstruction of the production equipment should begin later today.
1619895269 2019-02-28 Plug / Plug Back No Violations

-55 feet. This is where the 20-inch cement retainer from Black Hawk got hung up and partially set. The decision was made to run in with 18 5/8 burn over shoe. The shoe gauges to 18 11/16 inch. The rig ran the tool to 190 feet. The rig soap swept the hole and was rigging up the camera for the second time. The camera was ran in the well and rotated as going down and caught a collar at 35.8 feet and verified no bubbles. Then ran into a depth of 77.8 feet at 2nd joint and verified no bubbles. Then ran to a depth of 116.7 feet at 3rd joint and no bubbling, then ran to a depth of 159 feet at 4th joint and bubbling in 4 spots at collar. The pipe could be two different weights of pipe. The depth of 175 feet revealed a cement sheath that was cleaned away from the pipe. The depth of fluid is at 183.3 and there was bubbling at the top of the fluid level.

1624298176 2018-08-15 Plug / Plug Back No Violations The inspection today was a meeting with EQT. Brent Bear and I accompanied Austin Gutridge. We had met Rick Green and Beau Fry of EQT. The Fountain Quail rig is currently over the well to monitor gas leaks. The inspection revealed the well could be seen bubbling within the cellar from the backside of the 20-inch diameter surface casing. EQT bled down the gas from the 9.625 by 13.375-inch diameter annulus prior to arrival. Fountain Qual Rig 8 was in the process of rigging down and skidding over to 34059242850100.
1625941511 2018-08-06 Plug / Plug Back No Violations During my inspection Fountain Qual Rig 8 was drilling out the surface cement plug. I spoke with EQT consultant Dave Hancock and he stated that EQT may have him drill out cement plugs within the 9.625-inch casing down to 1583 feet but that is subject to change.
1659773084 2019-02-13 Plug / Plug Back No Violations
1680821415 2019-01-24 Plug / Plug Back No Violations The day of the inspection I met with Rick Green of EQT Company and the Fountain Quail rig #8(Schram 250) has moved in over the Dobeck #15. There is a vac trailer pulling water out of the square cellars and placing the water in the 500-barrel water tank. The well is still gassing at the current time. The welders are showing up to nipple up the 20-inch casing with a 26 inch riser flow tee. Rick Green called at 15:15 pm and stated the rig should be ready to go at 12:00 noon on 1-25-19.
1702531886 2014-02-12 Drill / Deepen / Reopen No Violations On the day of my inspection, I witnessed Pioneer Rig #70 drilling the lateral bore, the current length of the lateral is 11,000 foot, my walk around inspection revealed no problems.
1717711193 2018-03-29 Plug / Plug Back No Violations On the day of my inspection accompanied by ODNR Inspector Jeff Adams & Austin Gutridge, I witnessed that Conserv Incorporated had completed rig up, removing the 5.5 inch wellhead flange to release the slips and preparing to run 2.375 inch diameter tubing for plugging commencement.
1722148036 2018-08-27 Plug / Plug Back No Violations The inspection was conducted under re-
1743917459 2019-12-9 0:00: PB No Violations 0.30
1751018991 2018-03-29 Plug / Plug Back No Violations
1759931538 2013-12-18 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that the pit has been pumped dry and equipment is on site for closure. Cellars are covered and identified. No violations.
1790375673 2019-01-29 Plug / Plug Back No Violations The inspection revealed the Fountain Quail rig 8 (Schramm 250) had drilled 90 --inch open hole in 20-inch casing with cement. The depth was at 124 feet when I left.
1850352147 2019-04-01 Plug / Plug Back No Violations The inspection revealed the well was not gassing or bubbling thru the 26-inch riser.
1853090095 2019-03-21 Plug / Plug Back No Violations The inspection revealed that the 26- inch riser showed no bubbling on the inside or the backside.
1888073380 2018-04-05 Plug / Plug Back No Violations Conserv Incorporated tripped 2.375 inch diameter tubing back in hole to attempt to set a plug a crossed the failed shot attempts. The tubing tagged up on the second shot at 4155 feet and could not make it back down to the first shot at 4465 feet. Conserv nippled up to the 2.375 inch diameter tubing and pumped 15 barrels of gel to attempt to increase the chance of getting tubing down to 4450 feet. The tubing tagged up at 4155 feet in depth. A Class A cement plug was pumped from 4155 feet to 3500 feet and the 2.375 inch diameter tubing was tripped out of hole. Accompanied by ODNR Inspector Doug Bennett.
1910465388 2019-7-18 0:00: PB No Violations 1.50
1926263455 2018-08-08 Plug / Plug Back No Violations During my inspection Fountain Qual Rig 8 drilled out the cement plugs to a depth of 1390 feet within the 9.626-inch casing and cleaned the hole.
1956462104 2018-04-03 Plug / Plug Back No Violations On the day of my inspection accompanied by ODNR Inspector Ryan Armstrong, I witnessed Conserv Incorporated (CI) nipple down the casing wellhead. Conserv Incorporated Wireline Service (CIWS) rigged up and prepared a 4.5 inch diameter casing cutter. CIWS tripped in and finding fluid level at 411 feet, tagged the Clinton plug set 4/2/18 at 4818 feet and shot the 5.5 inch diameter casing off at 4465 feet. CIWS tripped out of the casing and EQT welding contractor welded the slips to the casing. CI speared the casing and made multiple unsuccessful attempts at freeing the casing pulling 57% over string weight at 140000 pounds. Cement Bond Log was reviewed again and decision was made to cut casing again. CIWS tripped in and finding fluid level at 388 feet and shot the 5.5 inch diameter casing off at 4155 feet. CIWS tripped out of the casing and CI speared the casing and made multiple unsuccessful attempts at freeing the casing pulling 70% over string weight at 140000 pounds. Operations shut down for the day to review the data.
1997217285 2018-05-31 Final Restoration No Violations The purpose of my inspection was a status check on a final restoration. The well had been plugged and a steel identification plate was located on top of the well. I spoke with Rick Green with EQT and he stated that EQT is currently receiving bids for the restoration.
2053475648 2019-03-06 Plug / Plug Back No Violations The inspection revealed that Fountain Quail rig 8 (Schramm 250) was rigged up over the well. The rig was circulating on the well due to a fresh water system and previous freeze-ups. The rig is running in with 18 7/8 tricone bit, 4-foot sub and 6- 6-
2078913905 2018-04-16 Plug / Plug Back No Violations Conserv Incorporated pumped a 6 percent gel spacer from 1250 feet to 500 feet. The 2.375 inch tubing was pulled up 500 feet within the 9.625 inch diameter casing and pumped a 37.9 barrel class A cement plug to surface. The tubing was tripped from hole. The plug remained at surface. EQT Supervisor Rick Green stated that they would be placing a steel plate on top of the well with proper identification.
2079622354 2018-07-31 Plug / Plug Back No Violations Within the cellar bubbles could be seen coming through the rain water to surface. A water truck removed the water to locate the source of the bubbling. The bubbling was coming from the backside of the conductor and the backside of the 9.625-inch diameter casing within the 13.375-inch casing. A valve was installed and recorded 33 pounds per square inch on the 13.375-inch diameter first intermediate casing string.
2080460342 2020-2-4 0:00:0 PB No Violations 0.20
2083582998 2018-03-26 Drill / Deepen / Reopen No Violations On the day of inspection I accompanied ODNR Inspector Doug Bennett. See his report for details.
2145022894 2014-09-18 Preliminary Restoration No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A
262744824 2019-3-12 0:00: PB No Violations 0.50
28557666 2019-12-20 0:00 PB No Violations 0.20
312478325 2019-11-21 0:00 PB No Violations 0.50
3314919 2018-3-30 0:00: PB No Violations 3.00
33577630 2018-9-14 0:00: PB No Violations 1.90
367501321 2019-10-10 0:00 PB No Violations 0.50
390265689 2018-8-29 0:00: PB No Violations 2.00
464986886 2018-9-26 0:00: PB No Violations 2.00
5497143 2019-12-10 0:00 PB No Violations 0.20
621060969 2019-7-24 0:00: PB No Violations
661372895 2018-8-8 0:00:0 PB No Violations 2.00
684124962 2018-4-10 0:00: PB No Violations 5.00
69129961 2019-7-11 0:00: PB No Violations 0.20
718008533 2019-4-26 0:00: PB No Violations 0.20
76016295 2018-4-4 0:00:0 PB No Violations 9.00
783092824 2020-1-9 0:00:0 PB No Violations 0.20
792636353 2019-3-7 0:00:0 PB No Violations 10.20
821469356 2018-4-11 0:00: PB No Violations 5.00
859713954 2018-9-27 0:00: PB No Violations 1.00
971050870 2019-7-23 0:00: PB No Violations 0.50
981022822 2019-11-21 0:00 PB No Violations 0.30

For data sources see[3]