X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-24316

Well Details

Well ID: 34-059-24316
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Oxford Township
Operator Name: GULFPORT APPALACHIA LLC
Well Pad ID: US-OH-000796
Farm/Lease Name: KAREN 23-9-7
License Status: Producing
License Date: 2013-09-27
Spud Date: 2013-09-25
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2013-11-23
Well Total Depth: 16343.00 ft
Configuration: Horizontal
Latitude: 40.020000
Longitude: -81.280000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-09-20 Proposed Formations:TRENTON-BLACK RIVER, Issued Date:9/20/2013, Expired Date:9/20/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2013-09-27 Proposed Formations:POINT PLEASANT, Issued Date:9/27/2013, Expired Date:9/27/2015 12:00:00 PM, Drilling unit acres:639.69, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2013-11-23
Change of Owner 2013-12-13 Operator changed from 8756, CHESAPEAKE EXPLORATION LLC to 8799, GULFPORT ENERGY CORPORATION
Completion Report Received 2014-12-02
Construction Permit Expires 2015-09-27
Correction to Well 2015-12-18 TARGET/TAKEPOINT CHANGE PER AS-DRILLED PLAT-ALE
Record Last Modified 2017-10-24

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 12/30/2013 01/20/2014 7708 6,927,130.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FRA-407 Weatherford Friction Reducer Petroleum distillates, hydrotreated light 64742-47-8 40 0.01755 0
Water 7732-18-5 55 0.02414 0
Ammonium acetate 631-61-8 5 0.00219 0
Clean Gel Stingray Guar Gel heavy aliphatic Not Available 35 0 0
Solvent naphtha, (petroleum) 64742-96-7 65 0 0
PROCLEAN 200 U.S. Water Corossion Inhibitor Citric Acid, Food Grade 77-92-9 52 0.00118 0
Water 7732-18-5 48 0.00109 0
Entecide QG40 U.S. Water Breaker ETHANOL 64-17-5 2.8 0 0
DIDECYL DIMETHYL AMMONIUM CHLORIDE 7173-51-5 8.3 0 0
Water 7732-18-5 56.4 0 0
n-ALKYL DIMETHYL BENZYL AMMONIUM CHLORIDE 68424-85-1 5.5 0 0
GLUTARALDEHYDE 111-30-8 27 0 0
Entegrate NE 1100 U.S. Water Demulsifier Water 7732-18-5 60 0.02692 0
Ethylene/Propylene Oxide Polymer Not Available 40 0.01794 0
Entegrate FR 7170 U.S. Water Friction Reducer Alcohols (C12-16), ethoxylated 68551-12-2 3.1 0.00204 0
C12-C14 Alcohol ethoxylated 68439-50-9 3.1 0.00204 0
Ammonium chloride 12125-02-9 15 0.00989 0
Alcohols (C10-16), ethoxylated 68002-97-1 3.1 0.00204 0
Petroleum distillate hydrotreated light 64742-47-8 28 0.01847 0
Water 7732-18-5 48 0.03166 0
100 mesh Minerva/Cadiz Proppant Sand 14808-60-7 100 0.67991 0
Fresh water Stingray Carrier Water 7732-18-5 100 90.6083 0
FRA-405 Weatherford Friction Reducer Water 7732-18-5 36 0 0
Alcohol, C12-16, Ethoxilated 68551-12-2 7 0 0
Sodium Chloride 7647-14-5 10 0 0
Petroleum Distillate 64742-47-8 40 0 0
Ammonium chloride 12125-02-9 7 0 0
Citric Acid 50% Pace International Acid Water 7732-18-5 50 0.198685 0
citric acid 77-92-9 50 0.198685 0
IC-250 Stingray Corossion Inhibitor Proprietary polycarboxylic acid mixture Not Available 20 0 0
Water 7732-18-5 80 0 0
X-linker Stingray Guar Gel Water 7732-18-5 70 0 0
Ethylene Glycol Not Available 30 0 0
Per Break Stingray Breaker Ammonium Persulfate 7727-54-0 99 0 0
Entegrate SC8060 WB U.S. Water Scale Inhibitor Methyl Alcohol 67-56-1 20 0.0019 0
Water 7732-18-5 59 0.00559 0
Phosphoric Acid 7664-38-2 1 0.00009000 0
2-propenoic acid, sodium salt, polymer 37350-42-8 10 0.00095 0
Aminotrimethylene Phosphonic Acid 6419-19-8 10 0.00095 0
40/70 White Minerva/Cadiz Proppant Sand 14808-60-7 100 5.58832 0
30/50 White Minerva/Cadiz Proppant Sand 14808-60-7 100 2.84628 0
BioClear 5000 Weatherford Biocide Water 7732-18-5 95 0.02398 0
2,2-dibromo-3-nitril oprop ionam ide 10222-01-2 5 0.00126 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-01-20 H2O 15 7084 Bbl 252760 STINGRAY PRESSURE PUMPING LLC STAGE 26/26

45 SHOTS

2013-12-30 H2O 15 250459 Gal 94600 STINGRAY PRESSURE PUMPING LLC STAGE 1/26

45 SHOTS STAGE 2-25

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 GULFPORT ENERGY CORPORATION 793816 67968 262
2015 GULFPORT ENERGY CORPORATION 737054 47544 358
2016 GULFPORT ENERGY CORPORATION 586608 20296 362
2017 GULFPORT ENERGY CORPORATION 395590 8655 359
2018 GULFPORT ENERGY CORPORATION 338446 7625 360
2019 GULFPORT ENERGY CORPORATION 67147 1062 90

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 GULFPORT ENERGY CORPORATION Brine 10465 262
2015 GULFPORT ENERGY CORPORATION Brine 4811 358
2016 GULFPORT ENERGY CORPORATION Brine 4995 362
2017 GULFPORT ENERGY CORPORATION Brine 2956 359
2018 GULFPORT ENERGY CORPORATION Brine 1648 360
2019 GULFPORT ENERGY CORPORATION Brine 461 90

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1069758601 2017-2-8 0:00:0 PW No Violations 0.20
-1270443400 2020-5-20 0:00: PW No Violations 1.00
-1767337724 2013-12-13 0:00 PW No Violations
-419016332 2018-5-16 0:00: PW No Violations 0.30
-612530116 2019-1-28 0:00: PW No Violations 0.20
0242246806 2016-02-29 Production Wells No Violations On the day of my inspection I witnessed that the location was gated and locked. The production equipment included 12-400bbl tanks within containment, a vapor recovery tower, a vapor blow case, a vertical 3-phase separator, 2 compressor units, a vertical heater treater, a 50bbl sand tank within containment, a gas combustor and back-up flare stack all shared with the Karen 23-9-7 1H, Karen 23-9-7 2H and Karen 23-9-7 3H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a production tree with valves in the open position with 1000psi on the tubing and 1100psi on the casing. Annular pressure monitoring was present along with identification and production records were current.
0419016332 2018-05-16 Production Wells No Violations The purpose of my inspection was a follow up on complaint numbered 5843. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. A gauge was present reading 480 pounds per square inch on the 9.625 inch diameter intermediate casing. The production equipment consisted of one 500 barrel tank, eleven 400 barrel tanks, one 50 barrel tank, one vapor recovery tower, four sand traps, four line heaters, four gas production units, one heater treater, one compressor, one vertical vent scrubber, and two combustors. No personnel on location during inspection.
0467467938 2014-08-20 Preliminary Restoration No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according ORC 1509.072A.
0612530116 2019-01-28 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present and evaluated. The production equipment consisted of one 500-barrel tank, eleven 400-barrel tanks, one 50-barrel tank, one vapor recovery tower, four sand traps, four indirect line heaters, four vertical separators, one heater treater, one compressor, one vertical vent scrubber, and two combustors.
1069758601 2017-02-08 Production Wells No Violations On the day of my inspection I witnessed that the location was gated and locked. The production equipment included 1-500 barrel tank and 11-400 barrel tanks within containment, a vapor recovery tower, a vapor blow case, a compressor unit, a vertical heater treater, a 50 barrel sand tank within containment, a gas combustor and back-up flare stack all shared with the Karen 23-9-7 1H, Karen 23-9-7 2H and Karen 23-9-7 3H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a production tree with valves in the open position with 410 pounds per square inch on the tubing and 335 pounds per square inch on the casing with annular pressure monitoring in place. Identification was present and production records were current.
1111620122 2014-04-22 Drill / Deepen / Reopen No Violations At 5:13 PM I received a call from Chris Anderson, a consultant for Gulfport Energy. Mr. Anderson stated that a fire had occurred at the well site at 2:30 PM and that the Quaker City Fire Dept. was dispatched to put it out. I drove to the well site to photograph the damage and asses the impact. My inspection found the fire originated in a Sandex tank unit. The heat from the fire caused the containment around the tank to catch on fire. There were no indications that any fluids leaked from the tank. ECM was on site removing the remaining fluid from the Sandex tank. I instructed the company representative to remove all stone with melted plastic on it and repair the containment. I recommended that the company review their tank grounding protocols.
1384276663 2013-11-12 Drill / Deepen / Reopen No Violations On the day of my inspection, I witnessed the rig drilling, there were no spills to report.
1384883101 2013-11-19 Drill / Deepen / Reopen No Violations On the day of my inspection, I witnessed the Nomac #70 drilling rig was currently drilling the lateral in the Utica formation and projected to T.D. the hole on 11/21/2013, there are no spills to report.
1385498015 2013-11-26 Drill / Deepen / Reopen No Violations On the day of my inspection, I witnessed O-Tex Pumping LLC break circulation with 113.29 Bbls of mix water and displace 300 sacks of 50/50/ POZ Class H cement for the lead cement, then with 373.91 Bbls of mix water displace 2760 sacks of Premium H cement. I witnessed O-Tex bump the plug, the final lift pressure was 1900 lbs of pressure, the floats held and total circulation was 1128 Bbls.
1767337724 2013-12-13 Production Wells No Violations On the day of my inspection, I witnessed W. Pol Contracting making well site preparations to the pad so temporary containment can be put in place for the frac tanks and equipment, the transfer of ownership from Chesapeake to Gulfport Energy has been submitted ODNR Central Office and waiting for approval, I instructed Gulfport Energy they could do site preparation to the pad but are not to stimulate or do any down hole work to any of the wells on this pad until the transfer of ownership has been established.
1985069477 2020-10-22 0:00 PW No Violations 1.00
242246806 2016-2-29 0:00: PW No Violations 1.00
467467938 2014-8-20 0:00: PL No Violations 0.80

For data sources see[9]