X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-24443

Well Details

Well ID: 34-059-24443
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Londonderry Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001144
Farm/Lease Name: HOOP LND GR
License Status: Producing
License Date: 2017-12-27
Spud Date: 2014-11-15
Spud Drilling Contractor: HIGHLAND DRLG
Final Drill Date: 2018-03-08
Well Total Depth: 17584.00 ft
Configuration: Horizontal
Latitude: 40.160000
Longitude: -81.320000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-11-10 Proposed Formations:POINT PLEASANT, Issued Date:11/10/2014, Expired Date:11/9/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2016-10-03 Proposed Formations:POINT PLEASANT, Issued Date:10/3/2016, Expired Date:10/3/2018 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:TI
Change of Owner 2017-12-08 Operator changed from 8928, CARRIZO (UTICA) LLC to 9520, ASCENT RESOURCES UTICA LLC
APP 2017-12-27 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:12/27/2017, Expired Date:12/27/2019 12:00:00 PM, Drilling unit acres:898.204, Proposed Well Type:OG, Proposed Well Class:POOL
Record Last Modified 2018-12-18 PERMIT ISSUED FOR 6000' STRAT TEST IN PT.SASNT. ONLY DRILLED TO 1624' IN OHIO SHALE. TAI EXPIRED 10/3/2017 UPDATE STATUS PER PRODUCTION RECEIVED 12/18/18-ALE.
Construction Permit Expires 2019-12-27 PERMIT ISSUED FOR 6000' STRAT TEST IN PT.SASNT. ONLY DRILLED TO 1624' IN OHIO SHALE. TAI EXPIRED 10/3/2017 UPDATE STATUS PER PRODUCTION RECEIVED 12/18/18-ALE.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
17293 17396 0
7935 8056 0
7935 8056 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 05/20/2018 06/10/2018 7544.2 14,098,600.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 EXCELERATE PS-2 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
SAND-PREMIUM WHITE-40/70, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.376524 503542
SP BREAKER Halliburton Breaker Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 87.817 117,441,000.0
Citric acid 77-92-9 60 0.00461604 6174
Glutaraldehyde 111-30-8 30 0.00635531 8500
Crystalline silica, quartz 14808-60-7 100 11.7657 15,734,700.0
Telmer Proprietary 10 0.00265304 3549
Sodium polyacrylate 9003-04-7 1 0.000265304 355
Modified thiourea polymer Proprietary 30 0.000331122 443
Methanol 67-56-1 60 0.000691901 926
Sodium persulfate 7775-27-1 100 0.00000067 1
Acrylic acid 79-10-7 0.01 0.00000265 4
Ethanol 64-17-5 1 0.000211844 284
Hydroteated light petroleum distillate 64742-47-8 30 0.0168327 22511
Ethoxylated alcohols Proprietary 30 0.000331122 443
Ethylene glycol 107-21-1 60 0.0159182 21289
Inorganic salt Proprietary 30 0.0168327 22511
Phosphoric acid 7664-38-2 0.1 0.00002118 29
Hydrochloric acid 7647-01-0 15 0.0228556 30565.8
Fatty acids, tall oil Proprietary 30 0.000331122 443
Olefins Proprietary 5 0.000132449 178
Acrylamide acrylate polymer Proprietary 30 0.0168327 22511
Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl chlorides

68424-85-1 5 0.00105922 1417
Propargyl alcohol 107-19-7 10 0.000110374 148
Sodium sulfate 7757-82-6 0.1 0.00000000 1
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) Halliburton Proppant Listed Below Listed Below 0 0 0
SCALECHEK LP-70 Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0
FE-2A Halliburton Additive Listed Below Listed Below 0 0 0
MC B-8614 Halliburton Biocide Listed Below Listed Below 0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC 382585 143923 162
2019 ASCENT RESOURCES UTICA LLC 184723 47383 90

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC Brine 11404 162
2019 ASCENT RESOURCES UTICA LLC Brine 3586 90

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-415303150 2014-12-2 0:00: DD No Violations 8.00
0133140955 2018-03-05 Drill / Deepen / Reopen No Violations On February 28, 2018 at 14:05 I received a call from Ascent Consultant Cecil Lovell stating that they just had a Hydrogen Sulfide (H2S) alarm go off and their safety section was investigating and he would let me know of their findings. Mr. Lovell called back and stated that they were drilling at 6012 feet and H2S was detected at the half round at 10.4 parts per million on the low side and 15.6 parts per million on the high side. The H2S was not sustained and they plan on going back to drilling. I stated the H2S permit conditions which they were aware of. On the day of my inspection accompanied by ODNR Inspector Ryan Armstrong, I met with Ascent Consultant Cecil Lovell and completed walk around. Mr. Lovell stated that the H2S alarm did not go off again. Patterson UTI Drilling Rig #577 was drilling ahead in the lateral with an 8.5 inch diameter bit at 16063 feet on 11.3 pound per gallon mud with a planned total depth of 17532 feet.
0415303150 2014-12-02 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that Highlands Drilling Rig #10 drilled a 23 inch diameter hole to the depth of 484 feet and ran 454 feet of 18.625 inch 87.5#/ft. J-55 casing and had trouble removing their landing joint. Baker Hughes was on site and broke circulation, pumped 35bbls of gel and 10bbls of fresh water. Baker Hughes cemented casing with 492 sacks of Class A lead cement with 0.05% Static Free, 1% CaCl, 0.5% EC-1, 0.125#/sk. Cello Flake, 0.75gals/sk. FP-6L, 0.5% BA-10A, weighing 15.6ppg with a yield of 1.20cuft/sk. Lead cement was followed 209 sacks of Class A tail cement with 0.05% Static Free, 3% CaCl, 0.5% EC-1, 0.125#/sk. Cello Flake, 0.75gals/sk. FP-6L, and 0.5% BA-10A, weighing 15.6ppg with a yield of 1.20cuft/sk. Cement weight was verified by mud scales. Cement was displaced with 125bbls of fresh water. Good cement returns of 55bbls, plug was landed at 300psi and pressured to 864psi for 5 minutes and the floats did not hold pressured up to 850psi and shut in casing.
0730231016 2018-07-17 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead. Multiple contractors were on location preparing the pad for flow back operations. The production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, two compressors, six sand traps, six gas production units, one vertical vent scrubber, and one combustor.
0905989436 2014-11-16 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that Express Energy Services had drilled a 30 inch diameter hole to the depth of 100 feet and ran 100 feet of 24 inch conductor pipe. Express gained circulation and cemented pipe with 240 sacks Class A cement with 2% CaCl and .5#/sk. of floseal. Displaced cement with 47bbls of fresh water and had good cement returns of 15bbls to surface.
1185757928 2019-05-01 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead. Production valves were in the open position. Production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, two compressors, six sand traps, six gas production units, one vertical vent scrubber, and one combustor. Identification was located at the well, at the tank battery, and at the entry. Keystone Wireline Swabbing rig was parked on pad.
1283324848 2018-03-05 Drill / Deepen / Reopen No Violations Accompanied Guernsey County Inspector Doug Bennett, Reference his Report for further details
133140955 2018-3-5 0:00:0 DD No Violations 1.50
1430610253 2020-7-15 0:00: PW No Violations 1.00
1941380831 2016-09-21 Drill / Deepen / Reopen No Violations
2127089131 2015-04-30 Preliminary Restoration No Violations On the day of my inspection accompanied by ODNR Inspector Matt Fulk, the site passed preliminary restoration according to ORC 1509.072A.
730231016 2018-7-17 0:00: PW No Violations 0.20
905989436 2014-11-16 0:00 DD No Violations 1.50

For data sources see[9]

References