X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-24504

Well Details

Well ID: 34-059-24504
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Oxford Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001462
Farm/Lease Name: RABER E LND GR
License Status: Producing
License Date: 2017-04-21
Spud Date: 2017-05-04
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2017-07-05
Well Total Depth: 19438.00 ft
Configuration: Horizontal
Latitude: 40.080000
Longitude: -81.330000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-04-21 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:4/21/2017, Expired Date:4/21/2019 12:00:00 PM, Drilling unit acres:621.846, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2017-07-05
Correction to Well 2017-07-21 CHANGE IN UNIT SIZE AND TARGET INFORMATION. ADDED FOOTAGE INFORMATION.
Correction to Well 2017-09-08 UPDATE TARGET/TAKE PER AS-DRILLED PLAT RCVD 8/31/2017 ALE.
Completion Report Received 2019-01-18
Record Last Modified 2019-01-24
Construction Permit Expires 2019-04-21

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2019-01-23 7843 7965 0
2019-01-23 19164 19269 0
19164 19269 0
7843 7965 0
7843 7965 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 10/29/2017 12/09/2017 7641 19,963,000.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FE-2A Halliburton Additive Listed Below Listed Below 0 0 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 1.28985 2,419,040.0
SP BREAKER Halliburton Breaker Listed Below Listed Below 0 0 0
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) Halliburton Proppant Listed Below Listed Below 0 0 0
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
WG-36 GELLING AGENT Halliburton Gelling Agent Listed Below Listed Below 0 0 0
MC B-8614 Halliburton Biocide Listed Below Listed Below 0 0 0
SAND-PREMIUM WHITE-30/50, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 88.6673 166,291,000.0
FR-76 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
Modified thiourea polymer Proprietary 30 0.00028092 527
Methanol 67-56-1 60 0.00696022 13054
Crystalline silica, quartz 14808-60-7 100 10.0033 18,760,600.0
Hydrochloric acid 7647-01-0 7.5 0.0915 171605
Fatty acids, tall oil Proprietary 30 0.00028092 527
Acrylamide acrylate copolymer Proprietary 30 0.0176243 33054
Ethoxylated alcohols Proprietary 30 0.00028092 527
Sodium persulfate 7775-27-1 100 0.00000432 9
Citric acid 77-92-9 60 0.00416737 7816
Guar gum 9000-30-0 100 0.00022256 418
Phosphate of a Diamine, Sodium Salt Proprietary 30 0.00636854 11944
Glutaraldehyde 111-30-8 30 0.00639279 11990
Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl chlorides

68424-85-1 5 0.00106546 1999
Hydrotreated light petroleum distillate 64742-47-8 30 0.0176243 33054
Phosphoric acid 7664-38-2 0.1 0.00002131 40
Sodium sulfate 7757-82-6 0.1 0.00000000 1
Olefins Proprietary 5 0.000112368 212
Inorganic salt Proprietary 30 0.0176243 33054
Propargyl alcohol 107-19-7 10 0.00009364 176
Ethanol 64-17-5 1 0.000213093 400
SCALECHEK LP-50 Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0
0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC 868252 149346 273
2019 ASCENT RESOURCES UTICA LLC 216406 24325 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC Brine 27810 273
2019 ASCENT RESOURCES UTICA LLC Brine 4414 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1353232490 2020-5-26 0:00: PW No Violations 1.00
-1547190165 2018-7-6 0:00:0 PL No Violations 0.20
-1683959400 2018-5-17 0:00: PW No Violations 0.20
-327060380 2017-6-27 0:00: DD No Violations 2.00
-511838775 2019-2-7 0:00:0 PW No Violations 0.20
-519592760 2017-5-19 0:00: CS No Violations
-83500531 2017-5-4 0:00:0 CS No Violations 2.00
0083500531 2017-05-04 Casing String Witnessed No Violations On the day inspection I witnessed that Precision Rathole had drilled a 36 inch diameter hole to the depth of 100 feet, hitting water at 40 feet and ran 100 feet of 30 inch 118.65 pounds per foot conductor pipe. O-Tex Pumping LLC was onsite and performed a 200 pounds per square inch pressure test, gained circulation with 2 barrels of fresh water and cemented pipe with 330 sacks Class H cement with 1.5% Calcium Chloride, .2% X--flake weighing 15.6 pounds per gallon and a yield of 1.2 cubic foot per sack. Cement was weight was verified with pressurized mud scales and displaced to 90 feet with 74.8 barrels of fresh water with good cement returns of 20 barrels to surface. Mix water was tested revealing chlorides of 54 parts per million, pH 7 and 59 degrees.
0109595982 2017-07-03 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Nomac Drilling Rig #84 had reached total depth of 19438 feet and tripped drill pipe from the wellbore. KLX Energy Service was onsite rigging up to perform a bond log on the 9.625 inch diameter casing. Upon completion Wyoming Casing Crew will commence to running 5.5 inch diameter production casing with cement to follow.
0327060380 2017-06-27 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Nomac Drilling Rig #84 had completed their 2-stage cement job on the intermediate casing job. The casing was set at was set at 6642 feet KB. Nomac Drilling Rig #84 was drilling out the float equipment at 6547 feet. Upon completion Nomac Drilling Rig #84 will trip out and back in with a Cathedral 8.75 inch diameter bottom hole assembly to drill the curve. I met with Ascent Consultant Josh Delso completing walk around and witnessed drill out of the float collar.
0511838775 2019-02-07 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Gauges were present on all casing strings. The 13.375-inch diameter surface casing had 60 pounds per square inch and the 9.625-inch diameter intermediate had 1300 pounds per square inch. The production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and one combustor. The identification was posted at the well, tank battery, and entry. Laminated copies of the Drilling permits were posted at entry. Ascent well tender was on location along with two Wise tanker trucks that were loading produce fluids from the tank battery.
0519592760 2017-05-19 Casing String Witnessed No Violations On site to witness running and cementing of of 13.375 casing Falcon drilling drilled to 1225 of 17.5 hole and ran 1222 of casing equipped with 1-float collar and 1- guide shoe and 10-centralizers and O-Tex cemented casing in place with 1340 sacks of Class H cement and they had 69 bbl of good cement returns to surface.
109595982 2017-7-3 0:00:0 DD No Violations 1.50
1498046823 2017-06-21 Drill / Deepen / Reopen No Violations
1547190165 2018-07-06 Preliminary Restoration No Violations The purpose of my inspection was a status check on a preliminary restoration. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. The production equipment consisted of nine 400 barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and one combustor. The area effected by the pad construction has been restored with vegetation coverage. The lease road and well pad consisted of a gravel surface with no erosion issues. The location has met preliminary restoration requirements written within 1509.072 (A). The identification was posted at the well, tank battery, and entry. Laminated copies of the Drilling permits were posted at entry.
1549907620 2018-09-12 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Gauges were present on all casing strings. The 9.625-inch diameter intermediate casing had 1570 pounds per square inch and the 13.375-inch surface casing had 50 pounds per square inch. The production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and two combustors. The identification was posted at the well, tank battery, and entry. Laminated copies of the Drilling permits were posted at entry.
1683959400 2018-05-17 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. The wells on the pad are in the process of flowing back. The production equipment consisted of nine barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and one combustor.
1967777557 2017-06-19 Drill / Deepen / Reopen No Violations On the day inspection I witnessed that Nomac Drilling Rig #84 was rigging up with plans to commence drilling mid-week.

For data sources see[10]

References