If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-059-24528 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.09,"lon":-81.28,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Londonderry Township | |
Operator Name: ASCENT RESOURCES UTICA LLC | |
Well Pad ID: US-OH-001558 | |
Farm/Lease Name: BLACK RACER W LND GR | |
License Status: Producing | |
License Date: 2018-06-08 | |
Spud Date: 2018-08-12 | |
Spud Drilling Contractor: PIONEER DRILLING | |
Final Drill Date: 2018-09-10 | |
Well Total Depth: 20569.00 ft | |
Configuration: Horizontal | |
Latitude: 40.090000 | |
Longitude: -81.280000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2018-06-08 | Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:6/8/2018, Expired Date:6/7/2020 12:00:00 PM, Drilling unit acres:769.563, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2018-09-10 | |
Correction to Well | 2018-12-21 | UPDATE TAKE/TARGET PER AS-DRILLED |
Completion Report Received | 2019-05-29 | |
Record Last Modified | 2019-06-05 | |
Construction Permit Expires | 2020-06-07 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2019-06-04 | 7865 | 7986 | 0 |
2019-06-04 | 20382 | 20432 | 0 |
20382 | 20432 | 0 | |
7865 | 7986 | 0 | |
7865 | 7986 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 11/03/2018 | 11/23/2018 | 7659 | 18,454,800.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SAND-PREMIUM WHITE-40/70, BULK | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 |
Fresh Water | Operator | Base Fluid | Water | 7732-18-5 | 100 | 87.4093 | 153,913,000.0 | |
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
Methanol | 67-56-1 | 100 | 0.00638322 | 11241 | ||||
Alcohols, C12-16, ethoxylated | 68551-12-2 | 5 | 0.00275344 | 4849 | ||||
Sodium chloride | 7647-14-5 | 30 | 0.0165206 | 29091 | ||||
Sodium nitrate | 7631-99-4 | 60 | 0.0155945 | 27460 | ||||
Hydrochloric acid | 7647-01-0 | 7.5 | 0.0355528 | 62603 | ||||
Ehoxylated alcohols | Proprietary | 5 | 0.00001731 | 31 | ||||
Modified thiourea polymer | Proprietary | 30 | 0.000103869 | 183 | ||||
Phosphate of a Diamine, Sodium Salt | Proprietary | 30 | 0.00603699 | 10631 | ||||
Contains no hazardous substances
in concentrations above cut-off values according to the competent authority |
CAS Not Assigned | 0 | 0 | 0 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0165206 | 29091 | ||||
Crystalline silica, quartz | 14808-60-7 | 100 | 12.0109 | 21,149,100.0 | ||||
Propargyl alcohol | 107-19-7 | 5 | 0.00001731 | 31 | ||||
9-Octadecenamide | 93-83-4 | 5 | 0.00275344 | 4849 | ||||
Citric acid | 77-92-9 | 60 | 0.00149597 | 2635 | ||||
Ammonium chloride | 12125-02-9 | 5 | 0.00275344 | 4849 | ||||
SCALECHEK LP-50 | Halliburton | Scale Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
FDP-S1296-17 | Halliburton | Additive | Listed Below | Listed Below | 0 | 0 | 0 | |
FE-2A | Halliburton | Additive | Listed Below | Listed Below | 0 | 0 | 0 | |
LD-2850 | Multi-Chem | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
HYDROCHLORIC ACID | Halliburton | Solvent | Listed Below | Listed Below | 0 | 0 | 0 | |
MX 8-4543 | Multi-Chem | Biocide | Listed Below | Listed Below | 0 | 0 | 0 | |
Ingredients | Listed Above | Listed Above | Water | 7732-18-5 | 100 | 0.487608 | 858596 | |
MX 5-2402 | Multi-Chem | Biocide | Listed Below | Listed Below | 0 | 0 | 0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2018-11-22 | H2O | 15 | 194775 Gal | 252730 | Halliburton | |
2018-11-03 | H2O | 8 | 129102 Gal | 805600 | Halliburton |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2019 | ASCENT RESOURCES UTICA LLC | 186486 | 47966 | 75 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2019 | ASCENT RESOURCES UTICA LLC | Brine | 11183 | 75 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1003114809 | 2018-10-24 0:00 | CT | No Violations | 0.20 |
-1271599904 | 2018-9-7 0:00:0 | CS | No Violations | 0.50 |
-1514433918 | 2018-10-4 0:00: | DD | No Violations | 0.20 |
-171962837 | 2019-2-11 0:00: | PW | No Violations | 0.50 |
0018587860 | 2018-12-31 | Preliminary Restoration | No Violations | The purpose of my inspection was a status check on drill-out operations. During my inspection Fortis Derrick Rig was on location tripping the drill pipe out of hole. The rig had completed drilling out frac plugs and was preparing to run 2.875-inch diameter production tubing. I spoke with Ascent Company Man, John, and he stated that annular pressure was monitored throughout the job and is continuing to be monitored. Production equipment was being installed on the South side of the pad. Five 400-barrel tanks, one vapor recovery tower, and one combustor were partially assembled. The location meets requirements for preliminary restoration. All areas effected by pad construction have been restored. The lease road and pad consisted of a gravel surface and surrounding the location there was thick vegetation coverage. |
0171962837 | 2019-02-11 | Production Wells | No Violations | The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead. Gauges were present reading 420 pounds per square inch on the 13.375-inch diameter surface casing, 984 pounds per square inch on the 9.625-inch diameter intermediate casing, 2700 pounds per square inch on the 5.5-inch diameter production casing, and 2500 pounds per square inch on the 2.875-inch diameter production tubing. The production equipment consisted of two sand traps, two gas production units, one horizontal heater treater, three compressors, five 500-barrel tanks, one vapor recovery tower, and one combustor. The identification was located at the wellhead, tank battery, and pad entry. |
0827963260 | 2018-07-27 | Drill / Deepen / Reopen | No Violations | The purpose of my inspection was a status check on conductors. Precision Rat Hole spudded the 1H and the 3H on 7/26/18. During my inspection both conductor boreholes were at total depth of 100 feet. The borehole was 36 inches and the conductor casing was 30 inch outer diameter, 29.25 inch inner diameter, and weighed 118.65 pounds per foot. Cement job calculations were discussed with Ascent Company Man Doug Bennett and Petroset supervisor Brian Sparks. The cement job was scheduled to begin at 3:00 p.m. 7/27/18. |
1003114809 | 2018-10-24 | Completion Testing | No Violations | Status check inspection found the well drilling process complete and the well scheduled to have the 5.5 casing string pressure tested and the toe sleeve opened as soon as repairs are made to the # 3 well on the pad. 2 wells are currently present on the pad. Annular pressure monitoring is in place with gauges present at surface. |
1271599904 | 2018-09-07 | Casing String Witnessed | No Violations | Pioneer 77 reached a total measured depth of 20569 feet. During my inspection the rig was running the 5.5-inch diameter production casing. The casing that was evaluated on the pipe rack was new 5.5-inch diameter casing weighing 23 pounds per foot. |
1514433918 | 2018-10-04 | Drill / Deepen / Reopen | No Violations | Pioneer 77 has completed drilling operations and has been removed from location. The wells were equipped with a night cap awaiting completion. Contractors were on location today cleaning out tanks used for drilling and hauling the final loads of Pioneer 77 to the Miller Farms Pad Guernsey county. |
1539694364 | 2018-10-15 | Completion Testing | No Violations | During my inspection the well was equipped with a frac gate valve in the closed position. Annular pressure monitoring was present with a valve on the 13.375 inch diameter surface casing reading 0 pounds per square inch and a valve on the 9.625 inch diameter intermediate casing reading 0 pounds per square inch. The well is awaiting completion operations. |
1616405287 | 2018-08-13 | Casing String Witnessed | No Violations | The purpose of my inspection was to witness the cementing of the surface casing. During my inspection I witnessed C&J Services O-Tex Cementing rig up on location. A safety meeting was held with all personnel on location. Following the safety meeting O-Tex pumped 35 barrels of gel, 10 barrels of fresh water, 1315 sacks of class A cement, and 195 barrels for displacement. The cement was weighed in pressurized mud scales confirming the weight of 15.6 pounds per gallon. |
1740739009 | 2019-04-25 | Production Wells | No Violations | The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead. Gauges were present reading 440 pounds per square inch on the 13.375-inch diameter surface casing and 1066 pounds per square inch on the 9.625-inch diameter intermediate casing. The production equipment consisted of two sand traps, two gas production units, one horizontal heater treater, three compressors, five 500-barrel tanks, one vapor recovery tower, and one combustor. The identification was located at the wellhead, tank battery, and pad entry. |
1847984387 | 2020-7-27 0:00: | PW | No Violations | 1.00 |
18587860 | 2018-12-31 0:00 | PL | No Violations | 1.00 |
1894279114 | 2019-11-15 0:00 | PW | No Violations | 0.50 |
599788553 | 2020-2-26 0:00: | PW | No Violations | 0.10 |
827963260 | 2018-7-27 0:00: | DD | No Violations | 1.00 |
For data sources see[10]