If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-063-20356 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.06,"lon":-83.87,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Hancock | |
Municipality: Blanchard Township | |
Operator Name: FO ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: HECTOR UNIT | |
License Status: Final Restoration | |
License Date: 2017-11-14 | |
Spud Date: 2015-10-19 | |
Spud Drilling Contractor: BOB HUWER DRLG | |
Final Drill Date: 2015-11-05 | |
Well Total Depth: 1428.00 ft | |
Configuration: Vertical | |
Latitude: 41.060000 | |
Longitude: -83.870000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2015-07-16 | Proposed Formations:TRENTON THRU PRE-CAMBRIAN, Issued Date:7/16/2015, Expired Date:7/15/2017 12:00:00 PM, Drilling unit acres:25, Proposed Well Type:OG, Proposed Well Class:FWC |
Reached Total Depth | 2015-11-05 | |
Change of Owner | 2016-02-23 | Operator changed from 7626, M & M ROYALTY LTD to 9312, FO ENERGY LLC |
APP | 2017-11-14 | Proposed Formations:TRENTON, Issued Date:11/14/2017, Expired Date:11/14/2019 12:00:00 PM, Drilling unit acres:25, Proposed Well Type:OG, Proposed Well Class: |
Record Last Modified | 2017-11-21 | |
Construction Permit Expires | 2019-11-14 |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2016 | FO ENERGY LLC | 0.00 | 0.00 | 0 |
2017 | FO ENERGY LLC | 0.00 | 0.00 | 0 |
2018 | FO ENERGY LLC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2016 | FO ENERGY LLC | Brine | 0 | 0 |
2017 | FO ENERGY LLC | Brine | 0 | 0 |
2018 | FO ENERGY LLC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0947946801 | 2015-11-12 | Preliminary Restoration | No Violations | Arrived at site to find pits that were used in the drilling process, has been filled. Drilling rig is still on site and appears to be ready to move to next drilling site. |
1191079467 | 2018-05-07 | Production Wells | No Violations | Checked status of well. Received plug permit for this well and service operator has removed pumpjack from wellhead. Flow line has been removed from well area. Storage tank appears to be empty and is waiting at the road to be removed. Spoke to plugging contractor while at site and plugging operations will be completed in the near future. |
1288350320 | 2019-9-16 0:00: | PB | No Violations | |
1388296906 | 2019-7-29 0:00: | PB | No Violations | |
1445356217 | 2015-10-19 | Drill / Deepen / Reopen | No Violations | Inspected site as Bob Huwer Drilling began spudding well. |
1455654896 | 2015-10-26 | Casing String Witnessed | No Violations | Witnessed cementing surface casing. Cemented 613 feet of seven inch casing in eight and three quarter inch hole. Had good returns to surface. |
1498499758 | 2017-06-26 | Preliminary Restoration | No Violations | Preliminary restoration has been completed. Pump jack installed on well and storage tank at road. Well appears to be shut in at the present time per owner. |
1501772483 | 2017-08-03 | Preliminary Restoration | No Violations | Pumpjack is currently disconnected from well. Well currently has a 4.5 by 2 inch reducer with plug at wellhead. Gauge on wellhead reads approximately 350 PSI. Preliminary restoration has been approved. |
1517510378 | 2018-02-01 | Preliminary Restoration | No Violations | Prelimiary restoration has been completed. Pump jack has been installed on well. Operator operated well and has determined that well is not ecomonically viable and will plug well in near future. |
1551994616 | 2019-03-07 | Plug / Plug Back | No Violations | Inspected the placing and installation of the bottom plug of this well. Thirty sacks of Class A cement was installed through 1420 feet of 1.5 inch tubing. The bottom plug was installed in the 4.5 inch casing. Circulation was achieved during the plugging process. |
1562006102 | 2019-7-1 0:00:0 | PB | No Violations | |
1567704205 | 2019-3-7 0:00:0 | PB | No Violations | |
1568902122 | 2019-3-7 0:00:0 | PB | No Violations | |
235229571 | 2019-8-29 0:00: | FR | No Violations | |
947946801 | 2015-11-12 0:00 | PL | No Violations |
For data sources see[7]