{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.31,"lon":-81.26,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Harrison | |
Municipality: Franklin Township | |
Operator Name: D & D ENERGY COMPANY | |
Well Pad ID: | |
Farm/Lease Name: GALBREATH H | |
License Status: Producing | |
License Date: 2014-05-02 | |
Spud Date: 1988-10-04 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1988-10-10 | |
Well Total Depth: 5911.00 ft | |
Configuration: Vertical | |
Latitude: 40.310000 | |
Longitude: -81.260000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1988-06-24 | 182 BELDEN & BLAKE CO GeoDate 6/24/88 |
Oil and Gas | 1988-06-24 | Issued Date 6/24/88 Expired Date 6/24/89 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05911 Proposed Drill Depth 05911 |
Original Spud | 1988-10-04 | |
Completed | 1988-10-10 | |
Reached Total Depth | 1988-10-10 | |
Completion Report Received | 1988-12-23 | |
Change of Owner | 2002-08-06 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC |
Change of Owner | 2005-07-08 | Operator changed from 1966, PETROX, INC to 5660, S & S ENERGY CORPORATION |
APP | 2014-05-02 | Proposed Formations:, Issued Date:5/2/2014, Expired Date:5/1/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class: |
Change of Owner | 2015-06-02 | Operator changed from 5660, S & S ENERGY CORPORATION to 5569, D & D ENERGY COMPANY |
Construction Permit Expires | 2016-05-01 | |
Record Last Modified | 2019-06-14 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5702 | 5708 | 24 |
5702 | 5708 | 24 | |
5702 | 5708 | 24 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 96500 Gal | 80000 | FRAC:SAND/WATER |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1990 | BELDEN & BLAKE CORPORATION | 197.00 | 0.00 | 193 |
1991 | BELDEN & BLAKE CORPORATION | 828.00 | 0.00 | 365 |
1992 | BELDEN & BLAKE CORPORATION | 196.00 | 0.00 | 14 |
1995 | BELDEN & BLAKE CORPORATION | 655.00 | 0.00 | 247 |
1996 | BELDEN & BLAKE CORPORATION | 1066.00 | 0.00 | 364 |
1997 | BELDEN & BLAKE CORPORATION | 448.00 | 0.00 | 362 |
1998 | BELDEN & BLAKE CORPORATION | 193.00 | 0.00 | 310 |
1999 | BELDEN & BLAKE CORPORATION | 46.00 | 0.00 | 54 |
2000 | BELDEN & BLAKE CORPORATION | 47.00 | 0.00 | 26 |
2001 | BELDEN & BLAKE CORPORATION | 0.00 | 26.00 | 8 |
2002 | PETROX, INC | 0.00 | 0.00 | 0 |
2003 | PETROX, INC | 640.00 | 0.00 | 365 |
2004 | PETROX, INC | 1189.00 | 0.00 | 365 |
2005 | PETROX, INC | 1067.00 | 3.00 | 180 |
2006 | S & S ENERGY CORP | 988.00 | 0.00 | 365 |
2007 | S & S ENERGY CORP | 365.00 | 0.00 | 365 |
2008 | S & S ENERGY CORP | 305.00 | 0.00 | 365 |
2009 | S & S ENERGY CORP | 216.00 | 0.00 | 365 |
2010 | S & S ENERGY CORP | 40.00 | 0.00 | 365 |
2011 | S & S ENERGY CORP | 66.00 | 0.00 | 365 |
2012 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2013 | S & S ENERGY CORP | 0.00 | 6.00 | 365 |
2014 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2015 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
2016 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
2017 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
2018 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1875516062 | 2020-1-21 0:00: | PW | No Violations | 1.00 |
-2089225617 | 2020-8-24 0:00: | PW | No Violations | 1.00 |
-563572485 | 2019-8-29 0:00: | PW | No Violations | 1.00 |
-870471648 | 2015-2-3 0:00:0 | PW | No Violations | 1.50 |
0847019112 | 2017-10-30 | Production Wells | No Violations | On the day of my inspection following up on NOV 1393345390, I witnessed this is a plunger- lift system well, using 1.5 inch diameter production tubing placed inside 4.5 inch diameter production casing. The plunger is being operated by a manual valve. Production equipment for this well includes a 210 bbl. production tank, a 30 bbl. polymer brine tank, a horizontal separator, and a 2 inch diameter meter run; all placed inside an earth dike. Proper identification is in place and legible. The meter box has been removed and production records indicate that well has not sold commercial volumes of gas since 2011. Left voicemail with D and D. |
0870471648 | 2015-02-03 | Production Wells | No Violations | I am checking this well to see if it is idle. I found that the well is shut in and is not in operation. I have been in contact with Jason Scott and he advised me that he has applied for plugging permits on 5 wells. I will follow up with the Columbus office to see if a plug permit has been issued. |
1332482899 | 2018-01-10 | Production Wells | No Violations | On the day of my inspection following up on NOV 1393345390, I witnessed this plungerlift well equipped with 1.5 inch diameter tubing placed inside 4.5 inch diameter casing. Gauge of casing says 825 psi, assuming it works. The plunger is being operated by a manual valve. Production equipment for this well includes a 210 bbl. production tank, a 30 bbl. polymer brine tank, a horizontal separator, and a 2 inch diameter meter run; all placed inside an earth dike. Proper identification is in place and legible except it says petrox not D&D. Wellhead label says S&S. The meter box has been removed and production records indicate that well has not sold gas since 2012. Well is shut in except for valve to pressure gauge which is partially open. Left voicemail for D&D at provided phone in RBDMS. |
1393345390 | 2014-02-24 | Production Wells | Violations Noted | I arrived on location and found well idle. All valves at wellhead are shut and there is no chart in the meter box. Production reports show well has not been in production since 2010 at which time only 40 mcf was reported.. Within 180 days apply for a plug permit and make arrangments to plug well. |
1452617864 | 2016-01-12 | Production Wells | No Violations | On the day of my inspection following up on NOV 1393345390, I witnessed this is a plunger- lift system well, using 1.5 inch diameter production tubing placed inside 4.5 inch diameter production casing. The plunger is being operated by a manual valve. Production equipment for this well includes a 210 bbl. production tank, a 30 bbl. polymer brine tank, a horizontal separator, and a 2 inch diameter meter run; all placed inside an earth dike that measures approximately 30*40 feet at an average height of 1 foot. Proper identification is in place and legible. The meter chart and production records indicate that this well is still not in producing order and has not sold commercial volumes of gas since 2011. I will place a call to Bob Didi the owner/producer of the well in regards to the issues noted. |
1528723482 | 2018-06-11 | Production Wells | No Violations | On the day of my inspection following up on NOV 1393345390, I witnessed this plungerlift well equipped with 4.5 inch diameter casing and 1.9 inch diameter tubing. Gauge of casing says 825 psi, assuming it works. An audible leak is coming from the 4.5. Production equipment for this well includes a 210 barrel steel tank, a 30 barrel poly tank,and a horizontal separator, all placed inside an earthen dike. Proper identification is in place and legible except it says petrox not D&D. Wellhead label says S&S. The meter box has been removed and production records indicate that well has not sold gas since 2012. Well is shut in except for valve to pressure gauge which is partially open. Phone number in RBDMS is no longer in service. Plugging permit expired in 2016. |
1555422893 | 2019-04-16 | Production Wells | No Violations | On the day of my inspection following up on NOV 1393345390 to plug well, I witnessed this plunger lift well equipped with 4.5 inch diameter casing and 1.9 inch diameter tubing. Gauge on casing says 0 psi. I was unable to hear a leak during this inspection. Production equipment for this well includes a 210 barrel steel tank, a 30 barrel poly tank, and a horizontal separator, all placed inside an earthen dike. Proper identification is in place and legible except it says petrox not D&D. Wellhead label says S&S. The meter box has been removed and production records indicate that well has not sold gas since 2012. Well is shut in except for valve to pressure gauge which is partially open. Plugging permit expired in 2016. Left voicemail with Bob Ditty. |
1588465965 | 2018-12-11 | Production Wells | No Violations | On the day of my inspection following up on NOV 1393345390 to plug well, I witnessed this plunger lift well equipped with 4.5 inch diameter casing and 1.9 inch diameter tubing. Gauge on casing says 0 psi. An audible leak is coming from the 4.5. Production equipment for this well includes a 210 barrel steel tank, a 30 barrel poly tank,and a horizontal separator, all placed inside an earthen dike. Proper identification is in place and legible except it says petrox not D&D. Wellhead label says S&S. The meter box has been removed and production records indicate that well has not sold gas since 2012. Well is shut in except for valve to pressure gauge which is partially open. Plugging permit expired in 2016. Spoke with Bob Ditty of D&D energy. He is going to get signs updated. According to him he has contracts with Diversified and plans to produce this well within the next couple months. |
847019112 | 2017-10-30 0:00 | PW | No Violations | 1.00 |
909093412 | 2020-5-18 0:00: | PW | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1393345390 | US-OH-111619 | 2016-07-26 | NONE | Well shall be plugged |
For data sources see[9]