If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-067-20863 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.32,"lon":-81.23,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Harrison | |
Municipality: Franklin Township | |
Operator Name: D & D ENERGY COMPANY | |
Well Pad ID: | |
Farm/Lease Name: COOK | |
License Status: Producing | |
License Date: 1988-08-03 | |
Spud Date: 1988-10-31 | |
Spud Drilling Contractor: ADVENT DRLG | |
Final Drill Date: 1988-11-05 | |
Well Total Depth: 6020.00 ft | |
Configuration: Vertical | |
Latitude: 40.320000 | |
Longitude: -81.230000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1988-08-03 | 182 BELDEN & BLAKE CO GeoDate 8/3/88 |
Oil and Gas | 1988-08-03 | Issued Date 8/3/88 Expired Date 8/3/89 Acres 0040880 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 06020 Proposed Drill Depth 06020 |
Original Spud | 1988-10-31 | |
Completed | 1988-11-05 | |
Reached Total Depth | 1988-11-05 | |
Completion Report Received | 1989-01-19 | |
Construction Permit Expires | 1989-08-03 | |
Change of Owner | 2002-08-06 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC |
Change of Owner | 2005-07-08 | Operator changed from 1966, PETROX, INC to 5660, S & S ENERGY CORPORATION |
Change of Owner | 2015-06-02 | Operator changed from 5660, S & S ENERGY CORPORATION to 5569, D & D ENERGY COMPANY |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5749 | 5874 | 0 |
5749 | 5874 | 0 | |
2006-09-11 | 5785 | 5859 | 40 |
5785 | 5859 | 40 | |
5749 | 5874 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 76450 Gal | 80000 | FRAC:WATER/SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1991 | BELDEN & BLAKE CORPORATION | 0.00 | 0.00 | 365 |
1992 | BELDEN & BLAKE CORPORATION | 7255.00 | 326.00 | 222 |
1993 | BELDEN & BLAKE CORPORATION | 3766.00 | 115.00 | 271 |
1994 | BELDEN & BLAKE CORPORATION | 2730.00 | 0.00 | 326 |
1995 | BELDEN & BLAKE CORPORATION | 1748.00 | 94.00 | 305 |
1996 | BELDEN & BLAKE CORPORATION | 2473.00 | 0.00 | 268 |
1997 | BELDEN & BLAKE CORPORATION | 2506.00 | 0.00 | 344 |
1998 | BELDEN & BLAKE CORPORATION | 1839.00 | 0.00 | 276 |
1999 | BELDEN & BLAKE CORPORATION | 1099.00 | 74.00 | 153 |
2000 | BELDEN & BLAKE CORPORATION | 957.00 | 0.00 | 313 |
2001 | BELDEN & BLAKE CORPORATION | 435.00 | 0.00 | 357 |
2002 | PETROX, INC | 983.00 | 0.00 | 84 |
2003 | PETROX, INC | 1000.00 | 0.00 | 365 |
2004 | PETROX, INC | 440.00 | 0.00 | 365 |
2005 | PETROX, INC | 357.00 | 0.00 | 180 |
2006 | S & S ENERGY CORP | 396.00 | 0.00 | 365 |
2007 | S & S ENERGY CORP | 572.00 | 0.00 | 365 |
2008 | S & S ENERGY CORP | 668.00 | 0.00 | 365 |
2009 | S & S ENERGY CORP | 343.00 | 0.00 | 365 |
2010 | S & S ENERGY CORP | 45.00 | 0.00 | 365 |
2011 | S & S ENERGY CORP | 220.00 | 0.00 | 365 |
2012 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2013 | S & S ENERGY CORP | 288.00 | 0.00 | 365 |
2014 | S & S ENERGY CORP | 291.00 | 0.00 | 365 |
2015 | D & D ENERGY COMPANY | 153.00 | 0.00 | 365 |
2016 | D & D ENERGY COMPANY | 229.00 | 0.00 | 365 |
2017 | D & D ENERGY COMPANY | 182.00 | 0.00 | 365 |
2018 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1064895420 | 2015-10-13 0:00 | PW | No Violations | 1.00 |
-40311735 | 2018-7-9 0:00:0 | PW | No Violations | 2.00 |
-442872385 | 2015-10-9 0:00: | PW | No Violations | 5.00 |
-450606902 | 2016-9-1 0:00:0 | PW | No Violations | 1.50 |
0000019688 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 6/6/91 INSPECTOR BRETT FARNSWORTH DATE 06/0619/91 DATA FROM OLD VAX INFO | |
0040311735 | 2018-07-09 | Production Wells | No Violations | On the day of my inspection I found this well equipped with a walking beam pumping unit that it not connected to the rods in the well. Purpose of this inspection is to follow up on complaint number 5419 about lease road erosion. Pumping unit has a natural gas engine. Valve on tubing is closed. Casing valve open to domestic gas line. Production equipment includes 2 poly brine tanks, a 210 barrel steel tank, and horizontal seperator. One tank is cracked from a tree falling onto it and could potentially over flow with a heavy rain. The tanks are ~150 west of the seperator. All equipment within containment. Well and production equipment is poorly labeled. No erosion noted on lease road. Production records are current. |
0442872385 | 2015-10-09 | Production Wells | Violations Noted | I had a call from the landowner of the well Mr. Bill Corcoran of 84555 Mcgill Rd Deersville, Ohio - phone # 330-388-7791 to advise me that there was an H2S leak at his home and at the well head near his home. He said that it was leaking and he was concerned about other homeowners safety. He did know the name of the well and I contacted the Operator Bob Didi of D&D Energy Service to advise I had received a call that his well was leaking gas and H2S . I contacted Inspector Akins and together we went to the well to investigate. Upon arriving at the well it was discovered there was no easy way to approach the well because of the steep terrain and thick underbrush. Our safety meters went on alarm for methane and LEL but did not register any H2S. During our inspection we found that there were several gas leaks on fittings and lines that need repaired. I advised Bob Didi about the leaks and the need to repair them along with the culvert which has signs of being washed out and bypassed by stream running through it. Bob is to send his pumper to correct the leaks on his next scheduled round Saturday. The culvert will need equipment and most likely a dump truck with topsoil. Bob is to work on that this next week and advise me when it has been repaired. |
0450606902 | 2016-09-01 | Production Wells | No Violations | On the day of my inspection following up on complaint number 5419 where a landowner is concerned about the condition of the lease road and culvert pipe on lease road, I found the lease road and culvert pipe were in adequate condition with the exception of on section where a 20 by 10 foot area of erosion was discovered. I witnessed the well was set up to be utilizing a pump-jack for means of production. The well consists of 4.5 inch diameter production casing, 2.375 inch diameter production tubing and rods, polish rod and stuffing box. At the time of my inspection the pump-jack was removed from the well and the production valves were placed in the open position. Production equipment for the well bore consisted of a horizontal separator and a 2 inch diameter meter run. A domestic gas hook-up is plumed into the separator. RBDMS records indicate that the well is in producing order. After my inspection I called the landowner and well owner; they came to an agreement that the well owner Bob Diddi would fix the erosion on the lease road. |
1064895420 | 2015-10-13 | Production Wells | No Violations | I returned today to check on the repair status of the gas leaks at the well head on several fittings and lines. I found that the leaks are fixed and my gas detector did not go on alarm today. Repairs to the culvert are to begin after the operator is able to find and mobilize equipment. Bob Didi, the owner, said he will need a dozer, backhoe and a dump truck. |
19688 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0442872385 | US-OH-124769 | 2016-05-04 | Well insufficiently equipped to prevent escape of oil and gas |
For data sources see[9]