If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-067-21362 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.22,"lon":-81.17,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Harrison | |
Municipality: Moorefield Township | |
Operator Name: ASCENT RESOURCES UTICA LLC | |
Well Pad ID: US-OH-000902 | |
Farm/Lease Name: RH HAMILTON N MRF HR | |
License Status: Producing | |
License Date: 2014-08-11 | |
Spud Date: 2014-08-18 | |
Spud Drilling Contractor: PATTERSON DRILLING | |
Final Drill Date: 2014-10-12 | |
Well Total Depth: 18019.00 ft | |
Configuration: Horizontal | |
Latitude: 40.220000 | |
Longitude: -81.170000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2014-06-20 | Proposed Formations:TRENTON, Issued Date:6/20/2014, Expired Date:6/19/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
APP | 2014-08-11 | Proposed Formations:POINT PLEASANT, Issued Date:8/11/2014, Expired Date:8/10/2016 12:00:00 PM, Drilling unit acres:739.615, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2014-10-12 | |
Change of Owner | 2015-08-19 | Operator changed from 9193, AMERICAN ENERGY UTICA LLC to 9520, ASCENT RESOURCES UTICA LLC |
Completion Report Received | 2016-05-19 | |
Construction Permit Expires | 2016-08-10 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2016-05-20 | 8325 | 17827 | 0 |
8325 | 17827 | 0 | |
8325 | 17827 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 09/13/2015 | 09/25/2015 | 8022 | 10,335,800.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hydrochloric Acid (HCl) | FTSI | Acid | Water | 7732-18-5 | 63 | 0.946849 | 948137 |
Hydrogen Chloride | 7647-01-0 | 37 | 0.556086 | 556843 | ||||
ICI-3240 | FTSI | Biocide | Water | 7732-18-5 | 55 | 0.0129992 | 13016.9 | |
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1,
3, 5-thiadiazine-2-thione. |
533-74-4 | 24 | 0.00567236 | 5680.08 | ||||
Sodium Hydroxide | 1310-73-2 | 23 | 0.00543601 | 5443.41 | ||||
HVG-1 4.0 | FTSI | Water gelling agent | Raffinates, Sorption Process | 64741-85-1 | 55 | 0.00729906 | 7308.99 | |
Guar gum | 9000-30-0 | 50 | 0.00663551 | 6644.54 | ||||
Isotridecanol, ethoxylated | 9043-30-5 | 2 | 0.00026542 | 265.78 | ||||
Quartz | 14808-60-7 | 4 | 0.000530841 | 531.56 | ||||
FE-200L | FTSI | Iron Control | Sodium formate | 141-53-7 | 0.6 | 0.00005251 | 52.59 | |
Sodium Hydroxide | 1310-73-2 | 2 | 0.000175046 | 175.28 | ||||
Trisodium Nitrilotriacetic acid | 5064-31-3 | 2 | 0.000175046 | 175.28 | ||||
Tetrasodium EDTA | 64-02-8 | 41 | 0.00358844 | 3593.32 | ||||
Ethylenediaminetriaceticacid, trisodium salt | 19019-43-3 | 0.8 | 0.00007002 | 70.11 | ||||
Iminodiacetate disodium salt | 17593-73-6 | 0.2 | 0.00001750 | 17.53 | ||||
Water | 7732-18-5 | 60 | 0.00525137 | 5258.52 | ||||
Sodium glycolate | 2836-32-0 | 1.5 | 0.000131284 | 131.46 | ||||
FRW-900 | FTSI | Friction Reducer | Sodium chloride (NaCl) | 7647-14-5 | 5 | 0.00285409 | 2857.97 | |
Oxyalkylated alcohol A | Proprietary | 5 | 0.00285409 | 2857.97 | ||||
Alkyl Alcohol | Proprietary | 10 | 0.00570818 | 5715.94 | ||||
Water | 7732-18-5 | 40 | 0.0228327 | 22863.8 | ||||
Water | 7732-18-5 | 55 | 0.031395 | 31437.7 | ||||
Hydrotreated Light Distillate | 64742-47-8 | 30 | 0.0171245 | 17147.8 | ||||
Sorbitan, mono-(9Z)-9-octadecenoate | 1338-43-8 | 5 | 0.00285409 | 2857.97 | ||||
Sodium Hydroxide | 1310-73-2 | 23 | 0.0131288 | 13146.7 | ||||
Anionic polymer | 25085-02-3 | 40 | 0.0228327 | 22863.8 | ||||
APB-1 | FTSI | Gel breaker | Ammonium Persulfate | 7727-54-0 | 100 | 0.000304586 | 305 | |
CS-250 SI | FTSI | Scale Inhibitor | Ethylene glycol | 107-21-1 | 10 | 0.00225094 | 2254 | |
Sodium chloride | 7647-14-5 | 6 | 0.00135056 | 1352.4 | ||||
Water | 7732-18-5 | 81 | 0.0182326 | 18257.4 | ||||
Sodium Polyacrylate | 9003-04-7 | 10 | 0.00225094 | 2254 | ||||
CI-150 | FTSI | Acid Corrosion Inhibitor | Organic amine resin salt | Proprietary | 30 | 0.000397978 | 398.52 | |
Ethylene Glycol | 107-21-1 | 30 | 0.000397978 | 398.52 | ||||
Alkylene Oxide Block Polymer | Proprietary | 10 | 0.000132659 | 132.84 | ||||
Water | 7732-18-5 | 5 | 0.00006633 | 66.42 | ||||
Diethylene glycol | 111-46-6 | 1 | 0.00001327 | 13.28 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.000132659 | 132.84 | ||||
Isopropanol | 67-63-0 | 30 | 0.000397978 | 398.52 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.000132659 | 132.84 | ||||
Fatty Acid Salt | Proprietary | 0.1 | 0.00000133 | 1.33 | ||||
Fatty Acid | Proprietary | 0.1 | 0.00000133 | 1.33 | ||||
Aliphatic alcohol | Proprietary | 0.1 | 0.00000133 | 1.33 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.000132659 | 132.84 | ||||
100 Mesh Sand | FTSI | proppant | Silica, Quartz | 14808-60-7 | 100 | 1.74398 | 1,746,360.0 | |
LTB-1 | FTSI | Breaker | Talc | 14807-96-6 | 0.6 | 0.00000183 | 1.83 | |
Ammonium Persulfate | 7727-54-0 | 84 | 0.000255852 | 256.2 | ||||
Cured acrylic resin | 25085-19-2 | 22 | 0.00006701 | 67.1 | ||||
Water | Operator | Carrier | Water | 7732-18-5 | 100 | 96.2283 | 96,359,200.0 | |
30/50 White | FTSI | proppant | Silica, Quartz | 14808-60-7 | 100 | 10.5426 | 10,557,000.0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2015-09-12 | H2O | 0 | 4972 Bbl | 200792 | STAGE 1/54
30 SHOTS STAGES 2-53 SEE IMAGES | |
2015-09-25 | H2O | 0 | 4385 Bbl | 200528 | STAGE 54/54
30 SHOTS |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | ASCENT RESOURCES UTICA LLC | 61356 | 13228 | 23 |
2016 | ASCENT RESOURCES UTICA LLC | 672124 | 97792 | 366 |
2017 | ASCENT RESOURCES UTICA LLC | 413785 | 42219 | 364 |
2018 | ASCENT RESOURCES UTICA LLC | 309059 | 20923 | 365 |
2019 | ASCENT RESOURCES UTICA LLC | 61754 | 3710 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | ASCENT RESOURCES UTICA LLC | Brine | 3479 | 23 |
2016 | ASCENT RESOURCES UTICA LLC | Brine | 9068 | 366 |
2017 | ASCENT RESOURCES UTICA LLC | Brine | 3762 | 364 |
2018 | ASCENT RESOURCES UTICA LLC | Brine | 2738 | 365 |
2019 | ASCENT RESOURCES UTICA LLC | Brine | 503 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1168229733 | 2020-2-4 0:00:0 | PW | No Violations | 1.00 |
-1264206094 | 2014-8-21 0:00: | CS | No Violations | 2.50 |
-1498259209 | 2014-9-17 0:00: | CS | No Violations | 3.00 |
-275714245 | 2014-9-18 0:00: | DD | No Violations | 2.50 |
-656803056 | 2016-3-1 0:00:0 | PL | No Violations | 0.50 |
0002901489 | 2016-01-05 | Production Wells | No Violations | On the day of my inspection I accompanied ODNR Inspector Joe Zollars please refer to his report for details. |
0216800795 | 2014-08-18 | Drill / Deepen / Reopen | No Violations | On the date of inspection I accompanied ODNR Inspector Mark Moreland to check the status of the conductor hole being drilled and when it would be cemented. Refer to Mark Morelands report for further details. |
0275714245 | 2014-09-18 | Drill / Deepen / Reopen | No Violations | I am on site today to meet with Drilling Superintendent Stan Cherry and Operation Manager Jim Tully. They requested the meeting to find out more details of the changes to the casing program which have been proposed by ODNR. I did advise the group that the final changes have not been made known to anyone at this time. I also advised that changes will continue for some time and if they wanted to meet with ODNR that they could do so. Later in the day I advised Deputy Chief Dave Claus and Bob Worstall of the request to meet with A.E.U. |
0656803056 | 2016-03-01 | Preliminary Restoration | No Violations | This well is in production and meets the requirements for the preliminary restoration. This well is one of 9 wells in operation on this pad and has proper identification. To see a list of the production equipment see permit # 1366 |
1187467181 | 2016-01-05 | Preliminary Restoration | No Violations | On the day of my inspection accompanied by Inspector Doug Bennett, I witness the well head is equipped with a production tree with valves in the open position. The production equipment included a sand trap and a GP unit. Also present were 3 stabilizer units, 2 line heaters, 2 compressor units, 3 NGL tanks, 2 combustors, 8- 500bbl condensate tanks and 4-500bbl brine tanks all within proper containment. This equipment is shared with the 5H, 3H, 1H, 2H, 4H, 6H, 8H and 10H. The site passed preliminary restoration in accordance with ORC 1509.072 A. |
1254475309 | 2018-12-13 | Production Wells | No Violations | On the day of my inspection I was accompanied by Deputy Chief Bob Worstall and Inspector John Fleming. This pad contains nine properly labeled producing wellheads utilizing a plunger lift system. Production equipment includes eight 500 barrel steel tanks in their own polymer lined steel containment, nine GPUs, nine sand seperators, three horizontal dehydrators, a compressor, and a vapor recovery unit. Surface annular pressure is 0 and intermediate annular pressure is 0. Production records are current in RBDMS. |
1264206094 | 2014-08-21 | Casing String Witnessed | No Violations | I am on site tonight to witness the running and the cementing of the 26 inch diameter casing string. Precision Drilling drilled a 30 inch diameter hole to 100 ft. and set 100 ft. of casing. O-Tex Cementing Service cemented with 190 sacks of class H cement at 15.6 and a yield of 1.20 had only 3 bbls of return. |
1408680509 | 2014-08-21 | Casing String Witnessed | No Violations | I am on site tonight to witness the running and the cementing of the 26 inch diameter casing string. Precision Rat hole Service drilled a 30 inch diameter hole to 100 ft. and set 100 ft. of casing. O-Tex Cementing Service cemented casing with 190 sacks of class H cement at 15.6 lb. and a yield of 1.20 and had 3 bbls of cement returns. |
1410351382 | 2014-09-06 | Casing String Witnessed | No Violations | The rig ran 20 casing and the asociated float equipment to 553. O-Tex cementing cemented the casing with 580 sacks of class A cement. See the casing ticket for the details. |
1410367757 | 2014-09-10 | Casing String Witnessed | No Violations | On the day of my inspection I found that AEU was not ready to cement casing. Patterson Drilling rig 256 had drilled a 17.5 hole to a depth of 1990. They were running new, centralized 13.375 casing. They were having problems getting the last two joint of casing in the hole. They were trying to wash the joints in. |
1410867289 | 2014-09-15 | Drill / Deepen / Reopen | No Violations | I am on site today to check on the drilling status of Patterson Drilling Rig # 256 and found that they are at 6700 ft. on vertical section of the well. They will set a deep intermediate casing which they plan not to run a DV Tool. That means if the formation integrity does not support the weight of the cement they will not be able to circulate cement to the upper casing string to tie them together. |
1411388885 | 2014-09-22 | Drill / Deepen / Reopen | No Violations | Patterson Drilling Rig # 256 drilled to 8082 ft. and was off the proposed drilling track. They plugged back to correct the drill track. Today during my inspection I found that they are waiting on cement for 24 hours and will begin drilling at 6025 ft. to begin rebuilding the curve. |
1412096434 | 2014-09-30 | Drill / Deepen / Reopen | No Violations | I am on site today to check on the Patterson Drilling Rig # 256 and found them drilling at 10,976 ft. drilling a 8.5 inch diameter hole with oil base drilling mud. Move to the # 5 -H well after this is complete. |
1498259209 | 2014-09-17 | Casing String Witnessed | No Violations | Patterson Drilling Rig # 256 drilled a 12-1/4 inch diameter hole to 7110 ft. and set 7100 ft. of 9-5/8 inch diameter 40 lb casing. O-Tex Cementing Service cemented with 1090 sacks of lead cement at 12 lb and yield of 2.15 and a tail cement of 220 sacks at 15.3 and a yield of 1.27 did not get cement returns and advised Cecil the Company Man for AEU to complete a bond log before drilling out from under cement to determine the top of the cement. This job was not a 2 stage cement job and they did not run a DV Tool. |
216800795 | 2014-8-18 0:00: | DD | No Violations | 0.50 |
2901489 | 2016-1-5 0:00:0 | PW | No Violations | 0.50 |
For data sources see[10]