If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-073-20257 | ![]() Sorry, we have no imagery here. Sorry, we have no imagery here. ![]() |
Country: United States | |
State: Ohio | |
County: Hocking | |
Municipality: Washington Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: WATTS ELI | |
License Status: Storage Well | |
License Date: | |
Spud Date: 1950-07-03 | |
Spud Drilling Contractor: | |
Final Drill Date: 1950-10-10 | |
Well Total Depth: 2540.00 ft | |
Configuration: Vertical | |
Latitude: 39.420000 | |
Longitude: -82.510000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1950-07-03 | GL=870.4, STORAGE |
Completed | 1950-10-10 | GL=870.4, STORAGE |
Reached Total Depth | 1950-10-10 | GL=870.4, STORAGE |
Change of Owner | 2011-08-17 | Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION |
Record Last Modified | 2013-03-11 | GL=870.4, STORAGE |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1796876436 | 2018-7-26 0:00: | SO | No Violations | 0.10 |
-230974460 | 2017-6-14 0:00: | SO | No Violations | 0.90 |
-489851789 | 2014-1-27 0:00: | SO | No Violations | 0.50 |
-671426211 | 2019-11-6 0:00: | SO | No Violations | |
-676512191 | 2015-9-28 0:00: | SO | No Violations | 0.70 |
-80465377 | 2016-7-11 0:00: | SO | No Violations | 1.00 |
-929176397 | 2013-10-22 0:00 | SO | No Violations | 1.00 |
0080465377 | 2016-07-11 | Storage Well | No Violations | Storage well inspection. The well has a legible identification. No violations noted. |
0230974460 | 2017-06-14 | Storage Well | No Violations | Columbia Gas storage well inspection. The well consists of a wellhead and a drip. Legible identification on wellhead, no violations noted, GPS was taken on day of inspection. |
0231367200 | 2012-01-27 | Storage Well | No Violations | No violations at the time of inspection. |
0489851789 | 2014-01-27 | Storage Well | Violations Noted | CGT is using Watts as their lease name on the wells identification sign which is incorrect according to Columbus records. I will contact Jason Martin of CGT about the correction. RBDMS needs to add CGTs unique well number to the well number and/or lease name. Access road is off Ilesboro County Road (#272). |
0666356307 | 2014-01-27 | Storage Well | No Violations | FOLLOW UP TO NOV # -489851789 CGT is using Watts as their lease name on the wells identification sign which is incorrect according to Columbus records. I will contact Jason Martin of CGT about the correction. RBDMS needs to add CGTs unique well number to the well number and/or lease name. Access road is off Ilesboro County Road (#272). |
0676512191 | 2015-09-28 | Storage Well | No Violations | Storage well inspection. Legible well identification found at well. No violations found on date of inspection. |
0929176397 | 2013-10-22 | Storage Well | No Violations | This is a storage well. There are no leaks at the well site. The identification for this well is located at the well. No violations at this time. No production tanks for well. |
0949171406 | 2016-03-09 | Storage Well | No Violations | My inspection today is a status check on a natural gas storage well. During the time of my inspection there were not any violations and the proper identification was posted on the vertical drip. |
1281565331 | 2017-06-21 | Storage Well | No Violations | Columbia Gas storage well inspection. The well consists of a wellhead and a drip. Legible identification on wellhead, no violations noted, GPS was taken on day of inspection. |
1608702809 | 2014-04-30 | Storage Well | No Violations | Upon inspection, it was observed that the identification information posted at this well is legible and correct. This well is now in compliance. |
1796876436 | 2018-07-26 | Storage Well | No Violations | I accompanied Columbia Gas storage well technician Mr. Adam Angle to check the annulus pressure and the casing pressure. The annulus pressure was 0 psi and the casing pressure was 738 psi. |
231367200 | 2012-1-27 0:00: | SO | No Violations | 0.50 |
599330220 | 2020-3-31 0:00: | SO | No Violations | 0.30 |
666356307 | 2014-1-27 0:00: | SO | No Violations | 0.50 |
949171406 | 2016-3-9 0:00:0 | SO | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0489851789 | US-OH-125367 | 2014-03-03 | Failure to legibly identify well |
For data sources see[3]