X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-073-21207

Well Details

Well ID: 34-073-21207
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Green Township
Operator Name: HOCKING HILLS ENERGY AND WELL
Well Pad ID:
Farm/Lease Name: HUTCHINS G L & J F
License Status: Producing
License Date: 1966-03-17
Spud Date: 1966-04-12
Spud Drilling Contractor:
Final Drill Date: 1966-05-18
Well Total Depth: 2867.00 ft
Configuration: Vertical
Latitude: 39.520000
Longitude: -82.350000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1801-01-02 566 GRIM PAUL A
Original Spud 1966-04-12 GL=790.4
Completed 1966-05-18 GL=790.4
Reached Total Depth 1966-05-18 GL=790.4
Change of Owner 2001-10-29 Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP.
Record Last Modified 2013-10-03 GL=790.4

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2625 Bbl 45000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 GRIM PAUL A 546.00 76.00 365
1986 GRIM PAUL A 485.00 67.00 365
1987 GRIM PAUL A 326.00 70.00 365
1988 GRIM PAUL A 10.00 0.00 365
1989 GRIM PAUL A 0.00 0.00 365
1990 GRIM PAUL A 0.00 0.00 365
1991 GRIM PAUL A 0.00 44.00 365
1992 GRIM PAUL A 0.00 28.00 365
1993 GRIM PAUL A 0.00 36.00 180
1994 GRIM PAUL A 0.00 0.00 365
1995 GRIM PAUL A 0.00 33.00 365
1996 GRIM PAUL A 0.00 3.00 365
1997 GRIM PAUL A 0.00 0.00 365
1998 GRIM PAUL A 0.00 0.00 365
1999 GRIM PAUL A 0.00 0.00 365
2000 GRIM PAUL A 0.00 0.00 365
2001 GRIM PAUL A 0.00 0.00 365
2002 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2003 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2004 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365
2005 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365
2006 HOCKING HILLS ENERGY AND WELL 11.00 0.00 365
2007 HOCKING HILLS ENERGY AND WELL 156.00 0.00 365
2008 HOCKING HILLS ENERGY AND WELL 156.00 0.00 365
2009 HOCKING HILLS ENERGY AND WELL 156.00 0.00 365
2010 HOCKING HILLS ENERGY AND WELL 392.00 46.00 365
2011 HOCKING HILLS ENERGY AND WELL 53.00 0.00 365
2012 HOCKING HILLS ENERGY AND WELL 557.00 42.00 366
2013 HOCKING HILLS ENERGY AND WELL 278.00 17.00 365
2014 HOCKING HILLS ENERGY AND WELL 75.00 18.00 365
2015 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365
2016 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365
2017 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 GRIM PAUL A Brine 293 365
1986 GRIM PAUL A Brine 430 365
1987 GRIM PAUL A Brine 123 365
1988 GRIM PAUL A Brine 0 365
1989 GRIM PAUL A Brine 0 365
1990 GRIM PAUL A Brine 0 365
1991 GRIM PAUL A Brine 0 365
1992 GRIM PAUL A Brine 0 365
1993 GRIM PAUL A Brine 15 180
1994 GRIM PAUL A Brine 20 365
1995 GRIM PAUL A Brine 50 365
1996 GRIM PAUL A Brine 10 365
1997 GRIM PAUL A Brine 0 365
1998 GRIM PAUL A Brine 0 365
1999 GRIM PAUL A Brine 0 365
2000 GRIM PAUL A Brine 0 365
2001 GRIM PAUL A Brine 0 365
2002 HOCKING HILLS ENERGY AND WELL Brine 0 0
2003 HOCKING HILLS ENERGY AND WELL Brine 0 0
2004 HOCKING HILLS ENERGY AND WELL Brine 55 365
2005 HOCKING HILLS ENERGY AND WELL Brine 90 365
2006 HOCKING HILLS ENERGY AND WELL Brine 120 365
2007 HOCKING HILLS ENERGY AND WELL Brine 0 365
2008 HOCKING HILLS ENERGY AND WELL Brine 0 365
2009 HOCKING HILLS ENERGY AND WELL Brine 0 365
2010 HOCKING HILLS ENERGY AND WELL Brine 60 365
2011 HOCKING HILLS ENERGY AND WELL Brine 55 365
2012 HOCKING HILLS ENERGY AND WELL Brine 480 366
2013 HOCKING HILLS ENERGY AND WELL Brine 490 365
2014 HOCKING HILLS ENERGY AND WELL Brine 315 365
2015 HOCKING HILLS ENERGY AND WELL Brine 0 365
2016 HOCKING HILLS ENERGY AND WELL Brine 0 365
2017 HOCKING HILLS ENERGY AND WELL Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1055693658 2009-5-1 0:00:0 PW No Violations
-1144223769 2020-8-26 0:00: PW No Violations 4.00
-1337485421 2010-8-3 0:00:0 PW No Violations
-206177255 2006-7-19 0:00: PW No Violations
-488691266 2009-3-18 0:00: PW No Violations
-759412291 2006-12-4 0:00: PW No Violations
0145263011 2019-01-09 Production Wells No Violations I conducted an inspection on this well today accompanied by landowner Barney Cook. My inspection revealed that the well was equipped with a pumping unit but no motor. The well was not capable of production. This well produces into a shared tank battery with API permit number 1157. The tank battery consists of (2) 100 barrel tanks and a knockout tank inside an earthen dike. Identification was posted at the tank battery but not at the well. The last year for reported commercial production was 2014 in which Hocking Hills Energy and Well Service reported 18 barrels of oil and 75 mcf of gas. I took four photos of the well. The well owner/operator shall submit a written plugging schedule to Brandon Mitchell at 5880 Memory Road Zanesville, Ohio 43701-9553 within 30 days, per ORC 1509:13(B)(7), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied. Time of inspection: 9:05 AM. Weather: 28 degrees F, Snowing
0206177255 2006-07-19 Production Wells No Violations Idle well, no ID, Brent Bear will issue NOV.
0370771638 2009-10-13 Production Wells No Violations A follow-up inspection to Notice of Violation and Compliance Agreement Schedule composed on 7/14/2009 with a deadline of 12/15/2009 for production revealed non-compliance. Prior to agreement, the NOV deadline was 5/7/2009. An inspection of progress remains unchanged. The well is equipped, but bridle not connected. The 1 gas line still remains in several sections to include location away from well near pond on top of hill. The second location is near the well behind 100 bbl tank (not a common tank battery) at edge of wooded area. 1 line cut before connecting into 1 line routed through 2 steel.
0488691266 2009-03-18 Production Wells No Violations FOLLOW UP TO NOV # 1296495853 FOLLOW UP TO NOV # 1967679252 A complaint was received alleging non-production and flowline burial. An inspection revealed that the well is idle. The well contains a pump jack, but the bridle was found to be disconnected. The flowline from this well was found connected to a nearby
0600307856 2014-03-20 Production Wells No Violations Compliance notice follow-up. The well is in compliance, this satisfies the compliance notice.
0622065734 2014-11-19 Production Wells No Violations Production well inspection, the well consists of a tank battery and a pumping unit. The well was in operation during my inspection. No violations noted.
0759412291 2006-12-04 Production Wells No Violations A follow-up inspection conducted on 12/4/2006 revealed that the previously noted violations have been resolved.
0816982664 2012-02-27 Production Wells Violations Noted The dike surrounding the well head was full of fluid at the time of inspection. When tested with a High Range Quantab titrator for chlorides, there were no chlorides detected. Identification tag was covered with oil and grease to the point that it was not legible. Met Mr. Ron McBride, and discussed issues with him. He agreed to comply.
0875664994 2010-01-04 Administrative Inspection No Violations Spoke with Mr. Paul Grims service rig crew at their shop today. They state that their service rig has been placed on this well.
0984912404 2010-01-06 Production Wells No Violations A follow-up inspection revealed that Paul Grims service rig has been placed on the well. It was noted that the rods have been pulled and the pump has been taken to Ohio Pump & Supply for repair. Mr. Grims crew are preparing to pull tubing. Note: winter conds to include snow cover at time of inspection.
1019513820 2010-03-24 Production Wells No Violations A follow-up inspection revealed non-compliance. An earthen dike has been built around the well head, and P&C cleaned up at the well. No observed identification and venting gas.
1047697031 2019-7-11 0:00: PW No Violations 0.20
1055693658 2009-05-01 Production Wells No Violations A follow-up inspection revealed non-compliance.
1076793290 2010-03-01 Production Wells Violations Noted A follow-up inspection revealed that the well has been placed back into production. The well is equipped with a pumping unit and contains production equipment at the well head. The well is tied into a nearby 100 bbl tank. At the well location, a 12 x 12 area contained fresh oil from a stuffing box leak. The well was also observed to be venting gas. Notifed Mr. Doug Kitchen today at 8:40 am at the location. Mr. Kitchen was instructed to remove P&C and to not vent gas. Mr. Kitchen plans to eventually sell gas from this well. He states that they knew about the P&C because, the stuffing box rubbers were bad. Note: snow cover at time of inspection. Remove all contaminated material from the well location. The well shall be equipped to prevent the escape of oil. Replace the stuffing box rubbers. Do not vent gas without the use of a flare.
1154299273 2006-07-19 Production Wells Violations Noted An inspection was conducted at the facility owned by Chieftain Energy Corp on 7/19/2006. During the inspection, it was noted that the pump jack was missing a cylinder head and proper identification. It was also noted that gas was leaking from the wellhead and the well appeared to be idle. The polishing rod was rusted, valves were closed and the gas hose feeding to the engine was not hooked up. The area surrounding the tank battery showed signs of a spill, whch may have affected a nearby creek. At the time of the inspection, oil was not observed upstream nor downstream of the spill. It was noted however, that a dike has been built. The ID located at the tank battery must be corrected and show the correct area code and permit number.
1162995734 2006-11-07 Production Wells No Violations A follow-up inspection revealed that the company is working towards resolving the NOV. It was noted that the tank battery has been moved and is now greater than 50 from the road. Also a new dike has been built for the tanks. Additional work is still needed such as, a new ID, and well is still idle.
1264613726 2010-01-26 Production Wells No Violations A follow-up inspection revealed that rods and tubing have been placed back into well bore. The service rig remains on site. The line from the well to 100 bbl located nearby will need to be connected. ID not present.
1296495853 2009-03-18 Production Wells No Violations FOLLOW UP TO NOV # 1967679252 A complaint was received alleging non-production and flowline burial. An inspection revealed that the well is idle. The well contains a pump jack, but the bridle was found to be disconnected. The flowline from this well was found connected to a nearby
1331832331 2012-03-15 Production Wells No Violations There were no violations noted during inspection. Well is in compliance. Flow line was being buried at the time of inspection.
1337485421 2010-08-03 Production Wells No Violations A follow-up inspection revealed new identification at the well. The 100 bbl tank has now been moved to the front of the property. (Note: shared battery). No submittal of production reports. Remedial Restoration recommended around well site. On 8/17/2010, at 5:48 p.m., a Remedial Restoration of the well site was recommended to Mr. Doug Kitchen, due to the lack of vegetation and observed erosion from equipment ( service rig and removal of 100 bbl tank). Mr. Kitchen agreed to perform the work and also states that 3 bbl oil now exists at well head and will need cleaned up.
145263011 2019-1-9 0:00:0 PW No Violations 0.40
1967679252 2009-03-18 Production Wells Violations Noted A complaint was received alleging non-production and flowline burial. An inspection revealed that the well is idle. The well contains a pump jack, but the bridle was found to be disconnected. The flowline from this well was found connected to a nearby 100 bbl tank with no knockout tank. The tank appeared to be empty. Plastic flowline from the casing side of the well was observed cut in two locations. The first location (near the tank) is parted next to a steel line, which may have been tied together at one time and routed through the woods. The second location was found on top of hill near a separator. Chieftain Energy obtained ownership of this well in 2001 from Mr. Paul Grim. From 2002 to 2005, RBDMS records indicate that there was no oil or gas production. Prior to 2002, the last year for production was 3 bbls of oil in 1996. In 2006, Chieftain Energy reported gas production (same figure for permit #1157). Currently, no statement of production of oil, gas and brine has been submitted for 2007 and 2008 (ORC 1509.11). Permit #1157 is routed to (2) 100 bbl tanks near the road. A meter located near the tank battery contained a chart (no sign of production, which stated February 2009. A valve was observed closed on the gas line routed to a separator at this location. The landowner states that this well has not been pumped in a few years. Identification was not observed and will need to be provided. The majority of the flowline from this well is routed through a wooded area and placed along a hillside. Therefore, the burial of flowline will not be required at these locations. Plug or produce this well. The bridle is disconnected and the flowline will need to be repaired. Please provide identification. Your attention is also directed to ORC 1509.11. Our records do not show a statement of production of oil, gas and brine fo
2038515458 2009-12-10 Administrative Inspection No Violations A follow-up administrative inspection, in the field, was conducted with Mr. Robert Stonerock, South Region Oil & Gas Supervisor. Reviewed and discussed non-production from this well.
370771638 2009-10-13 0:00 PW No Violations
600307856 2014-3-20 0:00: PW No Violations 1.00
622065734 2014-11-19 0:00 PW No Violations 2.00
816982664 2012-2-27 0:00: PW No Violations 2.50
875664994 2010-1-4 0:00:0 AM No Violations
984912404 2010-1-6 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0816982664 US-OH-129301 2012-02-28 Failure to legibly identify well
0816982664 US-OH-129302 2012-02-28 No SPCC dike/or failure to keep dike free of water or oil
1076793290 US-OH-101654 2010-03-05 Well operation causing pollution and contamination
1076793290 US-OH-101655 2010-03-05 Well insufficiently equipped to prevent escape of oil and gas
1076793290 US-OH-101656 2010-03-05 Failure to legibly identify well
1076793290 US-OH-101657 2010-03-05 Unlawful venting or flaring of gas
1154299273 US-OH-104019 2006-08-10 Well insufficiently equipped to prevent escape of oil and gas
1154299273 US-OH-104020 2006-08-03 Failure to legibly identify well
1154299273 US-OH-104021 2006-08-10 Improperly located oil tank
1154299273 US-OH-104022 2006-08-10 No SPCC dike/or failure to keep dike free of water or oil
1154299273 US-OH-104023 2006-08-10 Well shall be plugged
1967679252 US-OH-119877 2009-04-06 Inadequate pipeline strength
1967679252 US-OH-119878 2009-04-06 Failure to legibly identify well
1967679252 US-OH-119879 2009-04-06 Well shall be plugged

For data sources see[8]