34-073-21889

Well Details

Well ID: 34-073-21889
Loading map...
Country: United States
State: Ohio
County: Athens
Municipality: York Township
Operator Name: NUTTCO OIL & GAS
Well Pad ID:
Farm/Lease Name: NATCO
License Status: Final Restoration
License Date: 2010-11-16
Spud Date: 1976-06-01
Spud Drilling Contractor:
Final Drill Date: 1976-06-30
Well Total Depth: 3217.00 ft
Configuration: Vertical
Latitude: 39.470000
Longitude: -82.280000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1976-04-13 133 QUAKER STATE OIL REF CORP GeoDate 4/13/76
Original Spud 1976-06-01
Completed 1976-06-30
Reached Total Depth 1976-06-30
CO 1995-05-05 4074 OIL ENTERPRISES GeoDate 4/13/76
Change of Owner 2001-03-22 Operator changed from 4074, OIL ENTERPRISES to 4243, NUTTCO OIL & GAS
APP 2010-11-16 Proposed Formations:CLINTON, Issued Date:11/16/2010, Expired Date:11/15/2012 12:00:00 PM, Drilling unit acres:160, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2010-11-24
Construction Permit Expires 2012-11-15
Record Last Modified 2013-03-14

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2000 Bbl 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 QUAKER STATE OIL REF CORP 805.00 426.00 0
1985 QUAKER STATE OIL REF CORP 639.00 367.00 365
1986 QUAKER STATE OIL REF CORP 485.00 342.00 365
1987 QUAKER STATE OIL REF CORP 473.00 579.00 365
1988 QUAKER STATE OIL REF CORP 1049.00 678.00 365
1989 QUAKER STATE OIL REF CORP 1632.00 722.00 365
1990 QUAKER STATE OIL REF CORP 998.00 386.00 365
1991 QUAKER STATE OIL REF CORP 832.00 262.00 365
1992 QUAKER STATE OIL REF CORP 439.00 195.00 365
1993 QUAKER STATE OIL REF CORP 274.00 174.00 365
1994 QUAKER STATE OIL REF CORP 157.00 152.00 365
1995 OIL ENTERPRISES 140.00 115.00 240
1996 OIL ENTERPRISES 160.00 215.00 365
1997 OIL ENTERPRISES 191.00 202.00 365
1998 OIL ENTERPRISES 188.00 168.00 365
1999 OIL ENTERPRISES 128.00 126.00 365
2000 OIL ENTERPRISES 81.00 67.00 365
2002 NUTTCO OIL & GAS 0.00 80.00 100
2003 NUTTCO OIL & GAS 0.00 160.00 104
2004 NUTTCO OIL & GAS 0.00 64.00 150
2005 NUTTCO OIL & GAS 20.00 240.00 220
2006 NUTTCO OIL & GAS 0.00 240.00 250

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 QUAKER STATE OIL REF CORP Brine 0 0
1985 QUAKER STATE OIL REF CORP Brine 107 365
1986 QUAKER STATE OIL REF CORP Brine 95 365
1987 QUAKER STATE OIL REF CORP Brine 50 365
1988 QUAKER STATE OIL REF CORP Brine 42 365
1989 QUAKER STATE OIL REF CORP Brine 46 365
1990 QUAKER STATE OIL REF CORP Brine 67 365
1991 QUAKER STATE OIL REF CORP Brine 39 365
1992 QUAKER STATE OIL REF CORP Brine 31 365
1993 QUAKER STATE OIL REF CORP Brine 45 365
1994 QUAKER STATE OIL REF CORP Brine 33 365
1995 OIL ENTERPRISES Brine 0 240
1996 OIL ENTERPRISES Brine 0 365
1997 OIL ENTERPRISES Brine 106 365
1998 OIL ENTERPRISES Brine 100 365
1999 OIL ENTERPRISES Brine 100 365
2000 OIL ENTERPRISES Brine 100 365
2002 NUTTCO OIL & GAS Brine 0 100
2003 NUTTCO OIL & GAS Brine 0 104
2004 NUTTCO OIL & GAS Brine 20 150
2005 NUTTCO OIL & GAS Brine 10 220
2006 NUTTCO OIL & GAS Brine 0 250

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1160145402 2010-11-19 0:00 PB No Violations 3.00
-671752748 2011-10-17 0:00 FR No Violations 1.00
-715195599 2010-11-24 0:00 PB No Violations 5.50
0671752748 2011-10-17 Final Restoration No Violations Well was located where new highway is being built. Well is covered by a sandstone blanket as per ODOT specification, then covered with 50 feet of fill. Accompanied by Jeff Amos from ODOT.
0715195599 2010-11-24 Plug / Plug Back No Violations Witnessed plugging and abandonment. The plugging contractor, Berry Well Service, states that 7 does not exist in well bore. Records are not accurate as only 8 casing exists. Discussed scenario with MRI 3 and left 8 casing in the well bore to protect freshwater. The cement stayed at the surface. Advised Mr. Tony Kilbarger to leave well bore open for a couple days to monitor cement top. The Ohio Department of Transportation requests installation of Vent & Vault system, due to well being situated in a Right-of-Way for the construction of Nelsonville Bypass. A follow-up inspection will be performed to check status of cement top and leaks.
1160145402 2010-11-19 Plug / Plug Back No Violations Witnessed bottom plug through tubing. Prior to setting this plug, a Parmaco packer on 2.875 tubing ran to approx 1200 was retrieved from well bore. Records did not show this information was ever placed in well bore.
1685896149 2010-11-22 Plug / Plug Back No Violations Witnessed both Big Lime and Berea plugs. Records at this time indicate that 7 casing was never pre-pulled and 8 also exists in hole (mudded-in). Advised company to set plug approx 50 below alleged 7 and to 100 above Berea to ensure cover, if problem were to occur downhole. Note: 4.5 casing ripped at 2197.
1999992020 2010-11-29 Plug / Plug Back No Violations A follow-up inspection was conducted to verify status of cement top in well bore and leakage. No observed leakage or detection with gas meter. It was noted that the cement has dropped since last Wednesday and no longer observed at surface. Fluid in and around outside of wellbore. Placed a stick approximately 5 long inside wellbore and did not encounter material. Mr. Tony Kilbarger would later state this evening that he measured cement between 19-20. Mr. Kilbarger agreed to place approved fireclay in wellbore. Note: cable tool drilled well. Although the well is not leaking, Mr. Cary Betzing with ODOT, 740-753-0261, had requested the installation of Vent & Vault system for the well prior to plugging and abandonment. Mr. Betzing states that the well will be situated in a Right-of-Way for Nelsonville Bypass and difficult to access, if said well were to ever leak. ODOT design for installation calls for casing cut 5 below grade. Therefore, approximately 15 of clay would be placed in wellbore.

For data sources see[8]

References