Well Details

Well ID: 34-073-22002
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Green Township
Operator Name: HOCKING HILLS ENERGY AND WELL
Well Pad ID:
Farm/Lease Name: GOSS JOHN & DIANE ; BAILEY HARVEY
License Status: Producing
License Date: 1977-09-02
Spud Date: 1977-09-01
Spud Drilling Contractor:
Final Drill Date: 1977-10-10
Well Total Depth: 2836.00 ft
Configuration: Vertical
Latitude: 39.540000
Longitude: -82.350000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1977-09-01
CO 1977-09-02 566 GRIM PAUL A GeoDate 9/2/77
Completed 1977-10-10
Reached Total Depth 1977-10-10
Change of Owner 2001-10-29 Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP.
Record Last Modified 2013-10-03

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 7000 Bbl 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GRIM PAUL A 662.00 90.00 365
1985 GRIM PAUL A 212.00 198.00 365
1986 GRIM PAUL A 0.00 16.00 365
1987 GRIM PAUL A 0.00 93.00 365
1988 GRIM PAUL A 0.00 133.00 365
1989 GRIM PAUL A 0.00 73.00 365
1990 GRIM PAUL A 0.00 114.00 365
1991 GRIM PAUL A 0.00 38.00 365
1992 GRIM PAUL A 0.00 43.00 365
1993 GRIM PAUL A 0.00 0.00 365
1994 GRIM PAUL A 0.00 0.00 365
1995 GRIM PAUL A 0.00 0.00 365
1996 GRIM PAUL A 0.00 0.00 365
1997 GRIM PAUL A 0.00 0.00 365
1998 GRIM PAUL A 0.00 0.00 365
1999 GRIM PAUL A 0.00 0.00 365
2000 GRIM PAUL A 0.00 0.00 365
2001 GRIM PAUL A 0.00 0.00 365
2002 HOCKING HILLS ENERGY AND WELL 0.00 0.00 10
2003 HOCKING HILLS ENERGY AND WELL 0.00 9.00 10
2004 HOCKING HILLS ENERGY AND WELL 0.00 52.00 365
2005 HOCKING HILLS ENERGY AND WELL 0.00 32.00 365
2006 HOCKING HILLS ENERGY AND WELL 0.00 63.00 365
2007 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365
2008 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365
2009 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365
2010 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2011 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2012 HOCKING HILLS ENERGY AND WELL 0.00 0.00 100
2013 HOCKING HILLS ENERGY AND WELL 0.00 40.00 100
2014 HOCKING HILLS ENERGY AND WELL 0.00 102.00 100
2015 HOCKING HILLS ENERGY AND WELL 0.00 45.00 100
2016 HOCKING HILLS ENERGY AND WELL 0.00 37.00 100
2017 HOCKING HILLS ENERGY AND WELL 0.00 14.00 100

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GRIM PAUL A Brine 0 365
1985 GRIM PAUL A Brine 9 365
1986 GRIM PAUL A Brine 0 365
1987 GRIM PAUL A Brine 0 365
1988 GRIM PAUL A Brine 0 365
1989 GRIM PAUL A Brine 0 365
1990 GRIM PAUL A Brine 120 365
1991 GRIM PAUL A Brine 0 365
1992 GRIM PAUL A Brine 0 365
1993 GRIM PAUL A Brine 0 365
1994 GRIM PAUL A Brine 0 365
1995 GRIM PAUL A Brine 0 365
1996 GRIM PAUL A Brine 0 365
1997 GRIM PAUL A Brine 0 365
1998 GRIM PAUL A Brine 0 365
1999 GRIM PAUL A Brine 0 365
2000 GRIM PAUL A Brine 0 365
2001 GRIM PAUL A Brine 0 365
2002 HOCKING HILLS ENERGY AND WELL Brine 0 10
2003 HOCKING HILLS ENERGY AND WELL Brine 0 10
2004 HOCKING HILLS ENERGY AND WELL Brine 25 365
2005 HOCKING HILLS ENERGY AND WELL Brine 130 365
2006 HOCKING HILLS ENERGY AND WELL Brine 100 365
2007 HOCKING HILLS ENERGY AND WELL Brine 0 365
2008 HOCKING HILLS ENERGY AND WELL Brine 0 365
2009 HOCKING HILLS ENERGY AND WELL Brine 0 365
2010 HOCKING HILLS ENERGY AND WELL Brine 0 0
2011 HOCKING HILLS ENERGY AND WELL Brine 55
2012 HOCKING HILLS ENERGY AND WELL Brine 60 100
2013 HOCKING HILLS ENERGY AND WELL Brine 700 100
2014 HOCKING HILLS ENERGY AND WELL Brine 420 100
2015 HOCKING HILLS ENERGY AND WELL Brine 200 100
2016 HOCKING HILLS ENERGY AND WELL Brine 0 100
2017 HOCKING HILLS ENERGY AND WELL Brine 0 100

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1563677384 2009-5-27 0:00: PW No Violations
-285240430 2009-9-22 0:00: PW No Violations
-414227181 2011-8-2 0:00:0 PW No Violations
-861029983 2011-8-4 0:00:0 PW No Violations 4.00
0285240430 2009-09-22 Production Wells No Violations A follow-up inspection revealed that company has been making attempt to pump the well. The flywheel appears to have broke, as it has been removed and will need repaired. At time of the inspection, no leaks observed from 210 bbl tank. Chieftain Energy contractor states that they placed bentonite inside tank to remedy the leak. A 1 plastic line from well is routed to residential dwelling for house gas.
0414227181 2011-08-02 Production Wells Violations Noted Tank battery was full of oil and brine. It had overflown the dike and a plume of vegetation kill was observed 20x25 yards in area. 210 barrel tank seemed to be empty. As noted from a previous inspection, the plastic tank that was in the battery was cracked and had large holes in it. A high range quantab test was ran on the fluid in the dike. It showed 2.6 which is representative of 376 parts per million (milligrams per liter). 250 parts per million (milligrams per liter) is the EPA acceptable value. Further research on the well in RBDMS shows that the well has not been in commercial production since 2007. Doug Kitchen was called immediately after inspection and a voicemail was left on his phone. Ron McBride was also called and notified of the situation. Well needs to be produced, plugged or placed in temporary inactive status. Property owner does receive house gas.
0497749856 2009-09-09 Administrative Inspection No Violations Mr. Ron McBride called today at 10:25 am and stated that Chieftain Energy has been pumping this well since last week.
0861029983 2011-08-04 Production Wells No Violations Witnessed clean-up efforts performed by Ron McBride. Contaminated material was hauled away by Scott Courter. Material was hauled to Chieftain Energys shop. Did chloride test for the soil in the field. It passed. Fluid was sucked out of battery. Tanks were removed from battery. Contaminated material was removed from dike area, and surrounding vegetation kill area, then filled in with good dirt. Areas will be seeded and strawed.
1034766987 2008-12-31 Production Wells No Violations A complaint was received alleging non-production. The complainant states that the company has not pumped the well for a few years. An inspection revealed that the well contains a pump jack and shows signs of pumping (ie polish rod). The complainant states that recently he has pumped the well himself. Valves were observed open with attached flowline. The company will be contacted regarding the well status.
1240587779 2009-04-01 Production Wells Violations Noted A complaint had been received alleging non-production and that house gas has not been received for 2 years. Further stating that the company had pumped the well for 3 months and then walked away. Spoke with Chieftain Energy contractor following the previous inspection, in regards to complaint and inspection results. Mr. McBride confirmed non-production and that the well had not been pumping for a few years. He was instructed to have this well placed back into production or plugged. Also mentioned was that the dike walls would need to be built up. A follow-up inspection revealed that the well is still idle. The well contains a pumping unit with 2 plastic flowline routed from the well to a 210 bbl tank. A section of the dike around the tank was found cut along the side. The well head does not contain a dike.
1304518233 2011-05-02 Production Wells Violations Noted No production since 2007. Production not submitted for 2010. A field inspection revealed that the well is equipped for production, there is no identification at the tank battery or well head. The poly tank in the tank battery was cracked all the way around and had holes in it. There was standing water with residual oil on top of it in the dike area. Horse manure was also present from a clean-up effort. The polish rod had vines growing on it. Gas was being vented from the well head. Identification needs to be placed at the well. All fluids need to be removed from dike area. Venting of gas needs to cease or gas needs to be flared. Production needs to be submitted to Columbus for 2010. If the well is not producing or capable of producing, well must be plugged or placed in temporary inactive status. Failure to do so will result in forfeiture of bond. Spoke with Doug Kitchen at 5:03 PM on 5/3/2011 regarding the venting of gas and production status of the well.
1456811063 2011-05-02 Production Wells No Violations FOLLOW UP TO NOV # 1304518233 No production since 2007. Production not submitted for 2010. A field inspection revealed that the well is equipped for production, there is no identification at the tank battery or well head. The poly tank in the tank battery was cracked all the way around and had holes in it. There was standing water with residual oil on top of it in the dike area. Horse manure was also present from a clean-up effort. The polish rod had vines growing on it. Gas was being vented from the well head. Identification needs to be placed at the well. All fluids need to be removed from dike area. Venting of gas needs to cease or gas needs to be flared. Production needs to be submitted to Columbus for 2010. If the well is not producing or capable of producing, well must be plugged or placed in temporary inactive status. Failure to do so will result in forfeiture of bond. Spoke with Doug Kitchen at 5:03 PM on 5/3/2011 regarding the venting of gas and production status of the well.
1563677384 2009-05-27 Production Wells No Violations A follow-up inspection revealed compliance.
497749856 2009-9-9 0:00:0 AM No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0414227181 US-OH-124403 2011-08-04 Well operation causing pollution and contamination
0414227181 US-OH-124404 2011-08-04 Nonproduction; well shall be plugged or placed in temporary inactive status
1240587779 US-OH-106410 2009-04-24 No SPCC dike/or failure to keep dike free of water or oil
1240587779 US-OH-106411 2009-04-24 Well shall be plugged
1304518233 US-OH-108588 2011-05-04 Forfeiture of bond
1304518233 US-OH-108589 2011-05-04 Failure to legibly identify well
1304518233 US-OH-108590 2011-05-04 No SPCC dike/or failure to keep dike free of water or oil
1304518233 US-OH-108591 2011-05-04 Unlawful venting or flaring of gas
1304518233 US-OH-108592 2011-05-04 Nonproduction; well shall be plugged or placed in temporary inactive status
1304518233 US-OH-108593 2011-05-04 Statement of annual production not filed

For data sources see[8]