If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 34-073-22642 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.46,"lon":-82.45,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Hocking | |
| Municipality: Washington Township | |
| Operator Name: HOCKING HILLS ENERGY AND WELL | |
| Well Pad ID: | |
| Farm/Lease Name: RAUCH NORMA S | |
| License Status: Plugged and Abandoned | |
| License Date: 1999-10-15 | |
| Spud Date: 1982-04-01 | |
| Spud Drilling Contractor: CASPER WELL SVC | |
| Final Drill Date: 1982-04-24 | |
| Well Total Depth: 0.00 ft | |
| Configuration: Vertical | |
| Latitude: 39.460000 | |
| Longitude: -82.450000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| CO | 1982-02-09 | 103 LOPEZ NORMAN H GeoDate 2/9/82 |
| Oil and Gas | 1982-02-09 | Issued Date 2/10/82 Expired Date 8/9/82 Acres 0020530 Tool Type CT Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
| Original Spud | 1982-04-01 | PERMIT EXPIRED. |
| Completed | 1982-04-24 | PERMIT EXPIRED. |
| Reached Total Depth | 1982-04-24 | PERMIT EXPIRED. |
| CO | 1994-11-28 | 1068 COSPER WELL/H COSPER GeoDate 2/9/82 |
| CO | 1995-02-07 | 4074 OIL ENTERPRISES GeoDate 2/9/82 |
| CO | 1996-03-12 | 1675 KILBARGER EDWARD OR ANN GeoDate 2/9/82 |
| CO | 1996-09-09 | 4074 OIL ENTERPRISES GeoDate 2/9/82 |
| CO | 1997-02-20 | 5755 CHIEFTAIN ENERGY CORP. GeoDate 2/9/82 |
| APP | 1999-10-15 | Proposed Formations:CLINTON, Issued Date:10/15/99, Expired Date:10/14/00 6:00:00 AM, Drilling unit acres:20.53, Proposed Well Type:OG, Proposed Well Class: |
| Construction Permit Expires | 2000-10-14 | PERMIT EXPIRED. |
| Plugged/Abandoned | 2000-10-14 | PERMIT EXPIRED. |
| Record Last Modified | 2015-09-24 | PERMIT EXPIRED. |
For data sources see[2]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1992 | BELL DRILLING & PROD CO | 0.00 | 184.00 | 365 |
| 1993 | SHAFER BERMAN J | 0.00 | 64.00 | 52 |
| 1995 | OIL ENTERPRISES | 0.00 | 0.00 | 102 |
| 2006 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
| 2007 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
| 2008 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
| 2009 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
| 2010 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
| 2011 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
| 2012 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1992 | BELL DRILLING & PROD CO | Brine | 35 | 365 |
| 1993 | SHAFER BERMAN J | Brine | 3 | 52 |
| 1995 | OIL ENTERPRISES | Brine | 0 | 102 |
| 2006 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
| 2007 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
| 2008 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
| 2009 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
| 2010 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
| 2011 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
| 2012 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1187993775 | 2008-6-26 0:00: | PW | No Violations | |
| -2026859989 | 2012-9-20 0:00: | FR | No Violations | 2.00 |
| -453627782 | 2011-1-19 0:00: | FR | No Violations | 1.50 |
| -741106062 | 2010-12-30 0:00 | AM | No Violations | |
| -916629854 | 2011-1-19 0:00: | FR | No Violations | 1.50 |
| 0000010055 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 7/8/91 INSPECTOR DAN GOINS DATE 07/0819/91 DATA FROM OLD VAX INFO | |
| 0453627782 | 2011-01-19 | Final Restoration | No Violations | FOLLOW UP TO NOV # 473689052 An inspection revealed that the Final Restoration does not meet ORC 1509.072. Mr. Doug Kitchen, President of Chieftain Energy, has been advised of this deficiency. An electric pole and line were observed at the well site. Approximately 500 of plastic and steel extend from the well site through woods and above ground to a 4 roadside culvert. At this location, the lines disappear and were not found on opposite side of road. Mr. Kitchen has previously stated that a Landowner Waiver had been turned in years ago (1999). No record of this document has been found at Jackson Office. Mr. Kitchen has been verbally instructed to remove or provide a new landowner waiver and submit complete notarized plug report. Division records do not show a plug report for this well. Snow cover at time of inspection. A Compliance Notice will be issued in the Spring, if these deficiencies are not met. |
| 0473689052 | 2011-01-19 | Final Restoration | Violations Noted | An inspection revealed that the Final Restoration does not meet ORC 1509.072. Mr. Doug Kitchen, President of Chieftain Energy, has been advised of this deficiency. An electric pole and line were observed at the well site. Approximately 500 of plastic and steel extend from the well site through woods and above ground to a 4 roadside culvert. At this location, the lines disappear and were not found on opposite side of road. Mr. Kitchen has previously stated that a Landowner Waiver had been turned in years ago (1999). No record of this document has been found at Jackson Office. Mr. Kitchen has been verbally instructed to remove or provide a new landowner waiver and submit complete notarized plug report. Division records do not show a plug report for this well. Snow cover at time of inspection. A Compliance Notice will be issued in the Spring, if these deficiencies are not met. |
| 0741106062 | 2010-12-30 | Administrative Inspection | No Violations | Mr. Ron McBride called this morning at 9:43 am to state that yesterday, Mr. Doug Kitchen accompanied him to this well location. He confirmed flowline and electric remain on property. Mr. McBride states that Mr. Kitchen feels he turned in a landowner waiver and well plugged approx 20 years ago. He was informed of database records showing issuance of 1999 plugging permit however, no plugging report or waiver were located. |
| 0916629854 | 2011-01-19 | Final Restoration | No Violations | FOLLOW UP TO NOV # 473689052 An inspection revealed that the Final Restoration does not meet ORC 1509.072. Mr. Doug Kitchen, President of Chieftain Energy, has been advised of this deficiency. An electric pole and line were observed at the well site. Approximately 500 of plastic and steel extend from the well site through woods and above ground to a 4 roadside culvert. At this location, the lines disappear and were not found on opposite side of road. Mr. Kitchen has previously stated that a Landowner Waiver had been turned in years ago (1999). No record of this document has been found at Jackson Office. Mr. Kitchen has been verbally instructed to remove or provide a new landowner waiver and submit complete notarized plug report. Division records do not show a plug report for this well. Snow cover at time of inspection. A Compliance Notice will be issued in the Spring, if these deficiencies are not met. |
| 10055 | PL | No Violations | ||
| 1187993775 | 2008-06-26 | Production Wells | No Violations | An inspection revealed that this well has been plugged. No plug report found in RBDMS. Chieftain Energy will be contacted and informed that plug report is needed. Files will checked for landowner waiver, due to electric pole & line observed along with flowline. |
| 1299591186 | 2011-03-03 | Final Restoration | Violations Noted | Electric pole with service box is still present. There is still orange plastic line on the ground marked with pink ribbon. ORC 1509.072. Electric pole and orange plastic line needs removed or a land owner waiver needs to be signed. Permit to plug was issued 10/15/1999 and it expired 10/14/2000. Clay tickets, plug reports, and landowner waiver cannot be found. Spoke with Doug Kitchen on 3/3/2011 and told him what I had found and needed taken care of. Plug report needs to be notarized and sent toCentral Office, 2045 Morse Road, Building H Columbus OH 43229-6693 attn. Mike Williams. Spoke with Doug Kitchen on 3/3/2011 and told him what I had found and needed taken care of. |
| 1360204089 | 2011-03-03 | Final Restoration | No Violations | FOLLOW UP TO NOV # 1299591186 Electric pole with service box is still present. There is still orange plastic line on the ground marked with pink ribbon. ORC 1509.072. Electric pole and orange plastic line needs removed or a land owner waiver needs to be signed. Permit to plug was issued 10/15/1999 and it expired 10/14/2000. Clay tickets, plug reports, and landowner waiver cannot be found. Spoke with Doug Kitchen on 3/3/2011 and told him what I had found and needed taken care of. Plug report needs to be notarized and sent toCentral Office, 2045 Morse Road, Building H Columbus OH 43229-6693 attn. Mike Williams. Spoke with Doug Kitchen on 3/3/2011 and told him what I had found and needed taken care of. |
| 1385569805 | 2013-11-27 | Plug / Plug Back | No Violations | Compliance notice follow up. The power pole has been removed, this satisfies the compliance notice. |
| 1965291546 | 2011-01-19 | Final Restoration | No Violations | FOLLOW UP TO NOV # -453627782 FOLLOW UP TO NOV # 473689052 An inspection revealed that the Final Restoration does not meet ORC 1509.072. Mr. Doug Kitchen, President of Chieftain Energy, has been advised of this deficiency. An electric pole and line were observed at the well site. Approximately 500 of plastic and steel extend from the well site through woods and above ground to a 4 roadside culvert. At this location, the lines disappear and were not found on opposite side of road. Mr. Kitchen has previously stated that a Landowner Waiver had been turned in years ago (1999). No record of this document has been found at Jackson Office. Mr. Kitchen has been verbally instructed to remove or provide a new landowner waiver and submit complete notarized plug report. Division records do not show a plug report for this well. Snow cover at time of inspection. A Compliance Notice will be issued in the Spring, if these deficiencies are not met. |
| 2026859989 | 2012-09-20 | Final Restoration | No Violations | Crews have been removing flow line, and cleaning up the site to pass final restoration. I received a call from Mr. Bill Deible at 8:17 am. He stated that the neighboring property owners have been accusing he and his helper of stealing the pipe from the site and someone had left a note for them once again accusing them of stealing pipe from the site. While on site, a tan Ford Escape drove by slowly and a woman yelled from the vehicle and said that she was going to call the sheriff. At that point I contacted Detective Ed Downs of the Hocking county Sherriffs Department and notified him of what was going on and he stated he would take care of it. |
| 473689052 | 2011-1-19 0:00: | FR | No Violations | 1.50 |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 0473689052 | US-OH-125155 | 2011-03-09 | Failure to remove production equip. within 6 mos. REPLACE | |
| 0473689052 | US-OH-125156 | 2011-03-09 | Failure to file plug report in 30 days | |
| 1299591186 | US-OH-108423 | 2011-04-04 | Failure to complete final restoration within six months | |
| 1299591186 | US-OH-108424 | 2011-04-21 | Failure to remove production equip. within 6 mos. REPLACE |
For data sources see[7]