34-073-23431

Well Details

Well ID: 34-073-23431
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Ward Township
Operator Name: MONDAY CREEK RESOURCES LTD
Well Pad ID:
Farm/Lease Name: PRICE - EVANS
License Status: Producing
License Date: 1996-05-19
Spud Date: 1996-05-16
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 1996-05-21
Well Total Depth: 3230.00 ft
Configuration: Vertical
Latitude: 39.550000
Longitude: -82.250000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1995-07-21 Issued Date 7/21/95 Expired Date 7/20/96 Acres 0085000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03230 Proposed Drill Depth 03230
Original Spud 1996-05-16
Annular Disposal Well 1996-05-19
Completed 1996-05-21
Reached Total Depth 1996-05-21
CO 1996-07-05 4646 BOYLE LEO J & HELEN V GeoDate 7/21/95
Construction Permit Expires 1996-07-20
Completion Report Received 1996-11-08
Change of Owner 2006-05-04 Operator changed from 4646, BOYLE LEO J & HELEN V to 8019, MONDAY CREEK RESOURCES LTD
Last Compliance Report 2017-05-09
Record Last Modified 2017-05-09

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1998-01-27 3145 3230 0
3145 3230 0
3145 3230 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1000 Bbl 0 ALSO USED 250 GALLONS OF ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1997 BOYLE LEO J & HELEN V 0.00 104.00 180
1999 BOYLE LEO J & HELEN V 0.00 78.00 148
2000 BOYLE LEO J & HELEN V 0.00 78.00 31
2002 BOYLE LEO J & HELEN V 0.00 0.00 0
2006 MONDAY CREEK RESOURCES LTD 0.00 0.00 0
2007 MONDAY CREEK RESOURCES LTD 0.00 0.00 0
2008 MONDAY CREEK RESOURCES LTD 0.00 151.00 104
2009 MONDAY CREEK RESOURCES LTD 0.00 0.00 52
2010 MONDAY CREEK RESOURCES LTD 0.00 76.00 52
2011 MONDAY CREEK RESOURCES LTD 0.00 73.00 52
2012 MONDAY CREEK RESOURCES LTD 0.00 33.00 52
2013 MONDAY CREEK RESOURCES LTD 0.00 69.00 52
2014 MONDAY CREEK RESOURCES LTD 0.00 48.00 52
2015 MONDAY CREEK RESOURCES LTD 0.00 70.00 52
2016 MONDAY CREEK RESOURCES LTD 0.00 78.00 52
2017 MONDAY CREEK RESOURCES LTD 0.00 88.00 365
2018 MONDAY CREEK RESOURCES LTD 0.00 88.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1997 BOYLE LEO J & HELEN V Brine 456 180
1999 BOYLE LEO J & HELEN V Brine 318 148
2000 BOYLE LEO J & HELEN V Brine 0 31
2002 BOYLE LEO J & HELEN V Brine 0 0
2006 MONDAY CREEK RESOURCES LTD Brine 0 0
2007 MONDAY CREEK RESOURCES LTD Brine 0 0
2008 MONDAY CREEK RESOURCES LTD Brine 0 104
2009 MONDAY CREEK RESOURCES LTD Brine 0 52
2010 MONDAY CREEK RESOURCES LTD Brine 0 52
2011 MONDAY CREEK RESOURCES LTD Brine 0 52
2012 MONDAY CREEK RESOURCES LTD Brine 0 52
2013 MONDAY CREEK RESOURCES LTD Brine 0 52
2014 MONDAY CREEK RESOURCES LTD Brine 0 52
2015 MONDAY CREEK RESOURCES LTD Brine 0 52
2016 MONDAY CREEK RESOURCES LTD Brine 0 52
2017 MONDAY CREEK RESOURCES LTD Brine 0 365
2018 MONDAY CREEK RESOURCES LTD Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1214822996 2017-4-4 0:00:0 PW No Violations 4.00
-1227585917 2004-7-8 0:00:0 AD No Violations
-1685111926 2019-5-30 0:00: PW No Violations 0.50
-1793198279 2006-12-11 0:00 AD No Violations
-308916906 2007-4-4 0:00:0 AD No Violations
-738563382 2009-2-5 0:00:0 AD No Violations
-841041853 2020-3-25 0:00: PW No Violations 2.00
01269i1388 2002-09-19 Preliminary Restoration No Violations Restoration meets 1509.072(A) requirements
0308916906 2007-04-04 Annular Disposal No Violations A mechancial integrity test (PDT) was peformed on 4/4/2007. The well did not pass the required test.
0738563382 2009-02-05 Annular Disposal Violations Noted An inspection of the well revealed that gas is being vented without the use of a flare. It was also noted that the AD remains disconnected. The identification placed at the tank battery (common) has faded and will need to be addressed.
1079308071 2004-03-11 Annular Disposal Violations Noted An inspection of the well revealed ID not complete at well or tank battery, AD hooked up.
1091541059 2009-04-06 Production Wells No Violations A follow-up inspection revealed that the well is in-compliance.
1214822996 2017-04-04 Production Wells No Violations I received a notice from Division of Oil and Gas emergency response department regarding this well. They received a report from a individual who stated the well was leaking gas. This report came in on 4-3-2017 at approximately 1300 hours. I received the notice at 1535 hours. I checked the well today for compliance and found the well was venting gas thru a approved relief device. The well had a legible identification posted.
1227585917 2004-07-08 Annular Disposal No Violations In-Compliance
1269i1388 2002-9-19 0:00: PL No Violations
1269i26509 2001-02-14 Production Wells No Violations NO VIOLATIONS.
1269i2650939 2001-2-14 0:00: PW No Violations
1348848617 2012-09-27 Annular Disposal No Violations Checked annular disposal for Columbus. It is not being used.
1685111926 2019-05-30 Production Wells No Violations Upon arriving at 7:45 AM, I walked to the well and found a well with a pumping unit. The tubing and casing wellhead valves were in the open position. The well was equipped with an approved venting device. The venting device was not in compliance with 1501:9-9-05(B). The venting device was allowing natural gas to escape continually instead of allowing the well to build gas pressure and release the gas pressure at given intervals. The well was equipped with a flare that was not being used. The owner of the well shall set the approved venting device to allow the release of the natural gas pressure at intervals instead of continually or the owner of the well shall use the flair that was constructed to allow the natural gas to burned off.
1697223438 2019-8-8 0:00:0 PW No Violations 0.30
1766039063 2017-04-19 Temporary Abandoned Annular Disposal No Violations I received a request from Central Office to determine if this well is being used for annular disposal. The well is not being used for annular disposal.
1793198279 2006-12-11 Annular Disposal No Violations Checked AD for Columbus on 12/11/2006. AD not hooked up.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0738563382 US-OH-128396 2009-03-09 Failure to legibly identify well
0738563382 US-OH-128397 2009-03-09 Unlawful venting or flaring of gas
1079308071 US-OH-101724 2004-03-14 Failure to legibly identify well

For data sources see[9]

References