34-073-23441

Well Details

Well ID: 34-073-23441
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Marion Township
Operator Name: R C POLING CO INC
Well Pad ID:
Farm/Lease Name: CAMP AKITA # 2
License Status: Producing
License Date: 1996-11-22
Spud Date: 1997-03-03
Spud Drilling Contractor: OHIO ENERGY ASSETS
Final Drill Date: 1997-03-12
Well Total Depth: 4241.00 ft
Configuration: Vertical
Latitude: 39.610000
Longitude: -82.480000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1996-05-17 236 POLING R C CO INC GeoDate 5/17/96
Oil and Gas 1996-05-17 Issued Date 5/17/96 Expired Date 5/17/97 Acres 0040000 Tool Type RTAF Proposed Formation KNOX Proposed Depth Proposed Drill Depth
CO 1996-11-22 236 POLING R C CO INC GeoDate 11/22/96
Oil and Gas 1996-11-22 Issued Date 11/22/96 Expired Date 11/22/97 Acres 0040000 Tool Type RTAF Proposed Formation KNOX Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1997-03-03 RBDMS Rec
Completed 1997-03-12 RBDMS Rec
Reached Total Depth 1997-03-12 RBDMS Rec
Completion Report Received 1997-11-14 RBDMS Rec
Construction Permit Expires 1997-11-22 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1997 R C POLING CO INC 16766.00 19016.00 365
1998 R C POLING CO INC 6699.00 6521.00 365
1999 R C POLING CO INC 1587.00 1981.00 365
2000 R C POLING CO INC 2280.00 2571.00 365
2001 R C POLING CO INC 6016.00 3888.00 365
2002 R C POLING CO INC 855.00 1347.00 365
2003 R C POLING CO INC 1846.00 973.00 365
2004 R C POLING CO INC 1062.00 961.00 365
2005 R C POLING CO INC 951.00 412.00 365
2006 R C POLING CO INC 305.00 269.00 365
2007 R C POLING CO INC 76.00 150.00 365
2008 R C POLING CO INC 43.00 221.00 365
2009 R C POLING CO INC 194.00 142.00 365
2013 R C POLING CO INC 0.00 224.00 365
2014 R C POLING CO INC 0.00 123.00 365
2015 R C POLING CO INC 0.00 159.00 365
2016 R C POLING CO INC 0.00 107.00 365
2017 R C POLING CO INC 0.00 115.00 365
2018 R C POLING CO INC 0.00 90.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1997 R C POLING CO INC Brine 0 365
1998 R C POLING CO INC Brine 131 365
1999 R C POLING CO INC Brine 534 365
2000 R C POLING CO INC Brine 503 365
2001 R C POLING CO INC Brine 1625 365
2002 R C POLING CO INC Brine 1532 365
2003 R C POLING CO INC Brine 560 365
2004 R C POLING CO INC Brine 674 365
2005 R C POLING CO INC Brine 175 365
2006 R C POLING CO INC Brine 290 365
2007 R C POLING CO INC Brine 80 365
2008 R C POLING CO INC Brine 80 365
2009 R C POLING CO INC Brine 150 365
2013 R C POLING CO INC Brine 0 365
2014 R C POLING CO INC Brine 0 365
2015 R C POLING CO INC Brine 63 365
2016 R C POLING CO INC Brine 0 365
2017 R C POLING CO INC Brine 0 365
2018 R C POLING CO INC Brine 40 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1100577017 2008-3-26 0:00: PW No Violations
-1312141861 2019-5-2 0:00:0 PW No Violations 1.00
-1619924858 2019-4-17 0:00: PW No Violations 0.40
-1762635727 2013-10-9 0:00: PW No Violations 2.50
-353197315 2019-6-27 0:00: PW No Violations 0.10
-445722883 2003-12-18 0:00 PW No Violations
-79332847 2008-9-3 0:00:0 PW No Violations
0022096419 2008-08-19 Production Wells Violations Noted An inspection revealed contamination and pollution inside the earthen dike. No identification observed at the wellhead (common tank battery).
0079332847 2008-09-03 Production Wells No Violations A follow-up inspection revaled non-compliance.
0445722883 2003-12-18 Production Wells No Violations Follow-up on NOV, Non-Compliance,spoke to company will have corrected by first of year.
0518229669 2009-04-09 Production Wells No Violations A follow-up inspection revealed compliance.
0541794358 2004-02-04 Production Wells No Violations Follow-up on NOV, In-Compliance.
0920006642 2004-03-11 Preliminary Restoration No Violations Restoration meets 1509(A) requirements.
1100577017 2008-03-26 Production Wells Violations Noted An inspection revealed no identification at the well and tank battery (common). C&P observed at the well head, and around the separator. It was also noted that the fluid level inside dike was high and contained oil. Mr. Dick Poling was contacted and informed of the inspection results.
1179304243 2003-10-27 Production Wells Violations Noted An inspection of the well revealed no ID at well, C&P around well and production tanks, bare area on well site. 10/27/03 Follow-up on NOV, Non-Compliance, no action to comply with NOV.
1312141861 2019-05-02 Production Wells No Violations My inspection revealed that the oil has been cleaned up from the dike. Identification has been posted at the tank battery. I did not observe identification at the well. I contacted Zach Poling at 9:23 AM. I advised Zach that the clean up was complete but identification has not been posted at the well. Zach said he would have his pumper post identification as soon as he could. The violation will be resolved once identification is posted. Time of inspection: 8:00 AM. Weather: 64 degrees F, Cloudy
1617294964 2019-02-14 Production Wells No Violations My inspection revealed that the well was equipped with a pumping unit and electric motor. The well was enclosed within a chain link fence. This well produces into a shared tank battery with API permit number 3460. The tank battery consists of (2) 210 barrel tanks inside an earthen dike. I did not observe identification at the well or tank battery. During my inspection of the tank battery I observed oil contamination inside the dike that was trapped in a layer of ice across the dike. I took several photos of the oil contamination. The well owner shall remove the oil contamination once the ice thaws and post identification within 10 days at the well and tank battery. I contacted Zach Poling at 2:45 PM and advised him of the violations. Time of inspection: 2:00 PM. Weather: 45 degrees F, Overcast
1619924858 2019-04-17 Production Wells No Violations I conducted a compliance notice follow-up at the tank battery. The oil has not been cleaned up from within the dike. I observed saturated oil absorbent pads that need to be removed. I took several photos of the oil during the inspection. I left a voicemail message for Zach Poling at 9:38 AM and advised him of my follow-up inspection. Time of inspection: 8:00 AM. Weather: 50 degrees F, Partly cloudy
1621969689 2019-03-28 Production Wells No Violations My inspection of the tank battery revealed that the oil has not been cleaned up. The water level that was in the dike has been pumped down and allowed the oil move to the perimeter of the dike wall. It appears that some clean up has taken place as I observed absorbent pads in the oil. The pads were completely saturated and need removed. I took several photos of the tank battery. I left a voicemail message for Zach Poling at 9:07 AM. Time of inspection: 8:15 AM. Weather: 32 degrees F, Sunny
1762635727 2013-10-09 Production Wells No Violations Production well inspection, this well consists of a pumping unit and 4-210 barrel tanks. There is a small amount of oil around the well head. I have contacted RC Poling company to have this corrected.
22096419 2008-8-19 0:00: PW No Violations
518229669 2009-4-9 0:00:0 PW No Violations
541794358 2004-2-4 0:00:0 PW No Violations
920006642 2004-3-11 0:00: PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0022096419 US-OH-122198 2008-08-22 Failure to legibly identify well
0022096419 US-OH-122199 2008-08-22 No SPCC dike/or failure to keep dike free of water or oil
1100577017 US-OH-102441 2008-04-07 Well operation causing pollution and contamination
1100577017 US-OH-102442 2008-04-07 Failure to legibly identify well
1100577017 US-OH-102443 2008-04-07 No SPCC dike/or failure to keep dike free of water or oil
1179304243 US-OH-104779 2003-09-15 Well operation causing pollution and contamination
1179304243 US-OH-104780 2003-09-15 Failure to legibly identify well
1179304243 US-OH-104781 2003-09-15 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[7]

References