34-073-60110

Well Details

Well ID: 34-073-60110
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Benton Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: SAMUEL EVELAND ETAL
License Status: Final Restoration
License Date: 2010-10-13
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1921-04-24
Well Total Depth: 2353.00 ft
Configuration: Vertical
Latitude: 39.420000
Longitude: -82.600000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1921-04-24 WELL IS ON COLUMBIA'S 2005 REHAB LIST PF=PAY
Reached Total Depth 1921-04-24 WELL IS ON COLUMBIA'S 2005 REHAB LIST PF=PAY
APP 2010-10-13 Proposed Formations:CLINTON, Issued Date:10/13/2010, Expired Date:10/12/2012 12:00:00 PM, Drilling unit acres:205, Proposed Well Type:SO, Proposed Well Class:
Plugged/Abandoned 2010-12-20 WELL IS ON COLUMBIA'S 2005 REHAB LIST PF=PAY
Construction Permit Expires 2012-10-12 WELL IS ON COLUMBIA'S 2005 REHAB LIST PF=PAY
Record Last Modified 2013-03-14 WELL IS ON COLUMBIA'S 2005 REHAB LIST PF=PAY

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-218173724 2010-12-15 0:00 PB No Violations 7.00
-308350216 2011-9-15 0:00: FR No Violations
0105668171 2010-12-20 Plug / Plug Back No Violations Witnessed plugging and abandonment. Pumped cement inside 3.5 csg from 1790 to 1000 for Lime plug. Perforated at 770 (6 shots) and set 3.5 cement retainer at 753 then perforated again at 300 (6 shots). Stabbed into retainer with stinger. Pump pressure reached 1250lb w/no estbl circulation and unable to squeeze w/ stinger. Therefore, we would now rely on hydrostatic pressure and stabbed-out of retainer to pump 4bbl of cement to 315. Pulled 15 joints. Closed return line on BOP w/initial circulation and pumped 0.75 bbl cement w/pressure of over 800 lbs. Opened line and observed cement returns. TOH. Cement dropped and unable to visually see. Topped off to surface. The above procedures were done with the idea that at least hydrostatic would assist with squeezing of cement on backside of casing to seal Berea formation. Background: Set a 600 bottom hole plug on 12/15/2010, through 2.063 tubing (inside 3.5 casing cemented to surface). Note: Columbia records had showed 3.5 csg to surface inside un-cemented 5.5 csg; and 7 csg left from 534-782 w/lead BH packer also not cemented and placed across the Berea. In the 1960s, the 5.5csg was perforated and cemented from 210 to surface. Recent new drill for Columbia, Permit No. 3596 showed freshwater at 405. No casing would be retrieved from this plug job.
0218173724 2010-12-15 Plug / Plug Back No Violations Witnessed kill procedure with 20.5 bbl saltwater (morning) and bottom hole plug (afternoon).
0308350216 2011-09-15 Final Restoration No Violations Restoration meets 1509.072 requirements. Lease road is still used for access to existing storage well.
105668171 2010-12-20 0:00 PB No Violations 8.00

For data sources see[4]