Well Details

Well ID: 34-073-61175
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Laurel Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: VORHEES MYRTLE
License Status: Storage Well
License Date:
Spud Date: 1951-06-22
Spud Drilling Contractor:
Final Drill Date: 1951-07-24
Well Total Depth: 2421.00 ft
Configuration: Vertical
Latitude: 39.480000
Longitude: -82.570000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1951-06-22 GL=1037.5, STORAGE
Completed 1951-07-24 GL=1037.5, STORAGE
Reached Total Depth 1951-07-24 GL=1037.5, STORAGE
Change of Owner 2011-08-19 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-09-06 GL=1037.5, STORAGE

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1203630298 2018-12-5 0:00: SO No Violations 0.30
-1277384703 2014-6-17 0:00: SO No Violations 1.00
-1492690428 2014-4-7 0:00:0 SO No Violations 0.30
-2086952418 2014-4-7 0:00:0 SO No Violations 0.30
-842360861 2016-11-7 0:00: SO No Violations 1.00
0026942586 2015-09-03 Storage Well No Violations Storage well inspection. Legible well identification found at well. No violations found on date of inspection.
0842360861 2016-11-07 Storage Well No Violations Columbia Gas storage well inspection. The well consists of a wellhead and drip. Legible identification was posted. No violations.
1020815391 2014-05-15 Storage Well No Violations Upon inspection, it was observed that there has been no change in the I.D. information for this well. I spoke with CGT Well Technician Rich Fuller and he stated that they have all the new I.D. tags made up and they will be posting them as they come to each well that needs updated identification.
1068202876 2020-4-24 0:00: SO No Violations 0.30
1203630298 2018-12-05 Storage Well No Violations I conducted a storage well inspection on this well today. I observed identification at the drip. I did not observe any violations. Time of inspection: 3:35 PM. Weather: 32 degrees, Mostly cloudy
1277384703 2014-06-17 Storage Well No Violations Storage well inspection. The well has legible and correct identification, the well is in compliance.
1492690428 2014-04-07 Storage Well Violations Noted Upon inspection, this well was equipped with a well head and a drip. There were no tanks associated with this well. There was legible identification information posted, but the API number is inaccurate. Rich Fuller and Josh Williams of Columbia Gas Transmission have been notified of the situation.
2086952418 2014-04-07 Storage Well No Violations FOLLOW UP TO NOV # -1492690428 Upon inspection, this well was equipped with a well head and a drip. There were no tanks associated with this well. There was legible identification information posted, but the API number is inaccurate. Rich Fuller and Josh Williams of Columbia Gas Transmission have been notified of the situation.
2143135025 2017-08-29 Storage Well No Violations Columbia Gas storage well inspection. The well consists of a wellhead and a drip. Legible identification on wellhead, no violations noted, GPS was taken on day of inspection.
26942586 2015-9-3 0:00:0 SO No Violations 1.00
364905723 2019-10-17 0:00 SO No Violations 0.20

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1492690428 US-OH-113924 2014-04-10 Failure to legibly identify well