X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-075-21986

Well Details

Well ID: 34-075-21986
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Knox Township
Operator Name: DILLON JOHN C
Well Pad ID:
Farm/Lease Name: DOTY DALE
License Status: Producing
License Date: 2006-07-11
Spud Date: 1977-07-17
Spud Drilling Contractor:
Final Drill Date: 1978-01-12
Well Total Depth: 3080.00 ft
Configuration: Vertical
Latitude: 40.550000
Longitude: -82.120000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1977-07-13 185 HILL WILLIAM F GeoDate 7/13/77
Original Spud 1977-07-17
Completed 1978-01-12
Reached Total Depth 1978-01-12
CO 1993-05-10 4280 JRD ENERGY GeoDate 7/13/77
Change of Owner 1999-03-10 Operator changed from 4280, JRD ENERGY to 627, KENOIL
APP 2006-07-11 Proposed Formations:CLINTON, Issued Date:7/11/2006, Expired Date:7/11/2007 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2007-07-11
Change of Owner 2007-10-29 Operator changed from 627, KENOIL to 6160, DILLON JOHN C
Record Last Modified 2013-10-03

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 25000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 HILL WILLIAM F 0.00 227.00 0
1986 HILL WILLIAM F 0.00 218.00 365
1987 HILL WILLIAM F 0.00 225.00 365
1988 HILL WILLIAM F 0.00 156.00 365
1989 HILL WILLIAM F 0.00 223.00 365
1990 HILL WILLIAM F 0.00 138.00 365
1991 HILL WILLIAM F 0.00 135.00 365
1992 HILL WILLIAM F 0.00 188.00 365
1993 HILL WILLIAM F 0.00 67.00 120
1994 JRD ENERGY 0.00 80.00 365
1995 JRD ENERGY 0.00 153.00 365
1996 JRD ENERGY 0.00 76.00 365
1998 JRD ENERGY 0.00 80.00 119
1999 KENOIL LLC 0.00 0.00 0
2000 KENOIL LLC 0.00 323.00 365
2001 KENOIL LLC 0.00 286.00 365
2002 KENOIL LLC 0.00 73.00 365
2003 KENOIL LLC 0.00 70.00 365
2004 KENOIL LLC 0.00 133.00 365
2005 KENOIL LLC 0.00 72.00 365
2006 KENOIL LLC 0.00 70.00 365
2008 KENOIL LLC 0.00 56.00 365
2014 DILLON JOHN C 0.00 72.00 365
2015 DILLON JOHN C 0.00 75.00 365
2016 DILLON JOHN C 0.00 67.00 365
2017 DILLON JOHN C 0.00 57.00 365
2018 DILLON JOHN C 0.00 110.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 HILL WILLIAM F Brine 0 0
1986 HILL WILLIAM F Brine 35 365
1987 HILL WILLIAM F Brine 0 365
1988 HILL WILLIAM F Brine 0 365
1989 HILL WILLIAM F Brine 0 365
1990 HILL WILLIAM F Brine 55 365
1991 HILL WILLIAM F Brine 0 365
1992 HILL WILLIAM F Brine 0 365
1993 HILL WILLIAM F Brine 15 120
1994 JRD ENERGY Brine 0 365
1995 JRD ENERGY Brine 0 365
1996 JRD ENERGY Brine 0 365
1998 JRD ENERGY Brine 82 119
1999 KENOIL LLC Brine 11
2000 KENOIL LLC Brine 120 365
2001 KENOIL LLC Brine 0 365
2002 KENOIL LLC Brine 0 365
2003 KENOIL LLC Brine 8 365
2004 KENOIL LLC Brine 0 365
2005 KENOIL LLC Brine 35 365
2006 KENOIL LLC Brine 0 365
2008 KENOIL LLC Brine 0 365
2014 DILLON JOHN C Brine 0 365
2015 DILLON JOHN C Brine 0 365
2016 DILLON JOHN C Brine 0 365
2017 DILLON JOHN C Brine 0 365
2018 DILLON JOHN C Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-976483257 2012-8-8 0:00:0 PW No Violations
0006549875 2016-10-24 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
0213053678 2015-10-20 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
0976483257 2012-08-08 Production Wells Violations Noted This is a producing pump jack well. The identification is missing the Owner Name and an emergency number as required by law. There is no owner phone number on file. The heater tube on the Low (Left) tank is leaking oil. Affix a legible identification sign to include the name of the owner, the name of the well, the number of the well, the County name and a phone number to call in case of emergency. Also put a plug in the heater tube of the leaking tank. Questions? Call the inspector at 614 264-5850. There were no other problems noted at the time of the inspection.
1563974812 2019-7-24 0:00: PW No Violations
1657848710 2013-03-04 Production Wells No Violations The tank heater tube has been plugged and a valid Id has been affixed to the tank. The compliance Notice of 8/9/2012 has been satisfied. There were no problems noted at the time of the inspection.
1780967545 2018-05-04 Production Wells No Violations On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing a 1 1/2 inch diameter tubing. The well is operated by a pumping unit with an electric motor. The production equipment is made up of two 100 bbl. steel tanks, a 50 bbl. steel tank. The tank is properly identified. The production reporting is up to date.
1997414860 2019-11-7 0:00: PW No Violations 0.30
213053678 2015-10-20 0:00 PW No Violations
6549875 2016-10-24 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0976483257 US-OH-131212 2013-03-05 Well operation causing pollution and contamination
0976483257 US-OH-131213 2013-03-05 Failure to legibly identify well

For data sources see[8]

References