34-075-23414

Well Details

Well ID: 34-075-23414
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Tiverton Township
Operator Name: HAWKINS GENE
Well Pad ID:
Farm/Lease Name: HAWKINS HELEN
License Status: Domestic Well
License Date: 1982-04-01
Spud Date: 1982-04-02
Spud Drilling Contractor:
Final Drill Date: 1982-04-15
Well Total Depth: 3400.00 ft
Configuration: Vertical
Latitude: 40.450000
Longitude: -82.110000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-04-01 Issued Date 4/2/82 Expired Date Acres 0183120 Tool Type RTA Proposed Formation CLINTON Proposed Depth Proposed Drill Depth
Original Spud 1982-04-08
Completed 1982-04-15
Reached Total Depth 1982-04-15
CO 1982-06-18 3544 HAWKINS GENE GeoDate 4/1/82
Construction Permit Expires 1982-09-29
Completion Report Received 1986-05-07
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3268 3296 14
3268 3296 14
3268 3296 14

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1150 Bbl 45000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 B J INC 1578.00 206.00 0
1985 B-J OF OHIO INC 853.00 53.00 365
1988 B-J OF OHIO INC 577.00 64.00 344

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 B J INC Brine 131 0
1985 B-J OF OHIO INC Brine 120 365
1988 B-J OF OHIO INC Brine 0 344

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
000PL15823 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1831022341 2018-05-16 Production Wells No Violations On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, 2 3/8 inch diameter tubing, operated by a pumping unit with an electric motor. This is domestic well. There are two 100 bbl. tanks. The heater tube on the 100 bbl. tank is leaking. I placed a phone call to Gene Hawkins to make repairs and clean up around the tanks.
PL15823 PL No Violations

For data sources see[9]