X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-075-24569

Well Details

Well ID: 34-075-24569
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Salt Creek Township
Operator Name: W H PATTEN DRILLING CO
Well Pad ID:
Farm/Lease Name: FEIKERT
License Status: Producing
License Date: 1985-07-01
Spud Date: 1985-08-12
Spud Drilling Contractor: CAMPHIRE DRILLING
Final Drill Date: 1985-09-10
Well Total Depth: 3575.00 ft
Configuration: Vertical
Latitude: 40.610000
Longitude: -81.870000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1985-07-01 Issued Date 7/1/85 Expired Date 7/1/86 Acres 0091000 Tool Type CT Proposed Formation CLINTON Proposed Depth 03575 Proposed Drill Depth 03575
Original Spud 1985-08-12
Completed 1985-09-10
Reached Total Depth 1985-09-10
CO 1985-10-14 64 BUCKEYE FRANKLIN CO GeoDate 7/1/85
Completion Report Received 1985-10-28
Construction Permit Expires 1986-07-01
Change of Owner 1997-11-14 Operator changed from 64, BUCKEYE FRANKLIN CO to 56, BUCKEYE OIL PRODUCING CO
Change of Owner 2003-11-03 Operator changed from 56, BUCKEYE OIL PRODUCING CO to 372, PATTEN W H DRLG CO
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3496 3516 11
3578 3564 0
1997-06-29 3578 3564 0
3496 3516 11
3496 3516 11

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 FRAC;H2O

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 BUCKEYE FRANKLIN CO 330.00 78.00 78
1986 BUCKEYE FRANKLIN CO 1468.00 731.00 365
1987 BUCKEYE FRANKLIN CO 1651.00 1780.00 365
1988 BUCKEYE FRANKLIN CO 3822.00 1002.00 365
1989 BUCKEYE FRANKLIN CO 5428.00 1779.00 365
1990 BUCKEYE FRANKLIN CO 3230.00 1096.00 365
1991 BUCKEYE FRANKLIN CO 3471.00 746.00 365
1992 BUCKEYE FRANKLIN CO 2371.00 519.00 365
1993 BUCKEYE FRANKLIN CO 2000.00 414.00 365
1994 BUCKEYE FRANKLIN CO 2059.00 398.00 365
1995 BUCKEYE FRANKLIN CO 2317.00 473.00 365
1996 BUCKEYE FRANKLIN CO 1584.00 233.00 365
1997 BUCKEYE OIL PRODUCING CO 1569.00 308.00 365
1998 BUCKEYE OIL PRODUCING CO 580.00 77.00 365
1999 BUCKEYE OIL PRODUCING CO 728.00 265.00 0
2000 BUCKEYE OIL PRODUCING CO 417.00 139.00 0
2001 BUCKEYE OIL PRODUCING CO 553.00 142.00 365
2002 BUCKEYE OIL PRODUCING CO 604.00 145.00 365
2003 W H PATTEN DRILLING CO 528.00 0.00 61
2004 W H PATTEN DRILLING CO 756.00 71.00 365
2005 W H PATTEN DRILLING CO 538.00 71.00 365
2006 W H PATTEN DRILLING CO 565.00 71.00 365
2007 W H PATTEN DRILLING CO 605.00 72.00 365
2008 W H PATTEN DRILLING CO 598.00 68.00 365
2009 W H PATTEN DRILLING CO 336.00 78.00 365
2010 W H PATTEN DRILLING CO 49.00 0.00 365
2011 W H PATTEN DRILLING CO 297.00 73.00 365
2012 W H PATTEN DRILLING CO 0.00 78.00 366
2013 W H PATTEN DRILLING CO 48.00 0.00 365
2014 W H PATTEN DRILLING CO 67.00 77.00 365
2015 W H PATTEN DRILLING CO 8.00 0.00 365
2016 W H PATTEN DRILLING CO 15.00 0.00 365
2017 W H PATTEN DRILLING CO 5.00 70.00 365
2018 W H PATTEN DRILLING CO 10.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 BUCKEYE FRANKLIN CO Brine 0 78
1986 BUCKEYE FRANKLIN CO Brine 0 365
1987 BUCKEYE FRANKLIN CO Brine 600 365
1988 BUCKEYE FRANKLIN CO Brine 20 365
1989 BUCKEYE FRANKLIN CO Brine 0 365
1990 BUCKEYE FRANKLIN CO Brine 60 365
1991 BUCKEYE FRANKLIN CO Brine 0 365
1992 BUCKEYE FRANKLIN CO Brine 45 365
1993 BUCKEYE FRANKLIN CO Brine 45 365
1994 BUCKEYE FRANKLIN CO Brine 45 365
1995 BUCKEYE FRANKLIN CO Brine 0 365
1996 BUCKEYE FRANKLIN CO Brine 45 365
1997 BUCKEYE OIL PRODUCING CO Brine 135 365
1998 BUCKEYE OIL PRODUCING CO Brine 365
1999 BUCKEYE OIL PRODUCING CO Brine 85
2000 BUCKEYE OIL PRODUCING CO Brine 40
2001 BUCKEYE OIL PRODUCING CO Brine 35 365
2002 BUCKEYE OIL PRODUCING CO Brine 45 365
2003 BUCKEYE OIL PRODUCING CO Brine 40 304
2004 W H PATTEN DRILLING CO Brine 0 365
2005 W H PATTEN DRILLING CO Brine 30 365
2006 W H PATTEN DRILLING CO Brine 0 365
2007 W H PATTEN DRILLING CO Brine 45 365
2008 W H PATTEN DRILLING CO Brine 0 365
2009 W H PATTEN DRILLING CO Brine 0 365
2010 W H PATTEN DRILLING CO Brine 40 365
2011 W H PATTEN DRILLING CO Brine 0 365
2012 W H PATTEN DRILLING CO Brine 35 366
2013 W H PATTEN DRILLING CO Brine 42 365
2014 W H PATTEN DRILLING CO Brine 0 365
2015 W H PATTEN DRILLING CO Brine 35 365
2016 W H PATTEN DRILLING CO Brine 25 365
2017 W H PATTEN DRILLING CO Brine 0 365
2018 W H PATTEN DRILLING CO Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-560422060 2019-5-29 0:00: PW No Violations
-639422295 2020-6-19 0:00: PW No Violations 0.50
000PL15217 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0114883836 2012-09-17 Production Wells No Violations This is a producing pump jack well. There was no ID on the tank or well. Called the operator for a valid legible ID. He will comply. There were no other problems noted at the time of the inspection.
0560422060 2019-05-29 Production Wells No Violations On the day of my inspection I found an 8 5/8-inch diameter casing, a 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing and rods. The well is operated by a pumping unit with an electric motor system. The production equipment is made up of one 100 bbl. steel tank, a concrete vault, and a vertical separator. The tank is properly identified. The production reporting is up to date.
114883836 2012-9-17 0:00: PW No Violations
1294946124 2018-02-16 Production Wells No Violations On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 2 3/8 inch diameter tubing. The well is operated by a pumping unit with an electric motor system. The production equipment is made up of one 100 bbl. steel tank, a concrete vault, and a vertical separator. The tank is properly identified. The production reporting is up to date.
139111199 2020-8-10 0:00: PW No Violations 0.30
1603676839 2019-11-12 0:00 PW No Violations 0.30
1887792156 2015-07-28 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
2129699189 2013-11-19 Production Wells No Violations The ID sign is in place. The Compliance Notice of 9/17/12 is satisfied. This pump jack well is producing, there were no problems noted.
PL15217 PL No Violations

For data sources see[9]

References