If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-075-25122 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.56,"lon":-81.93,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Holmes | |
Municipality: Hardy Township | |
Operator Name: MASON PRODUCING INC | |
Well Pad ID: | |
Farm/Lease Name: HIPP ETAL | |
License Status: Producing | |
License Date: 1993-08-03 | |
Spud Date: 1993-08-22 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 1993-08-31 | |
Well Total Depth: 5700.00 ft | |
Configuration: Vertical | |
Latitude: 40.560000 | |
Longitude: -81.930000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1993-08-03 | Issued Date 8/3/93 Expired Date 8/3/94 Acres 0099000 Tool Type RTAF Proposed Formation COPPER RIDGE Proposed Depth 05700 Proposed Drill Depth 05700 |
Original Spud | 1993-08-22 | |
Completed | 1993-08-31 | |
Reached Total Depth | 1993-08-31 | |
CO | 1993-10-29 | 1983 MASON DRILLING INC GeoDate 8/3/93 |
Completion Report Received | 1993-11-15 | |
Construction Permit Expires | 1994-08-03 | |
Change of Owner | 2002-12-30 | Operator changed from 1983, MASON DRILLING INC to 7333, MASON PRODUCING |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5460 | 5475 | 13 |
5444 | 5552 | 0 | |
1997-06-29 | 5444 | 5552 | 0 |
5222 | 5226 | 9 | |
5222 | 5226 | 9 | |
2006-09-11 | 5442 | 5452 | 17 |
2006-09-11 | 5480 | 5498 | 37 |
2006-09-11 | 5432 | 5438 | 13 |
2006-09-11 | 5222 | 5226 | 9 |
2006-09-11 | 5546 | 5550 | 9 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 3000 Gal | 0 | TREATED W/3000 GAL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1993 | MASON DRILLING INC | 0.00 | 86.00 | 122 |
1994 | MASON DRILLING INC | 144796.00 | 1911.00 | 365 |
1995 | MASON DRILLING INC | 90777.00 | 1202.00 | 365 |
1996 | MASON DRILLING INC | 148728.00 | 1426.00 | 365 |
1997 | MASON DRILLING INC | 116973.00 | 1030.00 | 365 |
1998 | MASON DRILLING INC | 98668.00 | 681.00 | 365 |
1999 | MASON DRILLING INC | 91728.00 | 839.00 | 365 |
2000 | MASON DRILLING INC | 101897.00 | 863.00 | 0 |
2001 | MASON DRILLING INC | 111059.00 | 762.00 | 365 |
2002 | MASON PRODUCING INC | 706.00 | 0.00 | 31 |
2003 | MASON DRILLING INC | 0.00 | 0.00 | 365 |
2004 | MASON PRODUCING INC | 25390.00 | 483.00 | 365 |
2005 | MASON PRODUCING INC | 25334.00 | 251.00 | 365 |
2006 | MASON PRODUCING INC | 25264.00 | 405.00 | 365 |
2007 | MASON PRODUCING INC | 16571.00 | 270.00 | 365 |
2008 | MASON PRODUCING INC | 14877.00 | 254.00 | 366 |
2009 | MASON PRODUCING INC | 11431.00 | 252.00 | 365 |
2010 | MASON PRODUCING INC | 8053.00 | 271.00 | 365 |
2011 | MASON PRODUCING INC | 7269.00 | 255.00 | 365 |
2012 | MASON PRODUCING INC | 6034.00 | 255.00 | 366 |
2013 | MASON PRODUCING INC | 5737.00 | 173.00 | 365 |
2014 | MASON PRODUCING INC | 4167.00 | 190.00 | 365 |
2015 | MASON PRODUCING INC | 4696.00 | 276.00 | 365 |
2016 | MASON PRODUCING INC | 3769.00 | 138.00 | 365 |
2017 | MASON PRODUCING INC | 3118.00 | 235.00 | 365 |
2018 | MASON PRODUCING INC | 5437.00 | 215.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1993 | MASON DRILLING INC | Brine | 84 | 122 |
1994 | MASON DRILLING INC | Brine | 703 | 365 |
1995 | MASON DRILLING INC | Brine | 905 | 365 |
1996 | MASON DRILLING INC | Brine | 1156 | 365 |
1997 | MASON DRILLING INC | Brine | 1117 | 365 |
1998 | MASON DRILLING INC | Brine | 1449 | 365 |
1999 | MASON DRILLING INC | Brine | 1336 | 365 |
2000 | MASON DRILLING INC | Brine | 1077 | |
2001 | MASON DRILLING INC | Brine | 16 | 365 |
2002 | MASON DRILLING INC | Brine | 1007 | 334 |
2003 | MASON DRILLING INC | Brine | 0 | 365 |
2004 | MASON PRODUCING INC | Brine | 1072 | 365 |
2005 | MASON PRODUCING INC | Brine | 925 | 365 |
2006 | MASON PRODUCING INC | Brine | 962 | 365 |
2007 | MASON PRODUCING INC | Brine | 793 | 365 |
2008 | MASON PRODUCING INC | Brine | 703 | 366 |
2009 | MASON PRODUCING INC | Brine | 739 | 365 |
2010 | MASON PRODUCING INC | Brine | 681 | 365 |
2011 | MASON PRODUCING INC | Brine | 644 | 365 |
2012 | MASON PRODUCING INC | Brine | 735 | 366 |
2013 | MASON PRODUCING INC | Brine | 878 | 365 |
2014 | MASON PRODUCING INC | Brine | 722 | 365 |
2015 | MASON PRODUCING INC | Brine | 613 | 365 |
2016 | MASON PRODUCING INC | Brine | 728 | 365 |
2017 | MASON PRODUCING INC | Brine | 747 | 365 |
2018 | MASON PRODUCING INC | Brine | 784 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1285466074 | 2011-10-12 0:00 | PW | No Violations | |
-1578868055 | 2015-2-2 0:00:0 | PW | No Violations | |
-172257800 | 2019-4-8 0:00:0 | PW | No Violations | 0.30 |
-2119503867 | 2016-1-27 0:00: | PW | No Violations | |
-578176801 | 2017-11-9 0:00: | PW | No Violations | 0.50 |
-987682310 | 2020-10-13 0:00 | PW | No Violations | 0.50 |
0000017988 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 5/19/94 INSPECTOR WILLIAM R. DUNFEE DATE 05/1919/94 DATA FROM OLD VAX INFO | |
0042376189 | 2002-09-12 | Production Wells | No Violations | During a check of wells in the area I discovered a leak on the bottom of the brine tank . It appears that the bottom has rusted thru and has been leaking only a short period . The leak has spread to an area of 12 to 15 feet by 2 to 4 feet wide. I also co |
0045176213 | 2002-10-07 | Production Wells | No Violations | The saltwater storage tank has been removed and another tank installed . Violation has been corrected . |
0172257800 | 2019-04-08 | Production Wells | No Violations | On the day of my inspection I found an 8 5/8-inch diameter casing, a 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of one 210 bbl. steel tank, one 50 bbl. steel tank, a horizontal separator. The tank is properly identified, and the production reporting is up to date. |
0578176801 | 2017-11-09 | Production Wells | No Violations | On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 2 3/8 inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of one 210 bbl. steel tank, one 50 bbl. steel tank, a production separator. The tank is properly identified, and the production reporting is up to date. |
1031016510 | 2019-11-15 0:00 | PW | No Violations | 0.30 |
1285466074 | 2011-10-12 | Production Wells | No Violations | This well is in production. No problems noted. |
1373367898 | 2013-07-08 | Production Wells | No Violations | This is a producing pump jack well. There were no problems noted at the time of the inspection. |
1483970032 | 2017-01-06 | Production Wells | No Violations | This is a producing pump jack well. There were no problems noted at the time of the inspection. The well was pumping at the time of the inspection. |
1558698484 | 2019-05-24 | Production Wells | No Violations | On the day of my inspection I found an 8 5/8-inch diameter casing, a 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of one 210 bbl. steel tank, one 50 bbl. steel tank, a production separator. The tank is properly identified, and the production reporting is up to date. |
1568806152 | 2019-9-18 0:00: | PW | No Violations | |
1578868055 | 2015-02-02 | Production Wells | No Violations | This is a producing pump jack well. There were no problems noted at the time of the inspection. |
1593519006 | 2020-6-30 0:00: | PW | No Violations | 0.30 |
17988 | PL | No Violations | ||
2119503867 | 2016-01-27 | Production Wells | No Violations | This is a producing pump jack well. There were no problems noted at the time of the inspection. |
42376189 | 2002-9-12 0:00: | PW | No Violations | 1.00 |
45176213 | 2002-10-7 0:00: | PW | No Violations | 0.70 |
For data sources see[9]