X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-075-25189

Well Details

Well ID: 34-075-25189
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Hardy Township
Operator Name: CAPSTONE OIL PRODUCING LLC
Well Pad ID:
Farm/Lease Name: SCHLABACH J Y
License Status: Producing
License Date: 1994-09-22
Spud Date: 1994-09-28
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 1994-10-26
Well Total Depth: 5980.00 ft
Configuration: Vertical
Latitude: 40.580000
Longitude: -81.900000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1994-09-22 Issued Date 9/22/94 Expired Date 9/22/95 Acres 0040000 Tool Type RTAF Proposed Formation CL/RR/TREMPELEAU Proposed Depth 05980 Proposed Drill Depth 05980
Original Spud 1994-09-28
Completed 1994-10-26
Reached Total Depth 1994-10-26
CO 1994-11-17 2772 HILL DRILLING INC GeoDate 9/22/94
Completion Report Received 1994-12-16
Construction Permit Expires 1995-09-22
Change of Owner 1997-06-24 Operator changed from 73, HOOVER FRANK W PRODUCER to 627, KENOIL
Change of Owner 2018-06-29 Operator changed from 627, KENOIL LLC to 9349, CAPSTONE OIL PRODUCING LLC
Record Last Modified 2018-06-29

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5814 5928 92
5816 5918 0
1997-06-29 5816 5918 0
5814 5928 92
5814 5928 92

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 3850 Gal 0 TREATED W/3850 GAL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1994 HILL DRILLING INC 6197.00 753.00 36
1995 HILL DRILLING INC 15908.00 920.00 365
1996 HILL DRILLING INC 15550.00 570.00 365
1997 KENOIL LLC 2090.00 139.00 365
1998 HOOVER FRANK W DBA CHEROKEE DR 3554.00 56.00 28
1999 KENOIL LLC 1602.00 172.00 0
2000 KENOIL LLC 2597.00 168.00 365
2001 KENOIL LLC 1646.00 124.00 365
2002 KENOIL LLC 1276.00 111.00 365
2003 KENOIL LLC 1222.00 86.00 365
2004 KENOIL LLC 1223.00 80.00 365
2005 KENOIL LLC 973.00 135.00 365
2006 KENOIL LLC 989.00 110.00 365
2007 KENOIL LLC 813.00 69.00 365
2008 KENOIL LLC 992.00 85.00 365
2009 KENOIL LLC 874.00 81.00 365
2010 KENOIL LLC 547.00 55.00 365
2011 KENOIL LLC 632.00 85.00 0
2012 KENOIL LLC 523.00 57.00 366
2013 KENOIL LLC 387.00 56.00 365
2014 KENOIL LLC 267.00 65.00 365
2015 KENOIL LLC 254.00 50.00 365
2016 KENOIL LLC 297.00 35.00 365
2017 KENOIL LLC 357.00 0.00 365
2018 KENOIL LLC 123.00 44.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1994 HILL DRILLING INC Brine 1175 36
1995 HILL DRILLING INC Brine 1005 365
1996 HILL DRILLING INC Brine 0 365
1997 KENOIL LLC Brine 117 365
1998 HOOVER FRANK W DBA CHEROKEE DR Brine 0 28
1999 KENOIL LLC Brine 58
2000 KENOIL LLC Brine 114 365
2001 KENOIL LLC Brine 52 365
2002 KENOIL LLC Brine 67 365
2003 KENOIL LLC Brine 26 365
2004 KENOIL LLC Brine 62 365
2005 KENOIL LLC Brine 39 365
2006 KENOIL LLC Brine 86 365
2007 KENOIL LLC Brine 92 365
2008 KENOIL LLC Brine 79 365
2009 KENOIL LLC Brine 49 365
2010 KENOIL LLC Brine 80 365
2011 KENOIL LLC Brine 80
2012 KENOIL LLC Brine 79 366
2013 KENOIL LLC Brine 56 365
2014 KENOIL LLC Brine 26 365
2015 KENOIL LLC Brine 67 365
2016 KENOIL LLC Brine 56 365
2017 KENOIL LLC Brine 12 365
2018 KENOIL LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1352308457 2016-6-17 0:00: PW No Violations
-1573036106 2012-8-17 0:00: PW No Violations
0206760079 2019-04-11 Production Wells No Violations On the day of my inspection I found an 8 5/8-inch diameter casing, a 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing, operated by a pumping unit with a gas motor. The production equipment is made up of one 210 bbl. steel tank, a horizontal separator, one 50 bbl. steel tank, and a rotary meter. The tank is properly identified, and production reporting is up to date. The dike area is shared with other wells
0670964089 2017-05-18 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
1352308457 2016-06-17 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
1512567051 2017-12-06 Production Wells No Violations On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 2 3/8 inch diameter tubing, operated by a pumping unit with a gas motor. I was unable to locate the production equipment.
1573036106 2012-08-17 Production Wells No Violations This well is in production and equipped with a pumping unit. I was unable to find the tanks. There were no problems noted at the time of the inspection.
1759979837 2015-08-03 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
1816766405 2019-8-2 0:00:0 PW No Violations 0.80
2005961262 2019-11-13 0:00 PW No Violations 0.30
206760079 2019-4-11 0:00: PW No Violations 0.50
670964089 2017-5-18 0:00: PW No Violations
991133082 2020-2-3 0:00:0 PW No Violations 0.30
iANGE00000 1997-08-05 Preliminary Restoration No Violations
iANGE000006 1997-8-5 0:00:0 PL No Violations

For data sources see[9]

References