34-075-25476

Well Details

Well ID: 34-075-25476
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Hardy Township
Operator Name: W H PATTEN DRILLING CO
Well Pad ID:
Farm/Lease Name: HASTINGS PAUL
License Status: Producing
License Date: 2006-11-17
Spud Date: 2007-09-04
Spud Drilling Contractor: MARIC DRILLING CO.
Final Drill Date: 2007-09-09
Well Total Depth: 3392.00 ft
Configuration: Vertical
Latitude: 40.590000
Longitude: -81.980000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-11-17 Proposed Formations:CLINTON, Issued Date:11/17/2006, Expired Date:11/17/2007 6:00:00 AM, Drilling unit acres:46.5, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-09-09
Reached Total Depth 2007-09-09
Completion Report Received 2007-10-29
Construction Permit Expires 2007-11-17
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-01-30 3202 3269 16
3202 3269 16
3202 3269 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2190 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 W H PATTEN DRILLING CO 504.00 239.00 89
2008 W H PATTEN DRILLING CO 2240.00 801.00 365
2009 W H PATTEN DRILLING CO 3706.00 1109.00 88
2010 W H PATTEN DRILLING CO 5120.00 850.00 365
2011 W H PATTEN DRILLING CO 5592.00 720.00 365
2012 W H PATTEN DRILLING CO 4634.00 640.00 366
2013 W H PATTEN DRILLING CO 5200.00 552.00 365
2014 W H PATTEN DRILLING CO 4711.00 390.00 365
2015 W H PATTEN DRILLING CO 5489.00 473.00 365
2016 W H PATTEN DRILLING CO 5091.00 385.00 365
2017 W H PATTEN DRILLING CO 4141.00 306.00 365
2018 W H PATTEN DRILLING CO 4557.00 304.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 W H PATTEN DRILLING CO Brine 80 89
2008 W H PATTEN DRILLING CO Brine 197 365
2009 W H PATTEN DRILLING CO Brine 165 88
2010 W H PATTEN DRILLING CO Brine 55 365
2011 W H PATTEN DRILLING CO Brine 35 365
2012 W H PATTEN DRILLING CO Brine 0 366
2013 W H PATTEN DRILLING CO Brine 25 365
2014 W H PATTEN DRILLING CO Brine 0 365
2015 W H PATTEN DRILLING CO Brine 0 365
2016 W H PATTEN DRILLING CO Brine 0 365
2017 W H PATTEN DRILLING CO Brine 0 365
2018 W H PATTEN DRILLING CO Brine 30 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1359480027 2018-11-2 0:00: PW No Violations 0.50
-1568811715 2011-8-22 0:00: PL No Violations
-1920064796 2013-2-7 0:00:0 PW No Violations
-2038612284 2016-12-9 0:00: PW No Violations
-226706035 2020-8-12 0:00: PW No Violations 1.00
-475381677 2014-9-15 0:00: PW No Violations
-748995003 2019-3-13 0:00: PW No Violations 0.50
0475381677 2014-09-15 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
0748995003 2019-03-13 Production Wells No Violations On the day of my inspection I found an 8 5/8-inch diameter casing, a 4 1/2-inch diameter casing, and 1 1/2-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of two 100 bbl. steel tanks, a 30-bbl. plastic tank, a vertical separator, and a recording gauge. The tanks are properly identified, and the production reporting is up to date.
0774566389 2017-11-08 Production Wells No Violations On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 1 1/2 inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of two 100 bbl. steel tanks, a 50 bbl. plastic tank, a vertical separator, and a recording gauge. The tanks are properly identified, and the production reporting is up to date.
1359480027 2018-11-02 Production Wells No Violations On the day of my inspection I found an 8 5/8-inch diameter casing, a 4 1/2-inch diameter casing, and 1 1/2-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of two 100 bbl. steel tanks, a 30-bbl. plastic tank, a vertical separator, and a recording gauge. The tanks are properly identified, and the production reporting is up to date.
1505924956 2020-1-31 0:00: PW No Violations 0.30
1568811715 2011-08-22 Preliminary Restoration No Violations Producing pump jack, no problems noted. PR passed.
1680564609 2019-9-19 0:00: PW No Violations
1874901675 2015-10-07 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
1920064796 2013-02-07 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
1921206859 2019-11-27 0:00 PW No Violations 0.30
2038612284 2016-12-09 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
325442741 2020-6-29 0:00: PW No Violations 0.50
774566389 2017-11-8 0:00: PW No Violations 0.50

For data sources see[9]

References