X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-075-25524

Well Details

Well ID: 34-075-25524
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Salt Creek Township
Operator Name: PONDEROSA CONSULTING SERVICES
Well Pad ID:
Farm/Lease Name: TROYER DANIEL J UNIT
License Status: Producing
License Date: 2007-12-18
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 40.640000
Longitude: -81.780000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-12-18 Proposed Formations:CLINTON, Issued Date:12/18/2007, Expired Date:12/17/2008 6:00:00 AM, Drilling unit acres:69.362, Proposed Well Type:OG, Proposed Well Class:POOL
Construction Permit Expires 2008-12-17
Record Last Modified 2013-10-23

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PONDEROSA CONSULTING SERVICES 4777.00 0.00 75
2009 PONDEROSA CONSULTING SERVICES 7747.00 0.00 365
2010 PONDEROSA CONSULTING SERVICES 5013.00 0.00 365
2011 PONDEROSA CONSULTING SERVICES 4366.00 0.00 365
2012 PONDEROSA CONSULTING SERVICES 2504.00 0.00 366
2013 PONDEROSA CONSULTING SERVICES 1204.00 0.00 365
2014 PONDEROSA CONSULTING SERVICES 909.00 0.00 365
2015 PONDEROSA CONSULTING SERVICES 216.00 0.00 365
2016 PONDEROSA CONSULTING SERVICES 3.00 0.00 365
2017 PONDEROSA CONSULTING SERVICES 0.00 0.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PONDEROSA CONSULTING SERVICES Brine 130 75
2009 PONDEROSA CONSULTING SERVICES Brine 61 365
2010 PONDEROSA CONSULTING SERVICES Brine 75 365
2011 PONDEROSA CONSULTING SERVICES Brine 0 365
2012 PONDEROSA CONSULTING SERVICES Brine 0 366
2013 PONDEROSA CONSULTING SERVICES Brine 0 365
2014 PONDEROSA CONSULTING SERVICES Brine 0 365
2015 PONDEROSA CONSULTING SERVICES Brine 0 365
2016 PONDEROSA CONSULTING SERVICES Brine 0 365
2017 PONDEROSA CONSULTING SERVICES Brine 0 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-15681900 2019-3-25 0:00: PW No Violations 1.50
-167117233 2019-8-21 0:00: PW No Violations
-1730968761 2018-8-8 0:00:0 PW No Violations 1.50
-1840349213 2020-1-16 0:00: PW No Violations 0.50
-295461453 2017-4-11 0:00: PW No Violations
-357795851 2012-3-12 0:00: PW No Violations
-930533092 2020-4-16 0:00: PW No Violations 1.00
0015681900 2019-03-25 Production Wells No Violations This is a follow up inspection of Compliance Notice 1730968761 issued on 8/19/2018. On the day of my inspection I found an 8 5/8-inch diameter casing, a 4 1/2-inch diameter casing, and 1 1/2-inch diameter tubing. The well is operated by a plunger lift system. The well was idle this day the tubing valve is in the closed position. The production equipment is made up of one 100 bbl. steel tank, one vertical separator. The tank is not properly identified.
0295461453 2017-04-11 Production Wells No Violations This is a producing plunger lift well. There were no problems noted at the time of the inspection.
0357795851 2012-03-12 Production Wells No Violations
1240083512 2020-9-14 0:00: PW No Violations 0.80
1559132749 2019-05-29 Production Wells No Violations This is a follow up inspection of Compliance Notice 1730968761 issued on 8/19/2018. On the day of my inspection I found an 8 5/8-inch diameter casing, a 4 1/2-inch diameter casing, and 1 1/2-inch diameter tubing. The well is operated by a plunger lift system. The well was idle this day the tubing valve is in the closed position. The production equipment is made up of one 100 bbl. steel tank, one vertical separator. The tank is not properly identified. 2018 production has not yet been reported. No new identification sign has been installed.
1730968761 2018-08-08 Production Wells Violations Noted On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 1 1/2 inch diameter tubing. The well is operated by a plunger lift system. The well was idle this day the valves are in the closed position. The production equipment is made up of one 100 bbl. steel tank, one vertical separator. The tank is not properly identified.
1955713707 2018-11-21 Production Wells No Violations On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 1 1/2 inch diameter tubing. The well is operated by a plunger lift system. The well was idle this day the valve is in the closed position. The production equipment is made up of one 100 bbl. steel tank, one vertical separator. The tank is not properly identified.
958524907 2019-11-12 0:00 PW No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1730968761 US-OH-117185 2018-08-13 Failure to legibly identify well

For data sources see[7]

References