Well ID: 34-077-20100 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.13,"lon":-82.58,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Huron | |
Municipality: Fairfield Township | |
Operator Name: STANDARD ENERGY CO | |
Well Pad ID: | |
Farm/Lease Name: VOGEL | |
License Status: Final Restoration | |
License Date: 2017-09-28 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 41.130000 | |
Longitude: -82.580000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-07-15 | 89 STANDARD ENERGY CO GeoDate 7/15/81 |
APP | 2017-09-28 | Proposed Formations:DELAWARE LIME, Issued Date:9/28/2017, Expired Date:9/28/2019 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2018-02-06 | STATUS CHANGE AS PER INSPECTION BY TOM BENKO 3/20/2003 PERMIT EXPIRED. |
Record Last Modified | 2018-07-11 | STATUS CHANGE AS PER INSPECTION BY TOM BENKO 3/20/2003 PERMIT EXPIRED. |
Construction Permit Expires | 2019-09-28 | STATUS CHANGE AS PER INSPECTION BY TOM BENKO 3/20/2003 PERMIT EXPIRED. |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2016 | STANDARD ENERGY CO | 0.00 | 0.00 | 0 |
2017 | STANDARD ENERGY CO | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2016 | STANDARD ENERGY CO | Brine | 0 | 0 |
2017 | STANDARD ENERGY CO | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1036094524 | 2017-10-24 0:00 | PW | No Violations | |
-1100029949 | 2019-1-31 0:00: | FR | No Violations | |
-1193700473 | 2018-2-5 0:00:0 | PB | No Violations | |
-171288228 | 2006-4-19 0:00: | PW | No Violations | |
-394398766 | 2003-1-14 0:00: | PW | No Violations | |
-803639042 | 2017-12-14 0:00 | PW | No Violations | |
0171288228 | 2006-04-19 | Production Wells | No Violations | Inspect well at request of SY. 10 inch caising with collar and 3 foot joint plate welded on top with 2 inch collar welded onto cover with fitting. Slight petroleum odor. Wet area adjacent to well appears to be old pit that was not properly closed. No ID. Incapable of production. Restoration of site was not completed properly. |
0394398766 | 2003-01-14 | Production Wells | No Violations | Well inspection. Well shut-in. Well incapable of production. No pipe run. No identification. |
0803639042 | 2017-12-14 | Production Wells | No Violations | Well currently has a plugging permit issued. Checked status of plugging activity. No plugging activity at the present time |
0926418979 | 2017-09-06 | Production Wells | No Violations | Spoke with operator about plugging of this well. Well currently has an open wellhead . Well is currently not capable of production and no change of status on well since last inspection. Operator is having his agent currently filling the application out to send to Central office for a plugging permit. |
1036094524 | 2017-10-24 | Production Wells | No Violations | Stopped at well area at the request of the plugging contractor to observe if the crops have been harvested yet. Found that the soybeans have been harvested and returned call to the plugging contractor. Plugging activities should be beginning in the near future. |
1100029949 | 2019-01-31 | Final Restoration | No Violations | Final restoration is not approved. Pit area still needs additional soil brought in. |
1193700473 | 2018-02-05 | Plug / Plug Back | No Violations | Service operator ran 1.5 inch tubng into well. Tubing was run to a depth of 642 feet deep and water level in wellbore is at a depth of approximately 300 from surface. |
1226965107 | 2019-04-05 | Final Restoration | No Violations | Received call from service operator that plugged well that final restoration has been completed. Old pit area still exists next to wellsite and will need to be leveled and filled before final restoration can be approved. |
1468601380 | 2016-06-09 | Production Wells | No Violations | Well consist of a 10 inch casing extending above ground level approximately 3 feet with welded reducer with 2 inch open hole. Identification is not posted at the present time and well is incapable of production in its present state. Area north of the well appears to be an old pit used for drilling purposes that have not been completed restored. Well appears to not have been in production lately. |
1515770653 | 2018-01-12 | Plug / Plug Back | No Violations | Surface rig is currently rigged up at well. Operator is planning on plugging well next week once the ground firms up and he is able to drive to well. |
1525966402 | 2018-05-09 | Final Restoration | No Violations | Inspected area around old wellsite for final restoration. Old pit is still very obvious and soil will need to be brought in from another source or additional grading will be needed. Contacted plugging contractor on need to fill in pit. Final restoration is not approved. |
1543864794 | 2018-12-03 | Final Restoration | No Violations | Final restoration is not approved. Site still needs to be leveled off and pit from the original drilling activities still need to be filled. Contacted plugging contractor on requirements. |
1567080376 | 2019-8-28 0:00: | FR | No Violations | |
1611764396 | 2018-02-06 | Plug / Plug Back | No Violations | Witnessed the installation of the 1 1/2 inch tubing to a depth of 642 feet deep. Class A cement was pumped through the tubing until cement was witnessed at the surface. Ten inch casing was cut off approximately 48 inches below the surface and steel plate with identification number of the well was installed. Area was backfilled and graded. |
926418979 | 2017-9-6 0:00:0 | PW | No Violations |
For data sources see[7]