X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-079-20261

Well Details

Well ID: 34-079-20261
Loading map...
Country: United States
State: Ohio
County: Jackson
Municipality: Bloomfield Township
Operator Name: SHERMAN STEVEN P & MICHELL D
Well Pad ID:
Farm/Lease Name: RAPIER
License Status: Domestic Well
License Date: 2012-07-24
Spud Date: 2008-04-24
Spud Drilling Contractor: HIGHLAND DRLG
Final Drill Date: 2008-04-29
Well Total Depth: 4701.00 ft
Configuration: Horizontal
Latitude: 38.990000
Longitude: -82.510000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-02-26 Proposed Formations:OHIO SHALE, Issued Date:2/26/2008, Expired Date:2/25/2009 6:00:00 AM, Drilling unit acres:54.7, Proposed Well Type:OG, Proposed Well Class:ESPW
Reached Total Depth 2008-04-29
Completion Report Received 2009-01-09
Correction to Well 2009-01-23 CORRECTION TO TARGET INFORMATION: NEW FOOTAGE= 750'SL & 1570'EL OF NE QTR., SEC. 17; NEW X= 1,994,395; NEW Y= 366,310; NEW TARGET ELEV= 830'. DECREASE UNIT SIZE TO 48.68 ACRES.
End of Confidential Data 2009-04-24
Change of Owner 2009-11-30 Operator changed from 8334, UNBRIDLED ENERGY OHIO LLC to 6295, KNOX ENERGY INC.
APP 2012-07-24 Proposed Formations:OHIO SHALE, Issued Date:7/24/2012, Expired Date:7/24/2014 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2013-02-13 Operator changed from 6295, KNOX ENERGY INC. to 9093, RAPIER DANIEL
Construction Permit Expires 2014-07-24
Change of Owner 2016-12-08 Operator changed from 9093, RAPIER DANIEL to 9813, SHERMAN STEVEN P & MICHELL D
Record Last Modified 2017-02-15

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 1001 Mscf 0 STAGE 6 OF 7
N2 0 1001 Mscf 0 STAGE 5 OF 7
N2 0 1000 Mscf 0 STAGE 7 OF 7
N2 0 1004 Mscf 0 STAGE 3 OF 7
N2 0 1002 Mscf 0 STAGE 4 OF 7
N2 0 1005 Mscf 0 STAGE 2 OF 7
N2 0 1002 Mscf 0 STAGE 1 OF 7

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 UNBRIDLED ENERGY OHIO LLC 0.00 0.00 0
2010 KNOX ENERGY INC. 0.00 0.00 0
2011 KNOX ENERGY INC. 0.00 0.00 0
2012 KNOX ENERGY INC. 0.00 0.00 0
2013 KNOX ENERGY INC. 0.00 0.00 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 UNBRIDLED ENERGY OHIO LLC Brine 0 0
2010 KNOX ENERGY INC. Brine 0 0
2011 KNOX ENERGY INC. Brine 0 0
2012 KNOX ENERGY INC. Brine 0 0
2013 KNOX ENERGY INC. Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1548938410 2009-2-17 0:00: PL No Violations
-1904054396 2009-5-20 0:00: PW No Violations
-215630671 2016-2-17 0:00: EX No Violations 3.00
-372030344 2008-4-24 0:00: DD No Violations
-919235668 2009-10-6 0:00: PL No Violations
0215630671 2016-02-17 Exempt Well Pre Transfer No Violations Pre exempt transfer inspection for domestic use well requested by Columbus. Upon arrival at the wells site I found a gas well that had no flow line connected to any of the casing heads. The seven inch casing head had one 2 fitting with a cap in it to shut it in. The other fitting in that casing head had a nipple with a valve that was in the open position. The 4 inch casing head had both fittings closed off by use of valves. The tubing had a valve, then a tee with one side plugged and the other side reduced down for a pressure gauge. There were no production lines coming off the well, even just a line for house gas. The well appeared to be in an idle state. The only ID at the well was a blank Knox energy sign. There was also about 18 joints of 2 laying on the ground by the well.
0372030344 2008-04-24 Drill / Deepen / Reopen No Violations Spud date 4-24-08. Equitable Drilling is overseeing the project. Highland Rig #5 is drilling the well. Rig is a Speed Star 185. BJ is cementing. Weatherford is Logging the hole. 120 9 5/8 conductor in a 12 3/8 hole. TD 1255 8 5/8 hole. 1220 7. Shoe at 1220. Baskets set at 120 & 240. Fire extinguisher at the entrance to the dog house. Had circulation and cement to surface. Cement fell back and was grouted from the surface. I was called out at 10pm on 4-24-08 for the surface job. It did not start until 4am due to logging problems and casing problems.
0919235668 2009-10-06 Preliminary Restoration No Violations Good id. Site is graded with good vegetative cover growing. A piece of plastic liner 15 by 5 that was lining the ditch from the well to the pit is still in place. I have called the company and they are working on removing the plastic liner. 18 joints of tubing are on the ground near the well. Well is equipped with tubing. No production equipment or lines are on location.
1132173375 2008-05-21 Drill / Deepen / Reopen No Violations They are flowing back the well now. The well made some oil during the beginning of flow back. Well is not making oil now. This well has been fraced. Pit is in good shape.
1269366676 2010-03-08 Administrative Inspection No Violations Received call from Bill Mitton. 3:20pm Re: will get identification on wells this week. They are exploring the possibility of a pipe line and heating two buildings.
1312897095 2011-07-14 Production Wells No Violations Good identification. Well is equipped with tubing. Well is not connected to production equipment or production lines. Good vegetative cover on location. I have talked to Bill Mitton and Barry Bowers about the well. They want to convert the well to a SWIW. Bill has asked to meet in the field to discuss the well and construction options.
1348759046 2012-09-24 Production Wells No Violations The well was shut-in, not producing gas. Well head was 25 from tank. There was no containment berm around tank. Sign barely legible. Property ownership change is in the process. New owner contacted me on 09.21.2012 about what he needed to transfer ownership from Knox to his company. Gave him information and had him contact Erica Freeman in Columbus about getting the latest forms for changing ownership of a well.
1403205604 2010-03-01 Administrative Inspection No Violations Called and talked to Terry Wade at 11:40am Re: Well needs identification. I also requested a written time line on getting the well in production or plugged. Terry said that they have not had a chance since taking over the wells to evaluate and see if it is capable or needs plugged. Terry told me that Bill Mitton is on vacation and will be back in a week. He will have Bill get in touch with me.
1420033453 2014-12-31 Administrative Inspection Violations Noted Faliure to pay $60 fee for 2014.

1509.50 Oil and gas regulatory cost recovery assessment. (2) The oil and gas regulatory cost recovery assessment for a well that becomes an exempt domestic well on and after June 30, 2010, shall be sixty dollars to be paid to the division of oil and gas resources management on the first day of July of each year. TOTAL AMOUNT OWED $60.00.

1548938410 2009-02-17 Preliminary Restoration No Violations No identification at wellhead. 2 inch tubing has been ran into the well. 18 joints of 2 inch tubing are stacked 5 feet from the wellhead. Pressure gauge on the 4.5 inch annulus reads 580 psi. The valve on the 2 inch tubing is closed. Both 2 inch valves on the 4.5 inch annulus are closed. Both 2 inch valves on the surface casing annulus are open. Pit has been closed. Grading at pit location is low and standing water is pooling in an area 75 feet by 30 feet by 8 inches deep. Pictures were taken. No seed or mulch has been applied to pit site. Well site is gravel.
1904054396 2009-05-20 Production Wells No Violations Good identification. Emergency contact # 724-934-2340. Steve (Huffman-Bowers ) is grading the site now. No production equipment or lines on location. 18 joints of 2 tubing are on the ground by the well.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1420033453 US-OH-112283 2015-01-16 $60 cost recovery fee not paid for 2014

For data sources see[8]

References