If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-081-20367 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.53,"lon":-80.81,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Jefferson | |
Municipality: Ross Township | |
Operator Name: BEUCLER BROTHERS INC | |
Well Pad ID: | |
Farm/Lease Name: WADE ERNEST H | |
License Status: Producing | |
License Date: 1966-09-15 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: 1966-09-18 | |
Well Total Depth: 950.00 ft | |
Configuration: Vertical | |
Latitude: 40.530000 | |
Longitude: -80.810000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Completed | 1966-09-18 | GL=811.21 NSR 11/3/1966 COMPL. 11/3/1966 |
Reached Total Depth | 1966-09-18 | GL=811.21 NSR 11/3/1966 COMPL. 11/3/1966 |
CO | 1993-05-11 | 2806 BEUCLER LOUIS J GeoDate |
CO | 1993-05-11 | 4321 TWADDLE ARNOLD |
CO | 1994-07-13 | 4834 BEUCLER BROTHERS INC GeoDate |
Record Last Modified | 2013-10-03 | GL=811.21 NSR 11/3/1966 COMPL. 11/3/1966 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 913 | 919 | 2 |
913 | 919 | 2 | |
913 | 919 | 2 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | BEUCLER BROTHERS INC | 0.00 | 38.00 | 0 |
2012 | BEUCLER BROTHERS INC | 0.00 | 0.00 | 80 |
2013 | BEUCLER BROTHERS INC | 0.00 | 30.00 | 80 |
2014 | BEUCLER BROTHERS INC | 0.00 | 10.00 | 80 |
2015 | BEUCLER BROTHERS INC | 0.00 | 0.00 | 80 |
2016 | BEUCLER BROTHERS INC | 0.00 | 34.00 | 80 |
2017 | BEUCLER BROTHERS INC | 0.00 | 0.00 | 80 |
2018 | BEUCLER BROTHERS INC | 0.00 | 0.00 | 80 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | BEUCLER BROTHERS INC | Brine | 0 | 0 |
2012 | BEUCLER BROTHERS INC | Brine | 60 | 80 |
2013 | BEUCLER BROTHERS INC | Brine | 112 | 80 |
2014 | BEUCLER BROTHERS INC | Brine | 112 | 80 |
2015 | BEUCLER BROTHERS INC | Brine | 75 | 80 |
2016 | BEUCLER BROTHERS INC | Brine | 0 | 80 |
2017 | BEUCLER BROTHERS INC | Brine | 27 | 80 |
2018 | BEUCLER BROTHERS INC | Brine | 27 | 80 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1019795007 | 2015-3-23 0:00: | PW | No Violations | 1.00 |
-108017393 | 2013-9-27 0:00: | PW | No Violations | 2.00 |
-123457158 | 2013-5-16 0:00: | AM | No Violations | 1.00 |
-1763738081 | 2013-5-30 0:00: | PW | No Violations | 2.50 |
-440573754 | 2016-8-9 0:00:0 | PW | No Violations | 1.00 |
0108017393 | 2013-09-27 | Production Wells | No Violations | I was on location to close out a compliance notice issues to this well. A dike has been erected around the tank battery, production statements have been filed and the well has stopped continual flaring of natural gas with the use of pop off valve that has been installed while the wells are not currently being produced. |
0123457158 | 2013-05-16 | Administrative Inspection | No Violations | I was on the phone with Mr. William Beucler regarding 2 compliance notices that I issued for the Wade lease. He is in the process of installing SPCC dikes on the tank battery for the 2 wells and wanted to know how to properly vent the gas from the well because there is no way to sell the gas commercially. I told him that he could flair the gas or use a mechanical pressure vent valve to control the gas venting. I will make a status check on the wells to determine when they are brought into compliance. |
0440573754 | 2016-08-09 | Production Wells | No Violations | On the date of my inspection I found the tank battery to include two properly identified shared 100 barrel tanks, a vertical separator within a partial earthen dike, and a 1 inch poly line attached to a tree uphill from the battery venting gas. The well is equipped with a pumping unit, rods, 2.375 inch tubing and 4.5 inch casing. The tubing valve is in the open position and casing valve is in the closed position. Production records are current through 2015, however production does not meet the minimum. The well appears capable of producing and is connected to electric. |
0996108875 | 2017-06-27 | Production Wells | No Violations | On the date of my inspection I found the tank battery to include two properly identified shared 100 barrel tanks, a vertical separator within a partial earthen dike, and a 1 inch poly line running from the separator to a tree uphill from the tanks venting gas. The well is equipped with a pumping unit, rods, 2.375 inch tubing, and 4.5 inch casing. The tubing and 4.5 inch casing are tied together by a 2.375 inch production line. The tubing valve is in the open position and casing valve is in the closed position. A pressure gauge on the production line reads 0 pounds per square inch. Production records are current. The drain valve on the bottom of the eastern 100 barrel tank is leaking. There is an area approximately 30 feet long by 15 feet wide on the south side of the eastern most 100 barrel tank that is heavily stained and void of vegetation. Salt crystals can be seen on the ground and there is evidence of animals digging in the area. There is a culvert that drains this area. The culvert crosses the road and drains directly into Yellow Creek. I will contact Beucler Brothers Inc about the stained area. |
1019795007 | 2015-03-23 | Production Wells | No Violations | On the date of inspection I found production equipment to include two community 100bbl tanks, a vertical separator within a partial earthen dike, and a 1 inch poly line that has been run into the woods on the hill above the tank battery attached to a tree venting gas. The well is equipped with a pumping unit, rods, 2.375 inch tubing, 4.5 inch casing, and 8.625 inch casing. At the time of my inspection the tubing valve and casing valve are in open position. Production records are current through 2013. |
1367519258 | 2013-05-02 | Production Wells | Violations Noted | There are 2 pumpjack style wells producing into a single tank battery. The tank battery consists of 2 production tanks and a mechanical separator. The tank battery has no SPCC dike of any kind and is located near a creek drainage. Annual production for this well has never been filed. Coming off of the separator is a plotline that is run into the woods, tied up a tree and is constantly and illegally venting gas. These issues need to be addressed before the well can be brought into compliance. |
1481550545 | 2016-12-12 | Production Wells | No Violations | On the date of my inspection I found the tank battery to include two properly identified shared 100 barrel tanks, a vertical separator within a partial earthen dike, and a 1 inch poly line attached to a tree uphill from the battery venting gas. The well is equipped with a pumping unit, rods, 2.375 inch tubing, and 4.5 inch casing. The tubing and 4.5 inch casing are tied together by a 2.375 inch production line. The tubing valve is in the open position and casing valve is in the closed position. A pressure gauge on the production line reads 0 pounds per square inch. Production records are current through 2015, however production does not meet the minimum. |
1572457647 | 2019-10-30 0:00 | PW | No Violations | 1.00 |
1763738081 | 2013-05-30 | Production Wells | No Violations | I was onsite to follow up on a compliance notice issued for this well. The tank battery for these 2 wells have had a dike installed around it. The production for the well has also been submitted, Currently the well is still venting gas. I was in contact with the well owner and he is still unsure if he wanted to flare the wells or not. He is evaluating his options currently. I will pass the well for compliance when the venting issue has been taken care of. |
2111100441 | 2012-10-03 | Production Wells | No Violations | My inspection found a pump jack well with a 100 barrel production tank and a vertical mechanical separator. The tank and separator do not have a dike surrounding them, but talked with the well pumper and well is currently not producing until new gas lines, brine tank and dike is installed. Gas from the well is flared on hillside when in production. Will follow up on the site to ensure well is brought into compliance. |
996108875 | 2017-6-27 0:00: | PW | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1367519258 | US-OH-110773 | 2013-10-09 | No SPCC dike/or failure to keep dike free of water or oil | |
1367519258 | US-OH-110774 | 2013-10-09 | Unlawful venting or flaring of gas | |
1367519258 | US-OH-110775 | 2013-10-09 | Statement of annual production not filed |
For data sources see[8]