34-081-20557

Well Details

Well ID: 34-081-20557
Loading map...
Country: United States
State: Ohio
County: Jefferson
Municipality: Ross Township
Operator Name: EAP OHIO LLC
Well Pad ID: US-OH-001072
Farm/Lease Name: R KIRK 32-11-3
License Status: Producing
License Date: 2020-01-09
Spud Date: 2015-05-09
Spud Drilling Contractor:
Final Drill Date: 2020-03-05
Well Total Depth: 23321.00 ft
Configuration:
Latitude: 40.480000
Longitude: -80.860000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-06-26 Proposed Formations:TRENTON-BLACK RIVER, Issued Date:6/26/2014, Expired Date:6/25/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2016-06-27 Proposed Formations:TRENTON THRU BLACK RIVER, Issued Date:6/27/2016, Expired Date:6/27/2018 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2018-08-21 Proposed Formations:POINT PLEASANT, Issued Date:8/21/2018, Expired Date:8/20/2020 12:00:00 PM, Drilling unit acres:765, Proposed Well Type:OG, Proposed Well Class:POOL
Record Last Modified 2018-10-02 Not completed or finished drilling. From inspection reports : inspection today found the access road gate locked and the access road in good repair. The pad is fenced and all man doors locked. I found the #8 partially drilled with only 30 inch conductor in place, ascertained from the previous MRI Inspection Report for this well dated 5/10/2015. Tubular gates and concrete barriers were in place around the cellar.
Construction Permit Expires 2020-08-20 Not completed or finished drilling. From inspection reports : inspection today found the access road gate locked and the access road in good repair. The pad is fenced and all man doors locked. I found the #8 partially drilled with only 30 inch conductor in place, ascertained from the previous MRI Inspection Report for this well dated 5/10/2015. Tubular gates and concrete barriers were in place around the cellar.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
8926 23175 0
8926 23175 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1495334587 2020-4-16 0:00: CT No Violations 1.50
-1688987001 2020-2-23 0:00: CS No Violations 4.00
-2128735504 2020-4-2 0:00:0 CT No Violations 1.50
-234660882 2020-5-14 0:00: CT No Violations 1.00
-40330313 2015-5-10 0:00: CS No Violations 4.50
0040330313 2015-05-10 Casing String Witnessed No Violations On the date of inspection I am on site to witness the cementing of the conductor pipe. I was informed by Chesapeake consultant Brett Farnsworth that Rocky Mountain Drilling had spudded on 5-9-15 and drilled a 36 inch diameter hole to a depth of 120 feet. Chesapeake has elected to set a 30 inch diameter, 140lbs/ft, 29.25 inch ID rather than the 26 inch conductor that was permitted in anticipation of a mine string. The 30 inch conductor was set on bottom. I field titrated mix/displacement water with a Quantab and found chlorides to be at a level of 56ppm. Express Energy Services pumped 330sk of Class A cement, 15.6ppg, 1.2 yield, 2% CaCl2, and 0.50lbs.sk of cello flake. Express displaced cement with 91bbl of fresh water. 30bbl of cement returned to surface and stayed at surface while I was on site.
0485350716 2018-03-22 Drill / Deepen / Reopen No Violations On the day of my inspection I found this pad to contain one properly labeled producing well and one unlabled conductor casing, which is this permit. Cannot do a preliminary restoration on this permit as it has not been drilled to total depth. Permit 585 is in production and a preliminary restoration was completed for that permit.
0893346072 2016-03-10 Drill / Deepen / Reopen No Violations My inspection today found the access road gate locked and the access road in good repair. The pad is fenced and all man doors locked. I found the #8 partially drilled with only 30 inch conductor in place, ascertained from the previous MRI Inspection Report for this well dated 5/10/2015. Tubular gates and concrete barriers were in place around the cellar. Well identification number for this well was not found on the well nor on signage at entrance to access road. The equipment on the pad consists of the following:

2 400 bbl. production tanks contained in a metal dike. 1 Shut-in well. 1 well with conductor in place. 1 Upright Sand Separator. 1 GPU.

1110409073 2020-4-23 0:00: CT No Violations 1.50
1513210795 2020-1-31 0:00: DD No Violations 1.00
18032470 2020-4-8 0:00:0 CT No Violations 1.50
1805088569 2020-5-6 0:00:0 CT No Violations 1.00
485350716 2018-3-22 0:00: DD No Violations 1.00
861764185 2020-6-24 0:00: PL No Violations 1.00
893346072 2016-3-10 0:00: DD No Violations 1.00

For data sources see[4]