Well ID: 34-081-20699 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.22,"lon":-80.85,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Jefferson | |
Municipality: Smithfield Township | |
Operator Name: ASCENT RESOURCES UTICA LLC | |
Well Pad ID: US-OH-001458 | |
Farm/Lease Name: CLUB NW SMF JF | |
License Status: Producing | |
License Date: 2017-03-31 | |
Spud Date: 2017-03-03 | |
Spud Drilling Contractor: | |
Final Drill Date: 2017-08-05 | |
Well Total Depth: 19590.00 ft | |
Configuration: Horizontal | |
Latitude: 40.220000 | |
Longitude: -80.850000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2017-01-24 | Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:1/24/2017, Expired Date:1/24/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
APP | 2017-03-31 | Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:3/31/2017, Expired Date:3/31/2019 12:00:00 PM, Drilling unit acres:375.55, Proposed Well Type:OG, Proposed Well Class:EOUT |
Correction to Well | 2017-05-19 | as drilled plat recvd TE |
Reached Total Depth | 2017-08-05 | |
Correction to Well | 2017-10-06 | CORRECTION TO UNIT SIZE, TARGET INFORMATION AND ADDED "NO PERF ZONE" TO SPECIAL PERMIT CONDITIONS. |
Completion Report Received | 2018-03-15 | |
Record Last Modified | 2018-03-28 | |
Correction to Well | 2018-03-30 | UPDATE ACREAGE.TAKE/TARGET PER AS-DRILLED PLAT |
Construction Permit Expires | 2019-03-31 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2018-03-20 | 9683 | 9823 | 30 |
2018-03-20 | 19304 | 19408 | 18 |
19304 | 19408 | 18 | |
9683 | 9823 | 30 | |
9683 | 9823 | 30 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 09/27/2017 | 10/25/2017 | 9325 | 16,187,600.0 | 0 |
2 | Sep 27 2017 12:02AM | Oct 25 2017 2:31AM | 9,325 | 16,187,583 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | HAI-OS ACID INHIBITOR | Halliburton | Corrosion Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 |
FE-1A ACIDIZING COMPOSITION | Halliburton | Additive | Listed Below | Listed Below | 0 | 0 | 0 | |
MC S-2510T | Halliburton | Scale Inhibitor | Listed Below | |||||
Ingredients | Listed Above | Listed Above | ||||||
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
MC B-8614 | Halliburton | Biocide | Listed Below | Listed Below | 0 | 0 | 0 | |
SAND-PREMIUM WHITE-40/70, BULK | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
HYDROCHLORIC ACID | Halliburton | Solvent | Listed Below | Listed Below | 0 | 0 | 0 | |
WG-36 GELLING AGENT | Halliburton | Gelling Agent | Listed Below | Listed Below | 0 | 0 | 0 | |
FR-76 | Halliburton | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
MC MX 2-2822 | Halliburton | Scale Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
HYDROCHLORI C ACID | Halliburton | Solvent | Listed Below | |||||
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) | Halliburton | Proppant | Inorganic salt | Proprietary | 30 | 0.01996 | ||
Methanol | 67-56-1 | 60 | 0.00708 | |||||
Glutaraldehyde | 111-30-8 | 30 | 0.00642 | |||||
Sodium persulfate | 7775-27-1 | 100 | 0.00009 | |||||
Crystalline silica, quartz | 14808-60-7 | 100 | 12.42567 | |||||
Ethanol | 64-17-5 | 1 | 0.00021 | |||||
Acrylamide acrylate copolymer | Proprietary | 30 | 0.01996 | |||||
Phosphoric acid | 7664-38-2 | 0.1 | 0.00002 | |||||
Neutralized Polyacrylic Emulsion | Proprietary | 10 | 0.00232 | |||||
Sodium sulfate | 7757-82-6 | 0.1 | 0 | |||||
Quaternary ammonium compounds,
benzyl-C12- 16-alkyldimethyl chlorides |
68424-85-1 | 5 | 0.00107 | |||||
Ethoxylated alcohols | Proprietary | 30 | 0.00024 | |||||
Acetic acid | 64-19-7 | 60 | 0.00289 | |||||
FR-76 | Halliburton | Friction Reducer | Listed Below | |||||
MC MX 2-2822 | Halliburton | Scale Inhibitor | Listed Below | |||||
MC S-2510T | Halliburton | Scale Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
Ingredients | Listed Above | Listed Above | Water | 7732-18-5 | 100 | 1.14591 | 1,788,880.0 | |
Water | 7732-18-5 | 100 | 1.14591 | |||||
FE-1A ACIDIZING COMPOSITION | Halliburton | Additive | Listed Below | |||||
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl chlorides |
68424-85-1 | 5 | 0.00107006 | 1671 | ||||
Formaldehyde | 50-00-0 | 0.09 | 0.00001973 | 31 | ||||
Crystalline silica, quartz | 14808-60-7 | 100 | 12.4257 | 19,397,700.0 | ||||
Sodium persulfate | 7775-27-1 | 100 | 0.00009480 | 148 | ||||
Olefins | Proprietary | 5 | 0.00009569 | 152 | ||||
Acrylamide acrylate copolymer | Proprietary | 30 | 0.019957 | 31155 | ||||
Inorganic salt | Proprietary | 30 | 0.019957 | 31155 | ||||
Modified thiourea polymer | Proprietary | 30 | 0.000239231 | 374 | ||||
Hydrochloric acid | 7647-01-0 | 7.5 | 0.07929 | 123775 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.019957 | 31155 | ||||
Acetic acid | 64-19-7 | 60 | 0.00289273 | 4516 | ||||
Sodium sulfate | 7757-82-6 | 0.1 | 0.00000009 | 1 | ||||
Acetic anhydride | 108-24-7 | 100 | 0.00482121 | 7527 | ||||
Guar gum | 9000-30-0 | 100 | 0.00257728 | 4024 | ||||
Fatty acids, tall oil | Proprietary | 30 | 0.000239231 | 374 | ||||
Neutralized Polyacrylic Emulsion | Proprietary | 10 | 0.00231752 | 3618 | ||||
Methanol | 67-56-1 | 60 | 0.00708389 | 11059 | ||||
Phosphoric acid | 7664-38-2 | 0.1 | 0.00002140 | 34 | ||||
Ethanol | 64-17-5 | 1 | 0.000214011 | 335 | ||||
Ethylene Glycol | 107-21-1 | 60 | 0.0139051 | 21708 | ||||
Glutaraldehyde | 111-30-8 | 30 | 0.00642033 | 10023 | ||||
Ethoxylated alcohols | Proprietary | 30 | 0.000239231 | 374 | ||||
Amines, polyethylenepoly-, ethoxylated,
phosphonomethylated, sodium salts |
70900-16-2 | 30 | 0.00657546 | 10265 | ||||
Sodium chloride | 7647-14-5 | 5 | 0.00109591 | 1711 | ||||
Propargyl alcohol | 107-19-7 | 10 | 0.00007974 | 125 | ||||
Fresh Water | Operator | Base Fluid | Water | 7732-18-5 | 100 | 86.3762 | 134,842,000.0 | |
WG-36 GELLING AGENT | Halliburton | Gelling Agent | Acetic acid | 64-19-7 | 60 | 0.00289 | ||
Ethanol | 64-17-5 | 1 | 0.00021 | |||||
Methanol | 67-56-1 | 60 | 0.00708 | |||||
Sodium sulfate | 7757-82-6 | 0.1 | 0 | |||||
Neutralized Polyacrylic Emulsion | Proprietary | 10 | 0.00232 | |||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.01996 | |||||
Inorganic salt | Proprietary | 30 | 0.01996 | |||||
Sodium persulfate | 7775-27-1 | 100 | 0.00009 | |||||
Phosphoric acid | 7664-38-2 | 0.1 | 0.00002 | |||||
Crystalline silica, quartz | 14808-60-7 | 100 | 12.42567 | |||||
Quaternary ammonium compounds,
benzyl-C12- 16-alkyldimethyl chlorides |
68424-85-1 | 5 | 0.00107 | |||||
Glutaraldehyde | 111-30-8 | 30 | 0.00642 | |||||
Modified thiourea polymer | Proprietary | 30 | 0.00024 | |||||
SP BREAKER | Halliburton | Breaker | ||||||
HAI-OS ACID INHIBITOR | Halliburton | Corrosion Inhibitor | Listed Below | |||||
SP BREAKER | Halliburton | Breaker | Listed Below | |||||
Listed Below | Listed Below | 0 | 0 | 0 | ||||
2 | MC B-8614 | Halliburton | Biocide | Listed Below | ||||
FR-76 | Halliburton | Friction Reducer | Listed Below | |||||
MC MX 2-2822 | Halliburton | Scale Inhibitor | Listed Below | |||||
HYDROCHLORI C ACID | Halliburton | Solvent | Listed Below | |||||
SAND- PREMIUM WHITE-40/70, BULK | Halliburton | Proppant | Listed Below | |||||
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) | Halliburton | Proppant | Olefins | Proprietary | 5 | 0.0001 | ||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.01996 | |||||
Acetic anhydride | 108-24-7 | 100 | 0.00482 | |||||
Guar gum | 9000-30-0 | 100 | 0.00258 | |||||
Ethylene Glycol | 107-21-1 | 60 | 0.01391 | |||||
Modified thiourea polymer | Proprietary | 30 | 0.00024 | |||||
Formaldehyde | 50-00-0 | 0.09 | 0.00002 | |||||
Sodium chloride | 7647-14-5 | 5 | 0.0011 | |||||
Listed Below | ||||||||
Amines, polyethylenepoly-, ethoxylated,
phosphonomethylated, sodium salts |
70900-16-2 | 30 | 0.00658 | |||||
Fatty acids, tall oil | Proprietary | 30 | 0.00024 | |||||
Hydrochloric acid | 7647-01-0 | 7.5 | 0.07929 | |||||
Propargyl alcohol | 107-19-7 | 10 | 0.00008 | |||||
WG-36 GELLING AGENT | Halliburton | Gelling Agent | Formaldehyde | 50-00-0 | 0.09 | 0.00002 | ||
Guar gum | 9000-30-0 | 100 | 0.00258 | |||||
Acrylamide acrylate copolymer | Proprietary | 30 | 0.01996 | |||||
Sodium chloride | 7647-14-5 | 5 | 0.0011 | |||||
Hydrochloric acid | 7647-01-0 | 7.5 | 0.07929 | |||||
Fatty acids, tall oil | Proprietary | 30 | 0.00024 | |||||
Ethylene Glycol | 107-21-1 | 60 | 0.01391 | |||||
Listed Below | ||||||||
Amines, polyethylenepoly-, ethoxylated,
phosphonomethylated, sodium salts |
70900-16-2 | 30 | 0.00658 | |||||
Ethoxylated alcohols | Proprietary | 30 | 0.00024 | |||||
Olefins | Proprietary | 5 | 0.0001 | |||||
Acetic anhydride | 108-24-7 | 100 | 0.00482 | |||||
Propargyl alcohol | 107-19-7 | 10 | 0.00008 | |||||
SP BREAKER | Halliburton | Breaker | Listed Below | |||||
Fresh Water | Operator | Base Fluid | Water | 7732-18-5 | 100 | 86.37623 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2017-10-25 | H2O | 8 | 286601 Gal | 350137 | Halliburton | STAGE 56/56
STAGES 2-55 SEE IMAGES |
2017-09-27 | H2O | 8 | 283083 Gal | 346577 | Halliburton | STAGE 1/56
STAGES 2-55 SEE IMAGES |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | ASCENT RESOURCES UTICA LLC | 271756 | 0 | 13 |
2018 | ASCENT RESOURCES UTICA LLC | 5998605 | 0 | 365 |
2019 | ASCENT RESOURCES UTICA LLC | 584911 | 0 | 81 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | ASCENT RESOURCES UTICA LLC | Brine | 3185 | 13 |
2018 | ASCENT RESOURCES UTICA LLC | Brine | 29259 | 365 |
2019 | ASCENT RESOURCES UTICA LLC | Brine | 2971 | 81 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-110948385 | 2020-4-20 0:00: | PW | No Violations | 1.00 |
-1396636321 | 2017-3-3 0:00:0 | CS | No Violations | 3.00 |
-1571747739 | 2017-8-16 0:00: | CT | No Violations | 0.70 |
-189695645 | 2017-10-2 0:00: | CT | No Violations | 2.00 |
-558708424 | 2017-12-11 0:00 | CT | No Violations | 0.50 |
-565650139 | 2017-3-23 0:00: | CS | No Violations | 8.00 |
-673478582 | 2018-4-16 0:00: | PL | No Violations | 1.00 |
0189695645 | 2017-10-02 | Completion Testing | No Violations | On the date of my inspection I found a Halliburton crew rigged up on all three wells on the pad for hydraulic fracturing operations. While I was on site I witnessed Halliburton pump the frac job for stage 11 of 56 for this well and stage 25 of 70 for permit 34-081-2-0700. Halliburton has stimulated stage 11 of 56 states on this well. During the frac, Halliburton pumped approximately 347000 pounds of sand using 6605 barrels of water. They were able to achieve pumping rates of 80 barrels per minute during the job. During the final flush of the stage, the perfs screened out and they were unable to complete the stage. Ascent had Halliburton flow back 600 barrels from the well in an attempt to re-establish flow down hole. All hazardous materials are within double containment which is in good condition, free of visible punctures or tears. The location is surrounded by a fenced berm with healthy vegetation. The pad drain valves show they are in the closed position. |
0409693023 | 2017-10-30 | Completion Testing | No Violations | On the date of my inspection I found the pad being prepared for drill out operations. The frac crew has moved off the pad after completing 56 stages on this well. Ascent estimates the drill out rig will be moving onto the pad within 8 days. Pressure gauges on the surface and intermediate casings read 0 and 900 pounds per square inch respectively. The pad is surrounded by a fenced earthen dike covered by healthy vegetation. The pad drain valves are in the closed position and do not appear to be leaking. |
0471606471 | 2017-08-03 | Drill / Deepen / Reopen | No Violations | On the date of my inspection I found Patterson drilling rig 284 running the production casing at 10100 feet towards their total depth of 19590 feet. The Ascent company man expects to finish running casing this evening and begin cementing before morning on 8/3/17. The pad is surrounded by a fenced earthen dike covered by healthy vegetation. The pad drain valves are in the closed position. The eastern drain that had been leaking has had a screw in plug placed in the end to stop water from leaking out. The pad outlet pipe has some algae growth inside the pipe. The company man called the company indicated that he would try to call about having the valve fixed. |
0558708424 | 2017-12-11 | Completion Testing | No Violations | On the date of my inspection I found a well maintained access road with an unlocked gate. The pad is surrounded by a fenced earthen dike covered by healthy vegetation. The pad has 5 recently stimulated wells, 10 sand separators, 5 gas production units, and 2 shared 500 barrel tanks within a metal dike. Identification has not been placed on the wellheads yet. The wellheads are equipped with christmas tree valves. There are 2 flowlines coming from each wellhead. Currently Express Energy Services and ROC Service Company are onsite rigging up flowback equipment on the 5H, 7H, and 8H. Ascent anticipates flowback operation to begin on 12/12/17. |
0565650139 | 2017-03-23 | Casing String Witnessed | No Violations | The purpose of my inspection was to witness the second hydrostatic pressure test on the 24 conductor/mine string. The initial test failed due to what was believed to be a bad cement job. Prior to arriving on location I spoke via telephone with Company Representative Eugene Lanham. Mr. Lanham stated that O-Tex Pumping LLC arrived the previous night and cemented the borehole with 350 sks of Class H cement mixed at 15.6 ppg. The cement was pumped from surface through one joint of drill pipe. I witnessed Falcon 26 pick up the 17.5 bit and drilling assembly and tag the top of cement at 63 KB. The cement was drilled out of the casing utilizing fresh water. This section of well was drilled to a new total measured depth of 158.5 KB (previous TD was 154 KB) to confirm a geologic formation was not the cause of the previous test failure. I was present at the flowline and witnessed formation returns prior to giving approval to perform the hydrostatic pressure test. After reaching TD, the hole was circulated clean and loaded with freshwater. I observed the static water level at surface for 30 minutes. The water level did not fall. I communicated to Mr. Lanham that the test had passed and operations could proceed. |
0673478582 | 2018-04-16 | Preliminary Restoration | No Violations | On the day of my inspection I found this pad containing 5 properly labeled wells that are producing. This well is equipped with christmas tree style wellhead. Pressure gauges read as follows: Surface 5 psi, Intermediate 667 psi, Production gauge was covered, and tubing was 1600 psi. Production equipment includes two 500 barrel steel tanks within their own steel containment, five line heaters, and five GPUs. Site is stable and vegetated. Site meets preliminary restoration requirements of 1509.072A. |
0744795100 | 2017-03-22 | Casing String Witnessed | No Violations | The purpose of my inspection was to witness the hydrostatic pressure test on well #2-0699. Falcon 26 drilled the 24 casing shoe out with a 17.5 to a total depth of 155 KB. At 11:42 a 120 bbl vacuum water truck began to load the open hole and casing from surface by gravity. The truck ran out of water and moved over to reload with water. Calculated total volume of the open hole and casing was 73 bbl. Company Representative Eugene Lanham lowered a plastic bottle on a string to tag the water level. The water level was tagged at 72 measured from the top of the casing converter. The truck loaded an additional volume of water down the casing. Mr. Lanham tagged the water level again at 72 at 13:45. After waiting 15 minutes, the water level was tagged again and measured at 78 feet. The hydrostatic test failed. A review of the drillers log indicated the conductor rig encountered shale and coal formations from 60-90. After discussion, the determination was made to attempt a remedial cement job by balance method followed by a second hydrostatic pressure test. I will return to location to witness the second hydrostatic pressure test. |
1396636321 | 2017-03-03 | Casing String Witnessed | No Violations | I am on site today to witness the cementing of 24 inch conductor casing. Precision Drilling drilled a 30 inch diameter hole to a depth of 125 feet and ran 125 feet of 24 inch diameter 96 pound per foot conductor casing. A 10 foot mine void was found from 70 to 80 feet, a basket was ran at 55 feet. Allied pumped 94 sacks of class A cement, 1.2 yield, 15.6 pounds per gallon with 2 percent Calcium Chloride and 0.75 pound per sack flow seal to set the shoe, leaving 10 feet of cement in the conductor. Gravel, bariseal, and calcium chloride were added down the backside of the 24 inch conductor to set the basket. Allied pumped 30 barrels of cement down the backside until cement remained approximately 8 feet below the cellar floor. Ascent will have the cellar topped out with ready mix. |
1490429619 | 2017-03-25 | Casing String Witnessed | No Violations | I am on site to witness the running and cementing of 13.375 inch surface casing. Falcon Rig 26 drilled a 17.5 inch diameter hole to a depth of 1440 feet and set 1425 feet of 13.375 inch 61 pound per foot casing. O-Tex established circulation with fresh water, pumped 1420 sacks of class H cement, 1.2 yield and 15.6 pound per gallon, 2 percent calcium chloride, 0.25 pound cello flake per sack. Approximately 50 barrels of cement returned to surface. Due to vacuum truck complications during displacement, O-Tex had to stop pumping for approximately 12 minutes. When pumping resumed, the cement would not pump down. Approximately 322 feet of cement was left in the casing, including the shoe track. The cement head was shut in and left attached for the cement to set up. |
1501161472 | 2017-07-27 | Drill / Deepen / Reopen | No Violations | On the date of my inspection I found Patterson drilling rig 284 drilling their production string at approximately 11500 feet. The pad is surrounded by a fenced earthen dike covered by healthy vegetation. Most of the containment on the pad is full of water. The Ascent company man indicated that he has been trying to get vacuum trucks to the site to remove the water but they have been hard to get. The pad drain valves are in the closed position however the drain on the east side of the pad near the lease road entrance is leak a small amount of water. The pad outlet pipe has some algae growth inside the pipe. The company man called the company that drains the pads (who recently drained the pad on 7/26/17) and they will be sending someone out today to determine why the drain is leaking. The company man indicated that if the leak cannot be fixed that he would have the drain valve plugged until a permanent fix can be made. |
1571747739 | 2017-08-16 | Completion Testing | No Violations | On the date of my inspection I found 9 Energy Services running a cement bond log on this well with a wireline truck. Great Lake Wellhead Inc. was also onsite installing wellheads. Currently there are 5 frac tanks and a few miscellaneous pieces of equipment onsite that are associated with the operations currently being performed on the pad. The pad berms and the area immediately adjacent to the pad have been recently hydroseeded. |
409693023 | 2017-10-30 0:00 | CT | No Violations | 0.60 |
471606471 | 2017-8-3 0:00:0 | DD | No Violations | 1.50 |
744795100 | 2017-3-22 0:00: | CS | No Violations | 8.00 |
For data sources see[10]