If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-081-20712 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.3,"lon":-80.69,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Jefferson | |
Municipality: Cross Creek Township | |
Operator Name: ASCENT RESOURCES UTICA LLC | |
Well Pad ID: US-OH-001477 | |
Farm/Lease Name: DICKSON CRC JF | |
License Status: Producing | |
License Date: 2017-05-18 | |
Spud Date: 2017-04-28 | |
Spud Drilling Contractor: | |
Final Drill Date: 2017-07-10 | |
Well Total Depth: 21650.00 ft | |
Configuration: Horizontal | |
Latitude: 40.300000 | |
Longitude: -80.690000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2017-03-10 | Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:3/10/2017, Expired Date:3/10/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
APP | 2017-05-18 | Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:5/18/2017, Expired Date:5/18/2019 12:00:00 PM, Drilling unit acres:602.334, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2017-07-10 | |
Correction to Well | 2017-09-15 | UPDATE TARGET/TAKE PER AS-DRILLED PLAT RCVD 08-28-2017 ALE |
Completion Report Received | 2017-12-11 | |
Record Last Modified | 2017-12-16 | |
Construction Permit Expires | 2018-05-18 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2017-12-15 | 10065 | 10206 | 0 |
2017-12-15 | 19630 | 19741 | 0 |
19630 | 19741 | 0 | |
10065 | 10206 | 0 | |
10065 | 10206 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 09/14/2017 | 10/13/2017 | 9660 | 16,620,900.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | HCl, 5.1 - 7.5% | BJ Services | Acidizing | MSDS and Non-MSDS Ingredients are
listed below the green line. |
Listed Below | 0 | 0.952722 | 1,530,990.0 |
CI-14 | BJ Services | Corrosion Inhibitor | MSDS and Non-MSDS Ingredients are
listed below the green line. |
Listed Below | 0 | 0.00251107 | 4035.19 | |
ResCare IC 300L | BJ Services | Iron Control | MSDS and Non-MSDS Ingredients are
listed below the green line. |
Listed Below | 0 | 0.00750776 | 12064.7 | |
ThinFrac MP-1 | BJ Services | Friction Reducer | MSDS and Non-MSDS Ingredients are
listed below the green line. |
Listed Below | 0 | 0.12057 | 193752 | |
FraCare SI 720 | BJ Services | Scale Inhibitor | MSDS and Non-MSDS Ingredients are
listed below the green line. |
Listed Below | 0 | 0.0555932 | 89336 | |
Water | Operator | Carrier | Water | 7732-18-5 | 100 | 86.2384 | 138,581,000.0 | |
MAQUAT 25:12 | BJ Services | Biocide | MSDS and Non-MSDS Ingredients are
listed below the green line. |
Listed Below | 0 | 0.0235339 | 37818 | |
Formaldehyde | 50-00-0 | 1 | 0.00001569 | 25.2199 | ||||
Sorbian, mono-(9Z)-9octadecenoate | 1338-43-8 | 5 | 0.00352133 | 5658.64 | ||||
Quaternary Ammonium Compound | 68424-85-1 | 5 | 0.00106972 | 1719 | ||||
Fatty Acids | 61790-12-3 | 10 | 0.000156942 | 252.199 | ||||
Potassium Chloride | 7447-40-7 | 1 | 0.000519563 | 834.916 | ||||
Glutaraldehyde | 111-30-8 | 30 | 0.00641833 | 10314 | ||||
Ethanol | 64-17-5 | 5 | 0.00106972 | 1719 | ||||
Hydrochloric Acid | 7647-01-0 | 7.5 | 0.0714698 | 114849 | ||||
Tetrasodium EDTA | 64-02-8 | 0.1 | 0.00007043 | 113.173 | ||||
Methanol | 67-56-1 | 100 | 0.00156942 | 2521.99 | ||||
Sodium Chloride | 7647-14-5 | 5 | 0.00404089 | 6493.55 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.0155869 | 25047.5 | ||||
Citric Acid | 77-92-9 | 60 | 0.00409514 | 6580.73 | ||||
Oxyalkylated Alcohol | 78330-21-9 | 5 | 0.00352133 | 5658.64 | ||||
Acrylamide Modified Acrylic Polymer | 38193-60-1 | 60 | 0.042256 | 67903.6 | ||||
Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 10 | 0.00213944 | 3438 | ||||
Olefin | 64743-02-8 | 5 | 0.00007847 | 126.1 | ||||
Propargyl Alcohol | 107-19-7 | 5 | 0.00007847 | 126.1 | ||||
Crystalline Silica (Quartz) | 14808-60-7 | 100 | 12.5992 | 20,246,400.0 | ||||
Petroleum distillates | 64742-47-8 | 30 | 0.021128 | 33951.8 | ||||
Acetic acid, Potassium Salt | 64-19-7 | 0.1 | 0.00007043 | 113.173 | ||||
2-propenoic, polymer with sodium phosphinate, sodium salt | 71050-62-9 | 20 | 0.0103913 | 16698.3 | ||||
Acetic acid | 127-08-2 | 1 | 0.000704266 | 1131.73 | ||||
Polyoxyalkylenes | 68951-67-7 | 30 | 0.000470825 | 756.597 | ||||
Sorbitan monooleate ethoxylate | 9005-65-6 | 5 | 0.00352133 | 5658.64 | ||||
Calcium Chloride | 10043-52-4 | 5 | 0.00259781 | 4174.58 | ||||
Modified Thiourea Polymer | 68527-49-1 | 7 | 0.000109859 | 176.539 | ||||
Sand, White | BJ Services | Proppant | MSDS and Non-MSDS Ingredients are
listed below the green line. |
Listed Below | 0 | 12.5992 | 20,246,400.0 | |
Other Chemical(s) | BJ Services | See Trade Name(s) List | Water | 7732-18-5 | 92.5 | 0.965767 | 1,551,950.0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2017-09-15 | H2O | 15 | 6831 Bbl | 350873 | BAKER-HUGHES | STAGE 1/56
STAGES 2-55 SEE IMAGES |
2017-10-13 | H2O | 15 | 6006 Bbl | 341350 | BJ Services Company | STAGE 56/56
STAGES 2-55 SEE IMAGES |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | ASCENT RESOURCES UTICA LLC | 990523 | 0 | 52 |
2018 | ASCENT RESOURCES UTICA LLC | 5373945 | 0 | 363 |
2019 | ASCENT RESOURCES UTICA LLC | 565002 | 0 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | ASCENT RESOURCES UTICA LLC | Brine | 12639 | 52 |
2018 | ASCENT RESOURCES UTICA LLC | Brine | 30045 | 363 |
2019 | ASCENT RESOURCES UTICA LLC | Brine | 4221 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1103408593 | 2018-6-20 0:00: | UL | No Violations | 1.00 |
-38673901 | 2017-9-21 0:00: | CT | No Violations | 2.20 |
-490519358 | 2019-12-10 0:00 | UL | No Violations | 1.00 |
0038673901 | 2017-09-21 | Completion Testing | No Violations | On the date of my inspection I found a BJ Services crew rigged up on all 3 wells on the pad for hydraulic fracturing operations. While I was on site I witness BJ Services pump the frac job for stage 11 of 56 on this well and stage 11 of 54 on permit 3408120722. BJ Services pumped approximately 348000 pounds of sand with approximately 6730 barrels of water at rates as high as 84 barrels a minute during this stage. All hazardous materials are within double containment which is in good condition, free of visible punctures or tears. The location is surrounded by a fenced berm with healthy vegetation. The pad drain valves show they are in the closed position. |
0617658325 | 2017-06-28 | Drill / Deepen / Reopen | No Violations | I am onsite to perform a general site inspection. Patterson drilling rig 292 is currently cleaning the hole after reaching a total depth of 8997 feet for their intermediate section. The pad is in good condition and the vegetation on the berms appears healthy. The splash containment on the 500 barrel half-round has been extended to eliminate splashing. This has helped contain most of the mist. However, the fence still has some residue caked on it. I advised Ascent that if the vegetation outside of the berm fence becomes stressed they will have to shut down operations until a better containment solution can be determined. The pad drain valves are closed and do not appear to have any leakage issues. All containment appears to be in good condition and is visibly free of tears and punctures. All hazardous materials are within containment areas. |
0906796088 | 2017-06-21 | Drill / Deepen / Reopen | No Violations | I am onsite to perform a general site inspection. Patterson 292 is currently rigging up on this well to begin drilling the intermediate section. The Ascent company man indicated that they should be ready to begin drilling on 6/22 if all goes well. The berm vegetation all appears healthy. The pad drain valves are closed and do not appear to be leaking. The containment that has been set up at this time appears to be in good shape and is visibly free of punctures or tears. |
1103408593 | 2018-06-20 | UrbanPreliminary Restoration | No Violations | On the day of my inspection I found this pad containing three properly labeled producing wells. Well is plumbed to flowline from the tubing as well as the casing hanger. Both flowlines show 1100 psi. Surface annular shows no pressure, intermediate annular shows 1800 psi, tubing shows 1600 psi and production casing shows 1600 psi. Voicemail was left with Dylan Souther (614-202-9738) of Ascent to inform him of the interemediate annular pressure. Production equipment includes three line heaters, three GPUs, and six sand seperators. Pad outslopes are well vegetated and site meets requirements of OAC 1509.072A for preliminary restoration. |
1493607864 | 2017-04-27 | Drill / Deepen / Reopen | No Violations | I am on site today to witness the cementing of 30 inch conductor casing. Precision Drilling drilled a 36 inch diameter hole to a depth of 100 feet and attempted to run 100 feet of 30 inch diameter 118 pound per foot conductor casing. While running casing, they could not get past the second joint. Precision had to ream the hole out with a 42 inch auger down to 60 feet to get past the blockage then ream the rest of the hole out. Once the hole is cleaned out they will attempt to run the casing again. |
1493657453 | 2017-04-27 | Drill / Deepen / Reopen | No Violations | Onsite with Inspector Scott Scheiner to witness cementing of the 30 inch diameter conductor casing. Cement job was not witnessed, see Inspector Scheiners report this date for more information |
1493961204 | 2017-05-05 | Casing String Witnessed | No Violations | I am on site to witness the running and cementing of 13.375 inch surface casing. Falcon Rig 26 drilled a 17.5 inch diameter hole to a depth of 1515 feet and set 1509 feet of 13.375 inch 61 pound per foot casing. O-Tex established circulation with fresh water, pumped 1600 sacks of class H cement, 1.19 yield and 15.6 pound per gallon, 2 percent calcium chloride, 0.25 pound cello flake per sack. Approximately 90 barrels of cement returned to surface. The wiper plug landed and pressure was increased to approximately 500 pounds per square inch (psi) over pump pressure, the casing held approximately 1115 psi for 5 minutes. |
1513174006 | 2017-12-13 | Production Wells | No Violations | |
1580326159 | 2020-1-29 0:00: | PW | No Violations | 1.00 |
617658325 | 2017-6-28 0:00: | DD | No Violations | 1.80 |
906796088 | 2017-6-21 0:00: | DD | No Violations | 0.80 |
For data sources see[10]