Well Details

Well ID: 34-081-20716
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001489
Farm/Lease Name: GIUSTO W CRC JF
License Status: Producing
License Date: 2017-08-01
Spud Date: 2017-06-22
Spud Drilling Contractor: PIONEER DRILLING
Final Drill Date: 2017-09-11
Well Total Depth: 21125.00 ft
Configuration: Horizontal
Latitude: 40.340000
Longitude: -80.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-03-30 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:3/30/2017, Expired Date:3/30/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2017-08-01 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:8/1/2017, Expired Date:8/1/2019 12:00:00 PM, Drilling unit acres:297.6, Proposed Well Type:OG, Proposed Well Class:EOUT
Reached Total Depth 2017-09-11
Construction Permit Expires 2018-08-01
Completion Report Received 2018-09-12
Record Last Modified 2018-09-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2018-09-12 10073 10144 0
2018-09-12 20906 20958 0
20906 20958 0
10073 10144 0
10073 10144 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 02/18/2018 04/03/2018 9787.2 19,027,900.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SAND-COMMON WHITE-100 MESH Halliburton Proppant Listed Below Listed Below 0 0 0
MC B-8614 Halliburton Biocide Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 88.1543 158,502,000.0
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
FE-2A Halliburton Additive Listed Below Listed Below 0 0 0
GEL 1100 Mountain Supply & Service Gelling Agent Listed Below Listed Below 0 0 0
LP-70 Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0
SAND-PREMIUM WHITE-40/70 Halliburton Proppant Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.288818 519297
FR-76 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
HAI-OS Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
Fatty acids, tall oil Proprietary 30 0.000234911 423
Inorganic salt Proprietary 30 0.0185194 33298
Propargyl alcohol 107-19-7 10 0.00007830 141
POLYMER Not assigned 68 0.00008941 161
Citric acid 77-92-9 60 0.0032748 5889
Ammonium chloride 12125-02-9 10 0.0024519 4409
Organic phosphonate Proprietary 60 0.0147114 26452
Hydrotreated light petroleum distillate 64742-47-8 30 0.0185194 33298
Crystalline silica, quartz 14808-60-7 100 11.5157 20,705,200.0
Methanol 67-56-1 60 0.000499766 899
Reaction product of acetophenone,

formaldehyde, thiourea and oleic acid in dimethyl formamide

68527-49-1 30 0.000234911 423
Hydrochloric acid 7647-01-0 7.5 0.016203 29133
Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl chlorides

68424-85-1 5 0.00106945 1923
Emulsifier 9002-92-0 10 0.00001315 24
Olefins Proprietary 5 0.00009396 172
Acrylamide acrylate copolymer Proprietary 30 0.0185194 33298
Phosphoric acid 7664-38-2 0.1 0.00002139 39
PH BUFFER 8055-55-8 15 0.00001972 36
Ethanol 64-17-5 1 0.000213891 385
Glutaraldehyde 111-30-8 30 0.00641673 11538
Ethoxylated alcohols Proprietary 30 0.000234911 423
Formaldehyde 50-00-0 1 0.00024519 441

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2018-03-20 H2O 15 281817 Gal 350362 Halliburton STAGE 61/61

STAGES 2-60 SEE IMAGES

2018-02-19 H2O 15 354929 Gal 349900 Halliburton STAGE 1/61

STASGES 2-60 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC 4955616 0 183
2019 ASCENT RESOURCES UTICA LLC 1163119 0 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC Brine 33382 183
2019 ASCENT RESOURCES UTICA LLC Brine 8837 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1937157710 2017-8-21 0:00: DD No Violations 2.50
-2134492208 2020-1-15 0:00: PW No Violations 1.00
-776833496 2017-6-22 0:00: CS No Violations 3.50
0348556922 2017-12-13 Completion Testing No Violations On the date of my inspection I found a well maintained access road with a locked gate. The pad is surrounded by a fenced earthen dike covered by healthy vegetation. There are 4 recently drilled wells on the pad surrounded by metal fences. The wells have not been hydraulically fractured yet. Production equipment on the pad includes, 4 sand separators, 4 gas production units, and two 500 barrel tanks within a metal dike. The production equipment is surrounded by concrete barriers. There is a garbage roll off container being stored on the pad near the lease road entrance.
0776833496 2017-06-22 Casing String Witnessed No Violations I am on site today to witness the cementing of 30 inch conductor casing. Precision Drilling drilled a 36 inch diameter hole to a depth of 100 feet and ran 110 feet of 30 inch diameter 118 pound per foot conductor casing. O-Tex pumped 340 sacks of class A cement, 1.2 yield, 15.6 pounds per gallon with 1.5 percent Calcium Chloride and 0.25 pound per sack flow seal. O-Tex then displaced with 80 barrels of water, leaving 10 feet of cement in the casing. A cement basket was ran at approximately 50 feet in case the predicted void at 60 feet opened up during the cement job. Good cement returned to surface and remained static. Cement was brought to approximately 7 feet below ground surface, leaving approximately 18 inches of good cement as a floor in the cellar.
0987562696 2017-06-29 Casing String Witnessed No Violations I am on site to witness the running and cementing of 13.375 inch surface casing. Falcon Rig 26 drilled a 17.5 inch diameter hole to a depth of 1765 feet and set 1754 feet of 13.375 inch 61 pound per foot casing. O-Tex established circulation with fresh water, pumped 35 barrels of bentonite gel spacer followed by 5 barrels of water, then pumped 1840 sacks of class A cement (1.19 yield and 15.6 pound per gallon, 1 percent calcium chloride, 0.25 pound cello flake per sack). The wiper plug was released and O-Tex displaced with 260 barrels of fresh water. By the time the plug landed approximately 100 barrels of cement had returned to surface. When the plug landed, pressure was increased to approximately 500 pounds per square inch (psi) over pump pressure, the casing held approximately 1310 psi for 5 minutes.
1130550014 2018-02-23 Preliminary Restoration No Violations On the day of my inspection I witnessed Halliburton was onsite under direction of Ascent Company man Delbert. This pad is splitting water with the Stone pad, and the other pad is currently receiving water for frac. Stage 11 is finished. Received call from Mr. Niece (ODOT aviation) on 2/21 in regards to crane not having a permit from ODOT. Pad is within 10000 feet of jefferson airpark and ODOT has permits for erections that close to airport. A permanent solar powered light was installed on crane. Outslope of pad is vegetated and stable. Lease road is stable. Site meets requirements of ORC 1509.072A for preliminary restoration.
141038325 2019-7-22 0:00: UL No Violations 1.00
1502889187 2017-08-16 Drill / Deepen / Reopen No Violations On the date of my inspection I found Pioneer rig 77 moving onto the location and rigging up. I was not notified of the rig move by Ascent. I spoke with the company man who thought they had notified me, and he indicated that the rig should be ready to begin drilling on 8/19/17. I informed him that they should have given me a 24 hour notice before moving equipment on to the pad. They are currently rigging up the back yard and staging the air compressors.
1504103084 2017-08-30 Drill / Deepen / Reopen No Violations Today when I arrived onsite to perform a well site inspection I found that the pad had been evacuated to the lease road entrance due to a hydrogen sulfide detection alarm. The gas was detected while drilling the curve at approximately 9575 feet (total vertical depth). The Utica Shale was intercepted at 9446 feet (total vertical depth). I was not notified of the incident while the well permit clearly states that the oil and gas inspector must be notified immediately when hydrogen sulfide is detected in an urban area. I spoke with the Ascent company man Matt about the mistake. After the pad was evacuated, personnel from Compliance Services entered the site with a self-contained breathing apparatus to scan all areas for gas. His detector found a concentration of 35 parts per million in the area near the shakers. The Ascent company man and 3 others entered the site to attempt to re-open the well. When they opened the valve, concentrations between 11 parts per million and 26 parts per million were detected. Ascent plans to run all gas through the flare stack to burn off the gas. They will have multiple sensors in place near the stack to detect any rogue gas emissions. After diverting the gas to the flare, they circulated a full bottoms up and by the time they had fully circulated they were not reading any more gas.
1937157710 2017-08-21 Drill / Deepen / Reopen No Violations On the date of my inspection I found Pioneer rig 77 drilling the intermediate section of this well at approximately 2877 feet. During my inspection I did not find any visible tears or punctures in the containment on site. All of the chemicals were within containment. The pad is surrounded by a fenced earthen dike covered by healthy vegetation. The pad drain valves are in the closed position and do not appear to be leaking.
348556922 2017-12-13 0:00 CT No Violations 0.70
987562696 2017-6-29 0:00: CS No Violations 8.00

For data sources see[10]