If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 34-083-24423 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.28,"lon":-82.39,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Knox | |
| Municipality: Morgan Township | |
| Operator Name: KNOX ENERGY INC. | |
| Well Pad ID: | |
| Farm/Lease Name: VARNER F | |
| License Status: Producing | |
| License Date: 2008-12-09 | |
| Spud Date: 2009-01-02 | |
| Spud Drilling Contractor: KILBARGER DRLG | |
| Final Drill Date: 2009-01-05 | |
| Well Total Depth: 2771.00 ft | |
| Configuration: Vertical | |
| Latitude: 40.280000 | |
| Longitude: -82.390000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| APP | 2008-12-09 | Proposed Formations:OIHO SHALE THRU CLINTON, Issued Date:12/9/2008, Expired Date:12/9/2009 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
| Reached Total Depth | 2009-01-05 | |
| Completion Report Received | 2009-04-22 | |
| Construction Permit Expires | 2009-12-09 | |
| Record Last Modified | 2017-02-15 |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 2009-07-27 | 2602 | 2622 | 34 |
| 2602 | 2622 | 34 | |
| 2602 | 2622 | 34 |
For data sources see[3]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| H2O | 0 | 55000 Gal | 20000 |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2008 | KNOX ENERGY INC. | 0.00 | 0.00 | 0 |
| 2009 | KNOX ENERGY INC. | 4394.00 | 0.00 | 365 |
| 2010 | KNOX ENERGY INC. | 6325.00 | 0.00 | 365 |
| 2011 | KNOX ENERGY INC. | 5739.00 | 0.00 | 365 |
| 2012 | KNOX ENERGY INC. | 5901.00 | 0.00 | 366 |
| 2013 | KNOX ENERGY INC. | 4829.00 | 0.00 | 365 |
| 2014 | KNOX ENERGY INC. | 3689.00 | 0.00 | 365 |
| 2015 | KNOX ENERGY INC. | 3640.00 | 0.00 | 365 |
| 2016 | KNOX ENERGY INC. | 2765.00 | 0.00 | 365 |
| 2017 | KNOX ENERGY INC. | 2613.00 | 0.00 | 365 |
| 2018 | KNOX ENERGY INC. | 2248.00 | 0.00 | 365 |
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2008 | KNOX ENERGY INC. | Brine | 0 | 0 |
| 2009 | KNOX ENERGY INC. | Brine | 645 | 365 |
| 2010 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2011 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2012 | KNOX ENERGY INC. | Brine | 0 | 366 |
| 2013 | KNOX ENERGY INC. | Brine | 62 | 365 |
| 2014 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2015 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2016 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2017 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2018 | KNOX ENERGY INC. | Brine | 0 | 365 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| 1231008853 | 2009-01-03 | Drill / Deepen / Reopen | No Violations | Witnessed placement and cementing of 8 5/8 pipe. |
| 1473576212 | 2014-11-23 | Preliminary Restoration | No Violations | This well is in production there are no violations and meets the requirements to pass the preliminary inspection. |
| 1854078838 | 2014-12-31 | Preliminary Restoration | No Violations | Well is capable of production and is equipt with a motor and pump jack. All drilling equiptment has been removed from site and vegetation surrounding well has been restored. Well site exists within a crop field. The tank battery consists of one 100 barrel tank and a seperator within an earthen dike. Identification can be found at the tank battery. Preliminary restoration passes. |
For data sources see[9]