Well Details

Well ID: 34-085-20179
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Perry Township
Operator Name: MIHALIK PAUL
Well Pad ID:
Farm/Lease Name: DAYKIN F & V
License Status: Producing
License Date: 1973-11-26
Spud Date: 1973-12-10
Spud Drilling Contractor:
Final Drill Date: 1973-12-19
Well Total Depth: 3050.00 ft
Configuration: Vertical
Latitude: 41.780000
Longitude: -81.130000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1973-11-26 3747 UNICORN OIL & GAS CO INC GeoDate 11/26/73
Original Spud 1973-12-10 I.P. GAS SR.
Completed 1973-12-19 I.P. GAS SR.
Reached Total Depth 1973-12-19 I.P. GAS SR.
CO 1994-07-26 28 CGAS EXPLORATION,INC GeoDate 11/26/73
Change of Owner 1999-06-08 Operator changed from 28, CGAS EXPLORATION to 4927, STANDARD NATURAL GAS
Change of Owner 2011-06-01 Operator changed from 4927, STANDARD NATURAL GAS to 7531, MIHALIK PAUL
Record Last Modified 2019-06-04 I.P. GAS SR.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2834 2913 0
2834 2913 0
2834 2913 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 66100 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 MURTHA CONTRACTING INC. 824.00 22.00 365
1990 UNICORN OIL & GAS CO INC 1362.00 0.00 365
1991 UNICORN OIL & GAS CO INC 1210.00 0.00 365
1992 UNICORN OIL & GAS CO INC 1292.00 0.00 365
1994 CGAS EXPLORATION 579.00 0.00 365
1995 CGAS EXPLORATION 1429.00 84.00 365
1996 CGAS EXPLORATION 1180.00 0.00 365
1997 CGAS EXPLORATION 988.00 0.00 365
1998 CGAS EXPLORATION 704.00 0.00 365
2004 MIHALIK PAUL 1063.00 0.00 365
2005 MIHALIK PAUL 1439.00 83.00 365
2006 MIHALIK PAUL 1450.00 0.00 365
2008 MIHALIK PAUL 4173.00 0.00 365
2009 MIHALIK PAUL 4054.00 101.00 365
2010 MIHALIK PAUL 3236.00 0.00 365
2011 MIHALIK PAUL 2712.00 0.00 365
2012 MIHALIK PAUL 2334.00 0.00 366
2013 MIHALIK PAUL 2040.00 75.00 365
2014 MIHALIK PAUL 1952.00 0.00 365
2015 MIHALIK PAUL 1464.00 0.00 335
2016 MIHALIK PAUL 1381.00 0.00 359
2017 MIHALIK PAUL 873.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 MURTHA CONTRACTING INC. Brine 72 365
1990 UNICORN OIL & GAS CO INC Brine 138 365
1991 UNICORN OIL & GAS CO INC Brine 227 365
1992 UNICORN OIL & GAS CO INC Brine 204 365
1994 CGAS EXPLORATION Brine 66 365
1995 CGAS EXPLORATION Brine 0 365
1996 CGAS EXPLORATION Brine 0 365
1997 CGAS EXPLORATION Brine 0 365
1998 CGAS EXPLORATION Brine 0 365
2004 MIHALIK PAUL Brine 157 365
2005 MIHALIK PAUL Brine 196 365
2006 MIHALIK PAUL Brine 196 365
2008 MIHALIK PAUL Brine 1483 365
2009 MIHALIK PAUL Brine 943 365
2010 MIHALIK PAUL Brine 707 365
2011 MIHALIK PAUL Brine 883 365
2012 MIHALIK PAUL Brine 684 366
2013 MIHALIK PAUL Brine 552 365
2014 MIHALIK PAUL Brine 435 365
2015 MIHALIK PAUL Brine 255 335
2016 MIHALIK PAUL Brine 96 359
2017 MIHALIK PAUL Brine 31 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1387065509 2020-8-18 0:00: UP No Violations
-1915952910 2009-11-25 0:00 PW No Violations
-1935759901 2013-11-14 0:00 UP No Violations
-492785382 2018-1-31 0:00: UP No Violations 0.50
0277421446 2017-03-22 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I found that a large tree had fallen onto a portion of the tank battery damaging the horizontal separator unit. The well had been shut-in and no apparent spillage or leaks had resulted. I contacted the well owner who had previously discovered the damage and was in the process of making repairs.
0492785382 2018-01-31 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, fittings and connections were secure and free from leakage or problems. The tank lid was closed. The load line was plugged and secure. Production reports were current. Bond and insurance for this operator were current. There were 2 to 3 inches of fresh snow around the area. I walked and inspected the production elements as well as the wooded portions around the well and battery and found no indications of problems. The tree fall that had occurred prior to my last inspection had been removed and the damage to the system elements repaired.
0785864256 2016-09-02 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of ths inspection, I observed th following: a wellhad with pump jack system and associatd tank battery located in a small clearing in an otherwise wooded area. The tank batery was comprised of one 210-barrel steel production tank and separator unit. The load line valves were closed and secure, but were not locked. The tank lid was closed and sealed. Fittings and connections were secure and free from signs of leakage. There was secondary containment and it was intact and free from signs of leakage or spills. I noted that there was an indirect fire heater unit configured within the tank battery. I notifed Paul Mihalik that the indirect heater must be at least 50 feet from the well and from the storage tank, so it may not be operated in its current configuration.
1423168142 2015-02-05 Work Over Reconditioning No Violations I inspected this well as part of routine inspection activity. My inspection found the following: Access to the well is via a dedicated access road located just east of the Red Mill Golf facility. At the time of this inspection, there are 14+ inches of snow cover in the area. As such, portions of the producing system are under snow cover. The access road has not been plowed, access to the wellhead and battery are accessible by foot only. Connections at the wellhead pump jack and tank battery are secure with no signs of leakage. The ID sign is missing. I advised Paul Mihalik about the need for ID.
1915952910 2009-11-25 Production Wells No Violations There were no violations at the time of inspection.
1935759901 2013-11-14 UrbanProduction Wells No Violations The producing unit is comprised of a pump jack and aboveground storage tank (AST) battery. The wellhead and battery are not enclosed. The battery consists of 1 210-barrel production tank, and separator unit. The is no ID placard for the unit. Secondary containment and spacing are in compliance. The unit is producing and no problems otherwise observed. I contacted and advised Paul Mihalik about the signage issues.
277421446 2017-3-22 0:00: UP No Violations 0.50
785864256 2016-9-2 0:00:0 UP No Violations 1.00

For data sources see[9]