Well ID: 34-085-20309 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.74,"lon":-81.22,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Painesville Township | |
Operator Name: ALLIED OIL FIELD SERVICES LTD | |
Well Pad ID: | |
Farm/Lease Name: CEI SCHEDULE I | |
License Status: Producing | |
License Date: 1983-09-09 | |
Spud Date: 1983-11-24 | |
Spud Drilling Contractor: ARMSTRONG DRLG | |
Final Drill Date: 1983-11-29 | |
Well Total Depth: 3092.00 ft | |
Configuration: Vertical | |
Latitude: 41.740000 | |
Longitude: -81.220000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-11-17 | 540 DIAMOND SHAMROCK CHEM CO GeoDate 11/17/81 |
CO | 1983-09-09 | 540 DIAMOND SHAMROCK CHEM CO GeoDate 9/9/83 |
Oil and Gas | 1983-09-09 | Issued Date 9/9/83 Expired Date 3/7/84 Acres 0021000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03092 Proposed Drill Depth 03092 |
Original Spud | 1983-11-24 | R.I. 9-10-83 |
Completed | 1983-11-29 | R.I. 9-10-83 |
Reached Total Depth | 1983-11-29 | R.I. 9-10-83 |
Construction Permit Expires | 1984-03-07 | R.I. 9-10-83 |
Completion Report Received | 1984-10-11 | R.I. 9-10-83 |
CO | 1991-10-10 | 4128 MIDGARD ENERGY CO GeoDate 9/9/83 |
Change of Owner | 1998-07-22 | Operator changed from 4128, MIDGARD ENERGY CO to 3847, HALL & HORNING SERV INC |
Change of Owner | 2010-01-25 | Operator changed from 3847, HALL & HORNING SERV INC to 8602, ALLIED OIL FIELD SERVICES LTD |
Record Last Modified | 2015-09-24 | R.I. 9-10-83 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 2923 | 2966 | 18 |
2916 | 2948 | 0 | |
1997-06-29 | 2916 | 2948 | 0 |
2923 | 2966 | 18 | |
2916 | 2948 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1200 Bbl | 30000 | FRAC: H2O,SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | DIAMOND SHAMROCK CHEM CO | 16055.00 | 0.00 | 365 |
1986 | DIAMOND SHAMROCK CHEM CO | 14282.00 | 0.00 | 365 |
1987 | DIAMOND SHAMROCK CHEM CO | 15497.00 | 0.00 | 365 |
1988 | DIAMOND SHAMROCK CHEM CO | 10968.00 | 0.00 | 365 |
1989 | DIAMOND SHAMROCK CHEM CO | 7057.00 | 0.00 | 365 |
1990 | DIAMOND SHAMROCK CHEM CO | 4843.00 | 0.00 | 365 |
1991 | MIDGARD ENERGY CO | 4552.00 | 0.00 | 365 |
1992 | MIDGARD ENERGY CO | 3371.00 | 0.00 | 365 |
1993 | MIDGARD ENERGY CO | 2759.00 | 0.00 | 365 |
1995 | MIDGARD ENERGY CO | 1471.00 | 0.00 | 357 |
1996 | MIDGARD ENERGY CO | 891.00 | 0.00 | 366 |
1998 | HALL & HORNING SERV INC | 1975.00 | 0.00 | 365 |
1999 | HALL & HORNING SERV INC | 3516.00 | 0.00 | 365 |
2000 | HALL & HORNING SERV INC | 2456.00 | 86.00 | 365 |
2001 | HALL & HORNING SERV INC | 2271.00 | 0.00 | 365 |
2002 | HALL & HORNING SERV INC | 617.00 | 29.00 | 365 |
2003 | HALL & HORNING SERV INC | 1795.00 | 0.00 | 365 |
2004 | HALL & HORNING SERV INC | 1231.00 | 0.00 | 365 |
2005 | HALL & HORNING SERV INC | 765.00 | 0.00 | 365 |
2006 | HALL & HORNING SERV INC | 498.00 | 0.00 | 365 |
2007 | HALL & HORNING SERV INC | 570.00 | 37.00 | 365 |
2008 | HALL & HORNING SERV INC | 847.00 | 0.00 | 366 |
2009 | HALL & HORNING SERV INC | 704.00 | 0.00 | 195 |
2010 | ALLIED OIL FIELD SERVICES LTD | 610.00 | 0.00 | 365 |
2011 | ALLIED OIL FIELD SERVICES LTD | 964.00 | 0.00 | 365 |
2012 | ALLIED OIL FIELD SERVICES LTD | 1094.00 | 0.00 | 366 |
2013 | ALLIED OIL FIELD SERVICES LTD | 1112.00 | 0.00 | 365 |
2014 | ALLIED OIL FIELD SERVICES LTD | 963.00 | 0.00 | 365 |
2015 | ALLIED OIL FIELD SERVICES LTD | 720.00 | 0.00 | 365 |
2016 | ALLIED OIL FIELD SERVICES LTD | 0.00 | 0.00 | 0 |
2017 | ALLIED OIL FIELD SERVICES LTD | 0.00 | 0.00 | 0 |
2018 | ALLIED OIL FIELD SERVICES LTD | 0.00 | 0.00 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1108245461 | 2017-7-18 0:00: | UP | No Violations | 0.50 |
-1848543514 | 2004-1-16 0:00: | PW | No Violations | |
-281552652 | 2004-11-23 0:00 | PW | No Violations | |
-644356941 | 2004-4-19 0:00: | PW | No Violations | |
-651949170 | 2014-3-28 0:00: | UP | No Violations | |
000PL14428 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0281552652 | 2004-11-23 | Production Wells | No Violations | |
0644356941 | 2004-04-19 | Production Wells | No Violations | ID posted violation corrected. |
0651949170 | 2014-03-28 | UrbanProduction Wells | No Violations | The unit is producing with no observed problems, ID is present, secondary containment are present. Load-outs are bull-plugged. No indications of leaks, spills, or other problems. |
0824980905 | 2012-11-28 | Production Wells | No Violations | The unit consists of a 1-tank battery (TB) with mechanical separator, and two in-ground concrete brine tanks, enclosed in a 6-foot fence. The spacing is in accordance with the rule, and the valves and mechanicals are in good repair. I did not observe any signs of leaking product or gas vapors. The wellhead is fitted with a mechanical plunger lift. The tank battery dike is adequate. Unit ID is good. The TB gate needs locked. I called Cindy Moore of Allied Oil Field Serv., regarding the need for a gate lock. Cindy indicated that the problem would be corrected with the next two weeks. |
1093672011 | 2005-02-15 | Production Wells | No Violations | |
1108245461 | 2017-07-18 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery in an otherwise undeveloped parcel. Fittings and connections were secure and free from leakage. A portion of the battery enclosure had fallen down. Also, the well enclosure gate was open. I contacted the well tender (Pierre Delafransico) about the need for maintenance. He indicated that he would tend to it as soon as possible. The shared-use access to the well and battery was in good condition. |
1377795641 | 2013-08-29 | UrbanProduction Wells | No Violations | The producing unit consists of a production wellhead with mechanical plunger lift and aboveground storage tank battery. The battery includes one steel 100-barrel production tank and in-ground brine unit, and separator. There is also a dominion metering run. The battery and wellhead are enclosed in chain-link fences. The wellhead is significantly overgrown with weeds. The unit ID is present at the battery. I did not observe any problems or signs of spills or leakage. |
1412694245 | 2014-10-07 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The wellhead and tank battery are located on an undeveloped parcel on the south side of Fairport-Nursery Road. The surrounding area is mostly overgrown with wild vegetation. The well is producing and the production records are current. I did not observe any signs of spills, leaks or other problems. |
1529331512 | 2018-06-18 | UrbanProduction Wells | Violations Noted | I inspected this well location as part of routine inspection activity, At the time of my inspection, I noted the following: a wellhead with plunger-lift system and associated tank battery. The well was shut-in and not in active production. There was not an active chart record. The various fittings and connections were secure with no signs of leakage or problems. I noted the following deficiencies: the entry gate to the tank battery enclosure was unlocked and unsecure. There was no well identification signage present. The owner must remedy the aforementioned deficiencies by no later than 07/18/18. Please contact Inspector Stephen Tompkins at 330-907-4647 with any questions regarding this compliance notice. |
1543424799 | 2018-11-28 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1529331512, regarding identification and locks on man doors needing to be installed. At the time of this inspection, the well was equipped with a plunger lift assembly and not in production. The valve on the tubing was closed and locked out. The well was fenced but a lock was still needed on the man door. Legible identification was located at the well. The tank battery was comprised of one 100 BBL tank and a mechanincal separator. A Dominion East Ohio master meter was also present within the fenced battery. The separator chart was no present but there was a domestic line plumbed off the separator with a regulator, drip bottle and meter. The valve on the domestic line was open. The tank battery was diked and had legible identification. The man door to the tank battery still needed a lock installed. The lease access was stable.
Allied Oil Field Services LTD still needs to: 1) Install locks on both fence man doors. |
1584979070 | 2020-3-23 0:00: | UP | No Violations | |
1741751745 | 2003-10-07 | Production Wells | No Violations | 100 BBL -seperator-2 buried brine tanks.Well (rabbit) |
1848543514 | 2004-01-16 | Production Wells | Violations Noted | |
1871050316 | 2010-03-18 | Production Wells | No Violations | There were no violations at the time of inspection. |
824980905 | 2012-11-28 0:00 | PW | No Violations | |
PL14428 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1529331512 | US-OH-114658 | 2018-06-22 | ID (a-i) | |
1529331512 | US-OH-114659 | 2018-06-22 | LOCKS | |
1848543514 | US-OH-118492 | 2004-01-20 | Failure to legibly identify well |
For data sources see[9]