X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-20383

Well Details

Well ID: 34-085-20383
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Painesville Township
Operator Name: MIHALIK PAUL
Well Pad ID:
Farm/Lease Name: TRESGER
License Status: Producing
License Date: 1982-07-14
Spud Date: 1982-08-15
Spud Drilling Contractor: H.L.H. DRLG
Final Drill Date: 1982-08-19
Well Total Depth: 2997.00 ft
Configuration: Vertical
Latitude: 41.750000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1982-07-14 858 DRILLEX INC GeoDate 7/14/82
Oil and Gas 1982-07-14 Issued Date 7/14/82 Expired Date 1/1/83 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 02997 Proposed Drill Depth 02997
Original Spud 1982-08-15 PERMIT EXPIRED.
Completed 1982-08-19 PERMIT EXPIRED.
Reached Total Depth 1982-08-19 PERMIT EXPIRED.
Construction Permit Expires 1983-01-01 PERMIT EXPIRED.
Completion Report Received 1985-01-10 PERMIT EXPIRED.
Change of Owner 2003-10-06 Operator changed from 858, DRILLEX INC to 7531, MIHALIK PAUL
Record Last Modified 2017-02-15 PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 2857 2896 0
2857 2896 0
2006-09-11 2868 2895 2
2868 2895 2
2857 2896 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 40000 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DRILLEX INC 11702.00 54.00 0
1985 DRILLEX INC 8411.00 0.00 365
1986 DRILLEX INC 3683.00 0.00 365
1987 DRILLEX INC 2828.00 0.00 365
1988 DRILLEX INC 2314.00 0.00 365
1989 DRILLEX INC 2569.00 0.00 365
1990 DRILLEX INC 2847.00 0.00 365
1991 DRILLEX INC 2273.00 9.00 365
1992 DRILLEX INC 2578.00 0.00 365
1993 DRILLEX INC 1366.00 0.00 365
1994 DRILLEX INC 646.00 0.00 365
1995 DRILLEX INC 767.00 0.00 365
1996 DRILLEX INC 1133.00 0.00 365
1998 DRILLEX INC 1369.00 0.00 365
1999 DRILLEX INC 839.00 0.00 365
2000 DRILLEX INC 1059.00 0.00 365
2001 DRILLEX INC 895.00 0.00 365
2002 DRILLEX INC 5348.00 0.00 365
2003 DRILLEX INC 4331.00 0.00 365
2004 MIHALIK PAUL 1317.00 0.00 365
2005 MIHALIK PAUL 1201.00 0.00 365
2006 MIHALIK PAUL 1857.00 0.00 365
2008 MIHALIK PAUL 1751.00 0.00 365
2009 MIHALIK PAUL 898.00 0.00 365
2010 MIHALIK PAUL 753.00 0.00 365
2011 MIHALIK PAUL 1157.00 0.00 365
2012 MIHALIK PAUL 980.00 0.00 366
2013 MIHALIK PAUL 954.00 0.00 365
2014 MIHALIK PAUL 1706.00 0.00 365
2015 MIHALIK PAUL 941.00 0.00 210
2016 MIHALIK PAUL 576.00 0.00 146
2017 MIHALIK PAUL 925.00 0.00 230

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DRILLEX INC Brine 280 0
1985 DRILLEX INC Brine 165 365
1986 DRILLEX INC Brine 271 365
1987 DRILLEX INC Brine 235 365
1988 DRILLEX INC Brine 73 365
1989 DRILLEX INC Brine 45 365
1990 DRILLEX INC Brine 0 365
1991 DRILLEX INC Brine 48 365
1992 DRILLEX INC Brine 152 365
1993 DRILLEX INC Brine 67 365
1994 DRILLEX INC Brine 66 365
1995 DRILLEX INC Brine 61 365
1996 DRILLEX INC Brine 28 365
1998 DRILLEX INC Brine 22 365
1999 DRILLEX INC Brine 15 365
2000 DRILLEX INC Brine 0 365
2001 DRILLEX INC Brine 23 365
2002 DRILLEX INC Brine 101 365
2003 DRILLEX INC Brine 46 365
2004 MIHALIK PAUL Brine 113 365
2005 MIHALIK PAUL Brine 30 365
2006 MIHALIK PAUL Brine 42 365
2008 MIHALIK PAUL Brine 82 365
2009 MIHALIK PAUL Brine 21 365
2010 MIHALIK PAUL Brine 36 365
2011 MIHALIK PAUL Brine 19 365
2012 MIHALIK PAUL Brine 0 366
2013 MIHALIK PAUL Brine 23 365
2014 MIHALIK PAUL Brine 70 365
2015 MIHALIK PAUL Brine 10 210
2016 MIHALIK PAUL Brine 0 146
2017 MIHALIK PAUL Brine 0 230

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1670469686 2013-5-13 0:00: UP No Violations
000PL14413 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0726680165 2018-11-28 UrbanProduction Wells No Violations I conducted an inspection on this well. At the time of this inspection, the well was equipped with a Concoil plunger lift assembly. The well was in production during this inspection. The tank battery consisted of one 100 BBL tank and a heater treater separator. Valves on the separator were open and the chart showed production. Wells 2-0382 and 2-0384 were also produced into this tank battery. The 100 BBL tank was diked but the separator was located outside of the diked area. Legible identification was located at the well and tank battery. The lease access was stable. No violations observed.
1418834090 2014-12-17 UrbanProduction Wells No Violations I inspected the location of this producing unit as part of routine inspection activity. The wellhead and battery are located in an un-developed portion of the former Fairway Pines Golf Club. At the wellhead there is valve-tree and concoil system. The battery is comprised of 1 100-barrel production tank and 1 100-barrel brine tank, and separator. The well elements are in good repair with no signs of leakage or problems. ID signage and secondary containment are present at the battery. Load-outs are bull-plugged. According to the signage, the battery is shared with the #8 (#2-0382) and the # 10 (#2-384) units. There is no ID at these wellheads. I asked Paul Mihalik to begin working on getting signage at the wellheads.
1670469686 2013-05-13 UrbanProduction Wells No Violations The producing unit consists of the following elements: a concoil unit at the wellhead and a tank battery with 1 100-barrel steel tank, and associated mechanical separator. The tank battery is shared with the Tresger 8 and 10 units (API # 3408520382 and 3408520384)). Secondary containment is present and adequate. The loadout valve needs locked. Identification is needed at the wellhead. I contacted Paul Mihalik regarding the deficiencies. He indicated that theft of signs has been a problem in this area, but he would work to resolve the issues in the next two weeks.
726680165 2018-11-28 0:00 UP No Violations
PL14413 PL No Violations

For data sources see[9]

References