If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-20414 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.67,"lon":-81.33,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: GONZOIL INC | |
Well Pad ID: | |
Farm/Lease Name: MERKEL (OSAIR INC) | |
License Status: Final Restoration | |
License Date: 2016-12-05 | |
Spud Date: 1983-06-10 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1983-06-13 | |
Well Total Depth: 3170.00 ft | |
Configuration: Vertical | |
Latitude: 41.670000 | |
Longitude: -81.330000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1982-10-26 | 957 OSAIR INC GeoDate 10/26/82 |
Oil and Gas | 1982-10-26 | Issued Date 10/26/82 Expired Date 4/24/83 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1983-04-20 | 957 OSAIR INC GeoDate 4/20/83 |
Oil and Gas | 1983-04-20 | Issued Date 4/20/83 Expired Date 10/17/83 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03170 Proposed Drill Depth 03170 |
Original Spud | 1983-06-08 | R.I. R.L. 4-23-83 |
Completed | 1983-06-13 | R.I. R.L. 4-23-83 |
Reached Total Depth | 1983-06-13 | R.I. R.L. 4-23-83 |
Completion Report Received | 1985-02-11 | R.I. R.L. 4-23-83 |
Change of Owner | 2006-06-07 | Operator changed from 957, OSAIR INC to 8039, MERKEL JUNE G |
Change of Owner | 2016-11-29 | Operator changed from 8039, MERKEL JUNE G to 3434, GONZOIL INC |
APP | 2016-12-05 | Proposed Formations:CLINTON, Issued Date:12/5/2016, Expired Date:12/5/2017 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2017-07-13 | R.I. R.L. 4-23-83 |
Construction Permit Expires | 2017-12-05 | R.I. R.L. 4-23-83 |
Record Last Modified | 2018-04-17 | R.I. R.L. 4-23-83 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3011 | 3084 | 0 |
3011 | 3084 | 0 | |
2006-09-11 | 3039 | 3083 | 17 |
3039 | 3083 | 17 | |
3011 | 3084 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 40000 | FRAC;H2O,SAND,N2 | ||
N2 | 0 | 240 Mscf | 0 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1833806470 | 2017-7-12 0:00: | PB | No Violations | 10.00 |
-826999561 | 2017-7-11 0:00: | PB | No Violations | 1.50 |
000PL14397 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0826999561 | 2017-07-11 | Plug / Plug Back | No Violations | I was on location to inspect and observe preliminary activities associated with plugging and abandonment. Crews had stopping rod removal when the well began to unload gas and fluids. Reportedly, the well blew down and became stabilized within 45 minutes. At the time of my inspection, the well was quiet. The pit was in good condition with sufficient free-board to contain the produced fluids. Crews had resumed rod removal and this activity was projected to take up the remainder of the day. |
1305934850 | 2017-07-31 | Final Restoration | No Violations | I inspected this well location as a follow-up to plugging and abandonment that was executed previously. At the time of this inspection, I observed the following: the well has been plugged, the well casing has been cut down and lid attached with API #. The former tank battery system has been removed. The area of the well and battery and surrounding areas was undergoing active earthwork for a new housing development. No further action is needed for final restoration. |
1500050515 | 2017-07-13 | Plug / Plug Back | No Violations | I was on location to witness plugging and abandonment activity being performed by Bishop Well Service under contract to Gonzoil Inc. During my site inspection, the top surface plug consisting of 9-sack grout was top-loaded without incident or problems. A metal lid was affixed to the surface casing and the well was buried per rule. Details of the activities may be found in the associated plugging and abandonment report. |
1624636744 | 2012-11-27 | UrbanProduction Wells | No Violations | The unit consists of the remnants of tank battery (TB) with one 210-bbl production tank and mechanical separator enclosed in a 6-foot fence. The wellhead consists of a pump jack unit located 100 feet north, and is enclosed within a 6-foot fence. The unit is shut-in and in disrepair. Attempts to contact the owner of record have been unsuccessful. Records indicate that bonding and insurance are not current. Will recommend placing this unit on the list of idle and orphan wells. |
1645431475 | 2014-11-03 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. The wellhead pump jack and battery are located on Maple St. a short distance eat of Station Street and adjacent to a vacant greenhouse facility. The pump jack is idle and overgrown with vegetation. The battery is comprised of a 210-barrel tank and separator. The battery has become overgrown, lacks any kind of identification. The unit is not in production and has not been maintained. There are no production records on file. The well shall be plugged within 180 days or be subject to further enforcement action. |
1833806470 | 2017-07-12 | Plug / Plug Back | No Violations | I was on location to witness plugging and abandonment activity being performed by Bishop Well Service under contract to Gonzoil Inc. During my site inspection, the well was blown down and plugging was executed without incident or problems. Details of the activities may be found in the associated plugging and abandonment report. |
PL14397 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1645431475 | US-OH-116210 | 2017-10-13 | 9-05E1 | ID (a-i) |
1645431475 | US-OH-116211 | 2017-10-13 | NONEC | Statement of annual production not filed |
For data sources see[5]