{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.74,"lon":-81.16,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Perry Township | |
Operator Name: FUTURE PRODUCTION INC | |
Well Pad ID: | |
Farm/Lease Name: ROUGHT LAWRENCE CAROL & ROBERT | |
License Status: Producing | |
License Date: 1983-12-13 | |
Spud Date: 1984-01-13 | |
Spud Drilling Contractor: INMAN WELL DRLG | |
Final Drill Date: 1984-01-19 | |
Well Total Depth: 3100.00 ft | |
Configuration: Vertical | |
Latitude: 41.740000 | |
Longitude: -81.160000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1982-11-01 | 83 DIXIE ENERGY CO INC GeoDate 11/1/82 |
Oil and Gas | 1982-11-01 | Issued Date 11/1/82 Expired Date 4/30/83 Acres 0033000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1983-04-29 | 83 DIXIE ENERGY CO INC GeoDate 4/29/83 |
Oil and Gas | 1983-04-29 | Issued Date 4/29/83 Expired Date 10/26/83 Acres 0033860 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1983-11-03 | 83 DIXIE ENERGY CO INC GeoDate 11/3/83 |
Oil and Gas | 1983-11-03 | Issued Date 11/3/83 Expired Date 5/1/84 Acres 0033860 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1983-12-13 | 83 DIXIE ENERGY CO INC GeoDate 12/13/83 |
Oil and Gas | 1983-12-13 | Issued Date 11/3/83 Expired Date 5/1/84 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03100 Proposed Drill Depth 03100 |
Original Spud | 1984-01-13 | R.I. 11-5-83, R.I. 4-30-83, RL 12-17-83 |
Completed | 1984-01-19 | R.I. 11-5-83, R.I. 4-30-83, RL 12-17-83 |
Reached Total Depth | 1984-01-19 | R.I. 11-5-83, R.I. 4-30-83, RL 12-17-83 |
Construction Permit Expires | 1984-05-01 | R.I. 11-5-83, R.I. 4-30-83, RL 12-17-83 |
Completion Report Received | 1984-11-13 | R.I. 11-5-83, R.I. 4-30-83, RL 12-17-83 |
CO | 1994-03-08 | 3370 FUTURE PRODUCTION INC GeoDate 12/13/83 |
Record Last Modified | 2017-02-15 | R.I. 11-5-83, R.I. 4-30-83, RL 12-17-83 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 2904 | 2980 | 0 |
2904 | 2980 | 0 | |
2006-09-11 | 2932 | 2976 | 19 |
2932 | 2976 | 19 | |
2904 | 2980 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 400 Mscf | 0 | SCF N2 | ||
H2O | 0 | 300 Bbl | 40000 | FRAC: H2O,SAND,N2 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2001 | FUTURE PRODUCTION INC | 87.00 | 0.00 | 122 |
2002 | FUTURE PRODUCTION INC | 66.00 | 0.00 | 98 |
2003 | FUTURE PRODUCTION INC | 11.00 | 3.00 | 47 |
2004 | FUTURE PRODUCTION INC | 270.00 | 4.00 | 215 |
2006 | FUTURE PRODUCTION INC | 543.00 | 14.00 | 365 |
2007 | FUTURE PRODUCTION INC | 265.00 | 2.00 | 365 |
2008 | FUTURE PRODUCTION INC | 381.00 | 11.00 | 365 |
2009 | FUTURE PRODUCTION INC | 440.00 | 9.00 | 364 |
2011 | FUTURE PRODUCTION INC | 384.00 | 24.00 | 365 |
2012 | FUTURE PRODUCTION INC | 606.00 | 46.00 | 366 |
2013 | FUTURE PRODUCTION INC | 514.00 | 25.00 | 364 |
2014 | FUTURE PRODUCTION INC | 622.00 | 17.00 | 364 |
2015 | FUTURE PRODUCTION INC | 246.00 | 22.00 | 364 |
2016 | FUTURE PRODUCTION INC | 474.00 | 9.00 | 364 |
2017 | FUTURE PRODUCTION INC | 407.00 | 8.00 | 364 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2001 | FUTURE PRODUCTION INC | Brine | 0 | 122 |
2002 | FUTURE PRODUCTION INC | Brine | 0 | 98 |
2003 | FUTURE PRODUCTION INC | Brine | 125 | 47 |
2004 | FUTURE PRODUCTION INC | Brine | 48 | 215 |
2006 | FUTURE PRODUCTION INC | Brine | 192 | 365 |
2007 | FUTURE PRODUCTION INC | Brine | 75 | 365 |
2008 | FUTURE PRODUCTION INC | Brine | 40 | 365 |
2009 | FUTURE PRODUCTION INC | Brine | 33 | 364 |
2011 | FUTURE PRODUCTION INC | Brine | 295 | 365 |
2012 | FUTURE PRODUCTION INC | Brine | 165 | 366 |
2013 | FUTURE PRODUCTION INC | Brine | 195 | 364 |
2014 | FUTURE PRODUCTION INC | Brine | 180 | 364 |
2015 | FUTURE PRODUCTION INC | Brine | 90 | 364 |
2016 | FUTURE PRODUCTION INC | Brine | 10 | 364 |
2017 | FUTURE PRODUCTION INC | Brine | 6 | 364 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-128446414 | 2017-8-7 0:00:0 | UP | No Violations | 1.00 |
-1746693771 | 2018-5-1 0:00:0 | UP | No Violations | |
-1968855153 | 2017-7-13 0:00: | UP | No Violations | 1.00 |
-802040648 | 2015-3-10 0:00: | UP | No Violations | 0.50 |
000PL14396 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0107739568 | 2017-08-07 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to Chiefs Order #2014- 459 issued for lack of current insurance certificate. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate chain-link enclosures. The well was in active production as evidenced by an active chart in the chart recorder which was current as of the day of this inspection as well as open and active flow-line connections at the wellhead and battery. I had contacted the owner/operator Brett Huntsman on 06/30/2017 who confirmed that Future Productions Inc. was without insurance at the time of the telephone contact and was aware that continuing to operate the well was in violation of the referenced order. At the time of this inspecton, no further action had been taken by Future Production Inc. regarding the stipulations of the associated Chiefs Order. |
0128446414 | 2017-08-07 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to Chiefs Order #2014- 459 issued for lack of current insurance certificate. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate chain-link enclosures. The well was in active production as evidenced by an active chart in the chart recorder which was current as of the day of this inspection as well as open and active flow-line connections at the wellhead and battery. I had previously contacted the owner/operator Brett Huntsman on 06/30/2017 who confirmed that Future Productions Inc. was without insurance at the time of the telephone contact and was aware that continuing to operate the well was in violation of the referenced order. At the time of this inspection, no further action had been taken by Future Production Inc. regarding the stipulations of the associated Chiefs Order. |
0802040648 | 2015-03-10 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. The unit is comprised of a wellhead with pump jack system and a 2-tank battery (1 100 barrel steel production tank, 1 25-barel plastic brine tank, and 1 in-ground concrete brine holding structure) and separator unit in separate chain-link enclosures. Gates are locked. Load-outs are plugged and secure. Connections and fittings are secure and free from signs of leakage or problems. ID signage is present and accurate. The surrounding areas are snow-covered. |
0962763039 | 2003-08-04 | Production Wells | No Violations | TB 100 BBL, septic ,seperator |
0979246935 | 2018-05-30 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to Chiefs Order #2014- 459 issued for lack of current insurance certificate. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate chain-link enclosures. The well was shut-in and not in active production, pending actions by the owner to restore insurance. |
107739568 | 2017-8-7 0:00:0 | UP | No Violations | |
1082437148 | 2018-08-30 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to Chiefs Order #2014-459. At the time of this inspection, I noted the following: the well and associated production elements consisting of a 100-barrel steel stock tank, mechanical separator, and concrete brine vault remained in a similar condition. |
1099508884 | 2018-06-28 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to Chiefs Order #2014- 459 issued for lack of current insurance certificate. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate chain-link enclosures. The well was shut-in and not in active production, pending actions by the owner to restore insurance. Insurance remained lapsed at the time of this inspection. |
1106068959 | 2015-10-29 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. The well and battery are located in an open farm field and accessed directly from Shepard Road. Fittings and connections at the battery are secure and free from signs of leakage or problems. The enclosure gates are locked and secure. Load lines are plugged and secure. Secondary containment is intact and free from standing water or signs of leakage. Signage is present and accurate. Production reports are current. I walked the area surrounding the well and the battery and did not observe any signs of impact relating to the on-going production activity. |
1407308964 | 2010-04-07 | Production Wells | No Violations | There were no violations at the time of inspection. |
1429079916 | 2019-04-08 | UrbanProduction Wells | No Violations | I conducted an order follow-up inspection for Chiefs Order (#2014-459) which issued a legal hold on production as of 10/15/2014 due to lack of current liability insurance. At the time of this inspection, the well was in production. The chart on the sales line in the tank battery location, also showed production. |
1486585392 | 2017-07-03 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to Chiefs Order #2014- 459 issued for lack of current insurance certificate. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate chain-link enclosures. The well was in active production as evidenced by an active chart in the chart recorder which was current as of the day of this inspection as well as open and active flow-line connections at the wellhead and battery. I contacted the owner/operator Brett Huntsman on 06/30/2017 who confirmed that Future Productions Inc. was without insurance at the time of the telephone contact and was aware that continuing to operate the well was in violation of the referenced order. |
1496685627 | 2017-06-02 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to Chiefs Order #2014-459, issued on October 15, 2014 for failure to maintain liability insurance coverage in accordance with Ohio Revised Code (ORC) 1509.07. As part of the order, Future Productions, Inc. (Owner) was directed to suspend all oil and gas operations in the State of Ohio. At the time of this inspection, the Owner had failed to correct the deficiency. I observed the well to be in active production. I also noted that no production reports had been filed since 2012. I contacted Brett Huntsman on 06/05/2017 and advised that the Owner was in violation of the referenced Chiefs Order and must suspend operations pending the renewal of liability insurance. We agreed the Owner must resolve within two weeks, or by 06/16/2017. |
1513957364 | 2017-12-22 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to Chiefs Order #2014- 459 issued for lack of current insurance certificate. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate chain-link enclosures. The well was in active production as evidenced by an active chart in the chart recorder which was current as of the day of this inspection as well as open and active flow-line connections at the wellhead and battery. At the time of this inspection, no further action had been taken by Future Production Inc. regarding the stipulations of the associated Chiefs Order. There was no current liability insurance. |
1569939549 | 2019-10-1 0:00: | UP | No Violations | |
1746693771 | 2018-05-01 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to Chiefs Order #2014- 459 issued for lack of current insurance certificate. At the time of this inspection, I observed the following: The well was in active production as evidenced by an active chart in the chart recorder which was current as of the day of this inspection as well as open and active flow-line connections at the wellhead and battery. At the time of this inspection, no further action had been taken by Future Production Inc. regarding the stipulations of the associated Chiefs Order. There was no current liability insurance. I attempted to contact the owner on the day of this inspection. As of the date of this report filing, the owner had not responded to a voice mail message. |
1788321534 | 2017-11-21 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to Chiefs Order #2014- 459 issued for lack of current insurance certificate. I have advised the owner previously that he may not operate the wells without insurance. At the time of this inspection this well was in active production with active and current chart recorder showing active production. |
1841977623 | 2013-09-24 | UrbanProduction Wells | No Violations | The producing wellhead is fitted with a pumpjack unit. The associated aboveground storage tank (AST) battery is comprised of 1 100-barrel steel production tank, 1 25-barrel poly tank, and an in-ground concrete brine tank system. The secondary containment is adequate. Both the wellhead and batetry are in chain-link fences. There is no identifying placard anywhere here. |
1968855153 | 2017-07-13 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to a Chiefs Order (#2014-459) which issued a legal hold on production as of 10/17/2014 due to lack of current liability insurance. At the time of this inspection, the well remained in production with active flow-line connections and chart recorder which was active and current. |
206817140 | 2020-3-10 0:00: | UP | No Violations | |
728428874 | 2019-8-6 0:00:0 | UP | No Violations | |
962763039 | 2003-8-4 0:00:0 | PW | No Violations | |
979246935 | 2018-5-30 0:00: | UP | No Violations | 1.00 |
PL14396 | PL | No Violations |