X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-20574

Well Details

Well ID: 34-085-20574
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Painesville Township
Operator Name: ALLIED OIL FIELD SERVICES LTD
Well Pad ID:
Farm/Lease Name: DIAMOND SHAMROCK CORPORATION
License Status: Producing
License Date: 1985-09-09
Spud Date: 1985-09-14
Spud Drilling Contractor: UNDERWATER GAS DEVEL
Final Drill Date: 1985-09-16
Well Total Depth: 3064.00 ft
Configuration: Vertical
Latitude: 41.740000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-04-18 540 DIAMOND SHAMROCK CHEM CO GeoDate 4/18/84
Oil and Gas 1984-04-18 Issued Date 4/18/84 Expired Date 10/15/84 Acres 0024850 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00220 Proposed Drill Depth 00220
CO 1985-09-09 540 DIAMOND SHAMROCK CHEM CO GeoDate 9/9/85
Oil and Gas 1985-09-09 Issued Date 9/9/85 Expired Date 9/9/86 Acres 0024850 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03064 Proposed Drill Depth 03064
Original Spud 1985-09-14
Completed 1985-09-16
Reached Total Depth 1985-09-16
Completion Report Received 1985-12-04
Construction Permit Expires 1986-09-09
CO 1991-10-10 4128 MIDGARD ENERGY CO GeoDate 9/9/85
Change of Owner 1998-07-22 Operator changed from 4128, MIDGARD ENERGY CO to 3847, HALL & HORNING SERV INC
Change of Owner 2010-01-25 Operator changed from 3847, HALL & HORNING SERV INC to 8602, ALLIED OIL FIELD SERVICES LTD
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 2850 2976 0
2850 2976 0
2006-09-11 2865 2916 12
2865 2916 12
2850 2976 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 40000 FRAC: H2O,SAND,N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 DIAMOND SHAMROCK CHEM CO 0.00 16822.00 339
1987 DIAMOND SHAMROCK CHEM CO 25894.00 0.00 365
1988 DIAMOND SHAMROCK CHEM CO 25905.00 0.00 365
1989 DIAMOND SHAMROCK CHEM CO 21786.00 0.00 365
1990 DIAMOND SHAMROCK CHEM CO 19112.00 0.00 365
1991 MIDGARD ENERGY CO 22379.00 60.00 365
1992 MIDGARD ENERGY CO 15611.00 0.00 365
1993 MIDGARD ENERGY CO 11564.00 100.00 365
1998 HALL & HORNING SERV INC 7250.00 0.00 365
1999 HALL & HORNING SERV INC 9279.00 0.00 365
2000 HALL & HORNING SERV INC 7371.00 0.00 365
2001 HALL & HORNING SERV INC 7560.00 0.00 365
2002 HALL & HORNING SERV INC 7145.00 0.00 365
2003 HALL & HORNING SERV INC 6335.00 80.00 365
2004 HALL & HORNING SERV INC 7521.00 0.00 365
2005 HALL & HORNING SERV INC 5464.00 0.00 365
2006 HALL & HORNING SERV INC 3380.00 0.00 365
2007 HALL & HORNING SERV INC 3749.00 0.00 365
2008 HALL & HORNING SERV INC 5337.00 0.00 366
2009 ALLIED OIL FIELD SERVICES LTD 4150.00 0.00 72
2010 ALLIED OIL FIELD SERVICES LTD 5220.00 0.00 365
2011 ALLIED OIL FIELD SERVICES LTD 5004.00 0.00 365
2012 ALLIED OIL FIELD SERVICES LTD 4515.00 0.00 366
2013 ALLIED OIL FIELD SERVICES LTD 3903.00 0.00 365
2014 ALLIED OIL FIELD SERVICES LTD 4543.00 0.00 365
2015 ALLIED OIL FIELD SERVICES LTD 3487.00 0.00 365
2016 ALLIED OIL FIELD SERVICES LTD 1339.00 0.00 365
2017 ALLIED OIL FIELD SERVICES LTD 1622.00 0.00 181
2018 ALLIED OIL FIELD SERVICES LTD 2985.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 DIAMOND SHAMROCK CHEM CO Brine 339 339
1987 DIAMOND SHAMROCK CHEM CO Brine 220 365
1988 DIAMOND SHAMROCK CHEM CO Brine 290 365
1989 DIAMOND SHAMROCK CHEM CO Brine 235 365
1990 DIAMOND SHAMROCK CHEM CO Brine 415 365
1991 MIDGARD ENERGY CO Brine 210 365
1992 MIDGARD ENERGY CO Brine 0 365
1993 MIDGARD ENERGY CO Brine 0 365
1998 HALL & HORNING SERV INC Brine 0 365
1999 HALL & HORNING SERV INC Brine 160 365
2000 HALL & HORNING SERV INC Brine 0 365
2001 HALL & HORNING SERV INC Brine 90 365
2002 HALL & HORNING SERV INC Brine 75 365
2003 HALL & HORNING SERV INC Brine 197 365
2004 HALL & HORNING SERV INC Brine 0 365
2005 HALL & HORNING SERV INC Brine 86 365
2006 HALL & HORNING SERV INC Brine 0 365
2007 HALL & HORNING SERV INC Brine 0 365
2008 HALL & HORNING SERV INC Brine 258 366
2009 HALL & HORNING SERV INC Brine 0 195
2010 ALLIED OIL FIELD SERVICES LTD Brine 0 365
2011 ALLIED OIL FIELD SERVICES LTD Brine 162 365
2012 ALLIED OIL FIELD SERVICES LTD Brine 0 366
2013 ALLIED OIL FIELD SERVICES LTD Brine 61 365
2014 ALLIED OIL FIELD SERVICES LTD Brine 0 365
2015 ALLIED OIL FIELD SERVICES LTD Brine 0 365
2016 ALLIED OIL FIELD SERVICES LTD Brine 0 365
2017 ALLIED OIL FIELD SERVICES LTD Brine 0 181
2018 ALLIED OIL FIELD SERVICES LTD Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1438070510 2017-7-18 0:00: UP No Violations 5.00
-30256622 2018-11-29 0:00 UP No Violations
-475311345 2013-8-29 0:00: UP No Violations
000PL14325 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0030256622 2018-11-29 UrbanProduction Wells No Violations I conducted an inspection on this well. The well was equipped with a plunger lift assembly and in production. The tank battery was comprised of one 100 BBL tank and a heater treater separator. Valves on the separator were open. The tank battery was diked and had legible signage. The lease access was stable and was shared with the tank battery for well 2-0306.
0475311345 2013-08-29 UrbanProduction Wells No Violations The producing unit consists of a production wellhead with mechanical plunger lift and aboveground storage tank battery. The battery includes one steel 100-barrel production tank and in-ground brine unit, and separator. The battery and wellhead are enclosed in chain-link fences. The wellhead is significantly overgrown with weeds. The unit ID is present at the battery but is not readable. I did not observe any problems or signs of spills or leakage. The wellhead is located in an area which has been rendered inaccessible due to overgrowth of trees and other dense vegetation. I contacted Allied about the need for maintenance.
1047662190 2014-10-07 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead and tank battery are located on an remote parcel on the east side of the Grand River. The surrounding area is mostly overgrown with wild vegetation. The well is producing and the production records are current. The wellhead is located in an area of mature, dense vegetation rendering not locatable. The tank battery system is aged with generalized rusting of the metalic elements but is intact and free from leaking or sings of spills or other problems.
1187269173 2004-09-15 Production Wells No Violations
1356980326 2012-11-28 UrbanProduction Wells No Violations The wellhead fence enclosure is partially broken down. The tank battery (TB) consists of 2 210-bbl tanks, and mechanical separator, enclosed in a 6-foot fence. The spacing is in accordance with the rule. The fence is in disrepair. One of the 210 bbl production tanks isleaking brine. The tank battery dike is adequate. Unit ID is good. I called Cindy Moore of Allied Oil Field Serv., regarding the need for locks on the load-outs, fence repair, and repair of the leak. She indicated that repairs are being made.
1438070510 2017-07-18 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery in an otherwise wooded area along the Grand River. Fittings and connections were secure and free from leakage. The areas around the wellhead and battery had grown with advanced amounts of vegetation. I contacted the well tender (Pierre Delafransico) about the need for maintenance. He indicated that he would tend to it as soon as possible. The shared-use access to the well and battery was rutted severely in places but passable.
1594138032 2020-7-7 0:00:0 UP No Violations
PL14325 PL No Violations

For data sources see[9]

References