If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21062 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.71,"lon":-81.29,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: ROCKEFELLER OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: DIAMOND CENTER | |
License Status: Producing | |
License Date: 2003-06-27 | |
Spud Date: 2003-11-03 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2003-11-05 | |
Well Total Depth: 3230.00 ft | |
Configuration: Vertical | |
Latitude: 41.710000 | |
Longitude: -81.290000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2003-06-27 | Proposed Formations:CLINTON, Issued Date:6/27/2003, Expired Date:6/26/2004 6:00:00 AM, Drilling unit acres:45.7, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2003-11-03 | RBDMS Rec |
Completed | 2003-11-05 | RBDMS Rec |
Reached Total Depth | 2003-11-05 | RBDMS Rec |
Construction Permit Expires | 2004-06-26 | RBDMS Rec |
Completion Report Received | 2004-09-02 | RBDMS Rec |
Change of Owner | 2016-12-05 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2004-10-21 | 2948 | 2960 | 13 |
2948 | 2960 | 13 | |
2948 | 2960 | 13 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 400 Bbl | 90000 | 500 GALLONS HCL ACID & 466M SCF NITROGEN |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2004 | GREAT PLAINS EXPLORATION LLC | 9576.00 | 0.00 | 300 |
2005 | GREAT PLAINS EXPLORATION LLC | 4553.00 | 34.00 | 365 |
2006 | GREAT PLAINS EXPLORATION LLC | 5561.00 | 0.00 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | 4203.00 | 37.00 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | 3765.00 | 0.00 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | 3559.00 | 18.00 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | 2648.00 | 0.00 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | 3524.00 | 0.00 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | 4145.00 | 0.00 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | 2835.00 | 0.00 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | 2356.00 | 0.00 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | 2756.00 | 0.00 | 365 |
2016 | ROCKEFELLER OIL COMPANY LLC | 1442.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2004 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 300 |
2005 | GREAT PLAINS EXPLORATION LLC | Brine | 20 | 365 |
2006 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | Brine | 240 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | Brine | 240 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | Brine | 80 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 80 | 365 |
2016 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-286895731 | 2019-9-3 0:00:0 | UP | No Violations | |
0198641532 | 2016-02-26 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system in a chain-link enclosure. A tank battery comprised of one 100-barrel fiber-reinforced plastic (FRP) tank, one 50-barrel FRP tank, a mechanical separator in separate chain-link enclosure. The enclosure gates were unlocked and not secure. Fittings and connections were bull-plugged and secure. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. The owner must remedy the following by 04/04/2016: secure the enclosure gates with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
0218123540 | 2018-04-27 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load-lines were no locked and secure, and the tank to separator spacing, and spacing between the well and battery, were not in compliance. At the time of this inspection, I observed the following: the noted deficiencies remained. In addition, the unit ID signage had not been updated to reflect the change in ownership that had occurred in 2016. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance. |
0840425533 | 2017-12-12 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load-lines were no locked and secure, and the tank to separator spacing, and spacing between the well and battery, were not in compliance. At the time of this inspection, I observed the following: the noted deficiencies remained. In addition, the unit ID signage had not been updated to reflect the change in ownership that had occurred in 2016. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance. |
1351282771 | 2012-10-26 | UrbanProduction Wells | No Violations | The unit consists of a 2-tank battery with mechanical separator enclosed in a 6-foot chain link fence. The spacing is in accordance with the rule, and the valves and mechanicals are in good repair. I did not observe any signs of leaking product or gas vapors. The wellhead is fitted with a mechanical lift device and is located in a separate enclosure. The gates on the enclosures are not locked. The tank battery dike is missing along the western boundary, but is acceptable elsewhere. I called Jim Williams of Great Plains and advised him about the need for locks and dike repair. He indicated that the repairs would be made as soon as possible. |
1527879380 | 2018-06-01 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load-lines were no locked and secure, and the tank to separator spacing, and spacing between the well and battery, were not in compliance. At the time of this inspection, I observed the following: the noted deficiencies remained. In addition, the unit ID signage had not been updated to reflect the change in ownership that had occurred in 2016. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance. |
1545377851 | 2017-09-06 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were not secured with locks and the tank spacing within the battery was not compliant . In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress. |
1587577641 | 2020-4-22 0:00: | UP | No Violations | |
1658777152 | 2009-09-16 | Preliminary Restoration | No Violations | Preliminary restoration meets the requirements of 1509.072 ORC. |
198641532 | 2016-2-26 0:00: | UP | No Violations | 0.50 |
218123540 | 2018-4-27 0:00: | UP | No Violations | 0.50 |
840425533 | 2017-12-12 0:00 | UP | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0198641532 | US-OH-120117 | 2016-04-27 | LOCKS | |
0198641532 | US-OH-120118 | 2016-04-27 | Violation of tank spacing requirements |
For data sources see[9]