X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21066

Well Details

Well ID: 34-085-21066
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: STEVE
License Status: Producing
License Date: 2004-09-30
Spud Date: 2004-10-04
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2004-10-21
Well Total Depth: 3250.00 ft
Configuration: Vertical
Latitude: 41.650000
Longitude: -81.390000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-07-01 Proposed Formations:CLINTON, Issued Date:7/1/2003, Expired Date:6/30/2004 6:00:00 AM, Drilling unit acres:73, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2004-09-30 Proposed Formations:CLINTON, Issued Date:9/30/2004, Expired Date:9/30/2005 6:00:00 AM, Drilling unit acres:33, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-10-04 RBDMS Rec
Completed 2004-10-21 RBDMS Rec
Reached Total Depth 2004-10-21 RBDMS Rec
Completion Report Received 2005-01-04 RBDMS Rec
Construction Permit Expires 2005-09-30 RBDMS Rec
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-02-22 3006 3034 13
3006 3034 13
3006 3034 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 400 Bbl 90000 469M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 GREAT PLAINS EXPLORATION LLC 1317.00 0.00 60
2005 GREAT PLAINS EXPLORATION LLC 57757.00 95.00 365
2006 GREAT PLAINS EXPLORATION LLC 38381.00 71.00 365
2007 GREAT PLAINS EXPLORATION LLC 16548.00 41.00 365
2008 GREAT PLAINS EXPLORATION LLC 8900.00 34.00 365
2009 GREAT PLAINS EXPLORATION LLC 7461.00 90.00 365
2010 GREAT PLAINS EXPLORATION LLC 6340.00 0.00 365
2011 GREAT PLAINS EXPLORATION LLC 5724.00 21.00 365
2012 GREAT PLAINS EXPLORATION LLC 5362.00 52.00 366
2013 GREAT PLAINS EXPLORATION LLC 4795.00 27.00 365
2014 GREAT PLAINS EXPLORATION LLC 4299.00 32.00 365
2015 GREAT PLAINS EXPLORATION LLC 4777.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 3354.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 GREAT PLAINS EXPLORATION LLC Brine 0 60
2005 GREAT PLAINS EXPLORATION LLC Brine 0 365
2006 GREAT PLAINS EXPLORATION LLC Brine 230 365
2007 GREAT PLAINS EXPLORATION LLC Brine 320 365
2008 GREAT PLAINS EXPLORATION LLC Brine 8 365
2009 GREAT PLAINS EXPLORATION LLC Brine 80 365
2010 GREAT PLAINS EXPLORATION LLC Brine 240 365
2011 GREAT PLAINS EXPLORATION LLC Brine 160 365
2012 GREAT PLAINS EXPLORATION LLC Brine 160 366
2013 GREAT PLAINS EXPLORATION LLC Brine 100 365
2014 GREAT PLAINS EXPLORATION LLC Brine 80 365
2015 GREAT PLAINS EXPLORATION LLC Brine 80 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1331016155 2005-2-14 0:00: PW No Violations
-1347485522 2005-2-24 0:00: PW No Violations
-1762826234 2019-8-7 0:00:0 UP No Violations
-182096906 2007-4-16 0:00: DD No Violations
-1939304977 2017-12-12 0:00 UP No Violations 0.50
-467352562 2017-9-8 0:00:0 UP No Violations 0.50
-642921754 2004-10-9 0:00: DD No Violations
-94223647 2015-2-6 0:00:0 UP No Violations 0.50
0094223647 2015-02-06 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well is located at the terminus of Riverside Commons Dr. in an otherwise undeveloped area. The wellhead and battery are located approximately 600 feet to the north, after entry to the lease road. Surroundings include well developed trees and vegetation. My inspection noted the following: The well is comprised of a wellhead pump jack and tank battery with 1 210-barrel production tank and 1 100-barrel brine tank. At the time of my inspection, the area is covered with up to 14 inches of snow and, as such, elements of the system are obscured with snow cover. Connections and fittings are secure and free from signs of leakage or problems. Evaluation of battery interior, lease road condition, and other surficial features is not possible due to snow cover.
0182096906 2007-04-16 Drill / Deepen / Reopen No Violations
0462954897 2004-10-13 Drill / Deepen / Reopen No Violations drilling at 3247
0467352562 2017-09-08 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection I observed the following elements: A wellhead with pump jack system, and a tank battery system in a open area behind an industrial facility. . Fittings and connections at the well and battery were secure and free from evidence of problems or leakage. The load-line valves were plugged and secure. The secondary containment was intact. The tank lids were closed and sealed. I walked the area around the tank and wellhead and did not observe any signs of impact or problems. The access road was in good condition.
0642921754 2004-10-09 Drill / Deepen / Reopen No Violations surface
0760742926 2012-08-27 Production Wells No Violations The unit is comprised of a two-tank battery (1, 210-barrel production and 1, 100-barrel brine) and a wellhead with mechanical lift. I observed the wellhead and tank battery areas to be in generally good condition. The tank and well spacing is in accordance with 1509:9-9-05. The tank battery dike is missing along some portions and needs repaired and/or built up. I did not observe any leaks, spills, or other signs of contamination. I called Jim Williams about the dike repairs, He indicated he would take care of within the next two weeks.
1331016155 2005-02-14 Production Wells No Violations
1347485522 2005-02-24 Production Wells No Violations Area leveled ready for rest check this spring.
1469088644 2004-10-13 Drill / Deepen / Reopen No Violations drilling 800
1554677172 2014-02-28 UrbanProduction Wells No Violations No changes since the last inspection. The unit is producing and no violations noted.
1755202948 2016-02-12 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection I observed the following elements: A wellhead with pump jack system, and a tank battery system in a open area behind an industrial facility. Access to the wellhead is via a short, unpaved access road. Fittings and connections at the well and battery were secure and free from evidence of problems or leakage. The load-line valves were plugged and secure. The secondary containment was intact. The tank lids were closed and sealed. I walked the area around the tank and wellhead and did not observe any signs of impact or problems.
1939304977 2017-12-12 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I found the following: Fittings and connections at the well and battery were secure and free from leakage. The well was in active production. Production reports were current. The short access road to the well and battery from the asphalt parking area was in good condition, with a light snow covering. I noted that the 210-barrel production tank was severely corroded in places and may need replaced soon. I will notify the owner about the observed corrosion on the tank.
436860007 2020-4-14 0:00: UP No Violations
462954897 2004-10-13 0:00 DD No Violations
760742926 2012-8-27 0:00: PW No Violations

For data sources see[9]

References