If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21075 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.69,"lon":-81.31,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: ROCKEFELLER OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: TYLER | |
License Status: Producing | |
License Date: 2003-08-15 | |
Spud Date: 2003-10-18 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2003-10-25 | |
Well Total Depth: 3260.00 ft | |
Configuration: Vertical | |
Latitude: 41.690000 | |
Longitude: -81.310000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2003-08-15 | Proposed Formations:CLINTON, Issued Date:8/15/2003, Expired Date:8/14/2004 6:00:00 AM, Drilling unit acres:48, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2003-10-18 | RBDMS Rec |
Completed | 2003-10-25 | RBDMS Rec |
Reached Total Depth | 2003-10-25 | RBDMS Rec |
Construction Permit Expires | 2004-08-14 | RBDMS Rec |
Completion Report Received | 2004-09-02 | RBDMS Rec |
Change of Owner | 2016-12-05 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2004-10-22 | 2968 | 2980 | 13 |
2968 | 2980 | 13 | |
2968 | 2980 | 13 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 400 Bbl | 90000 | 500 GALLONS HCL ACID & 466M SCF NITROGEN |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2004 | GREAT PLAINS EXPLORATION LLC | 10448.00 | 164.00 | 305 |
2005 | GREAT PLAINS EXPLORATION LLC | 7661.00 | 167.00 | 365 |
2006 | GREAT PLAINS EXPLORATION LLC | 4784.00 | 103.00 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | 3540.00 | 209.00 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | 3109.00 | 148.00 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | 2834.00 | 345.00 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | 2641.00 | 239.00 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | 2602.00 | 101.00 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | 2707.00 | 112.00 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | 2369.00 | 64.00 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | 2189.00 | 33.00 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | 644.00 | 0.00 | 365 |
2016 | ROCKEFELLER OIL COMPANY LLC | 750.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2004 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 305 |
2005 | GREAT PLAINS EXPLORATION LLC | Brine | 170 | 365 |
2006 | GREAT PLAINS EXPLORATION LLC | Brine | 80 | 365 |
2007 | GREAT PLAINS EXPLORATION LLC | Brine | 775 | 365 |
2008 | GREAT PLAINS EXPLORATION LLC | Brine | 320 | 365 |
2009 | GREAT PLAINS EXPLORATION LLC | Brine | 400 | 365 |
2010 | GREAT PLAINS EXPLORATION LLC | Brine | 320 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | Brine | 320 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | Brine | 320 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 190 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 365 |
2016 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1431135407 | 2020-3-26 0:00: | UP | No Violations | |
-1899185331 | 2017-4-19 0:00: | UP | No Violations | 0.50 |
-316207553 | 2017-9-6 0:00:0 | UP | No Violations | 0.50 |
-544154449 | 2020-2-14 0:00: | UP | No Violations | |
-621272031 | 2017-12-12 0:00 | UP | No Violations | |
0316207553 | 2017-09-06 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: there had been leakage from a hole in the production tank. At the time of this inspection, the leakage had been repaired. I noted, however, that the load-line valves and enclosure gates were not locked and secure, the tank spacing does not meet requirements, and the ID signage has not been updated to reflect the transfer of ownership that had occurred over six months prior. I have advised the owner that I will issue a separate compliance notice regarding these deficiencies. |
0621272031 | 2017-12-12 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I found the following: Fittings and connections at the well and battery were secure and free from leakage. The well was in active production. Production reports were current. The short access road to the well and battery from the asphalt parking area was in good condition, with a light snow covering. |
1066925199 | 2003-10-23 | Production Wells | No Violations | Drilling at 2580 no fluid flow. |
1068140402 | 2003-11-05 | Drill / Deepen / Reopen | No Violations | On site to check pits Water triuck on site sucking water out of blow pit. |
1092155361 | 2004-07-27 | Preliminary Restoration | No Violations | |
1388310162 | 2016-02-16 | UrbanProduction Wells | Violations Noted | I inspected this well location as part of routine inspection activity. At the time of this inspection I observed the following elements: A wellhead with gasoline-fired pump jack system, a mechanical separator, and a tank battery system located adjacent to the existing parking and drive areas in separate enclosures that were locked. The battery is comprised of two 100-barrel fiber-reinforced plastic (FRP) tanks. Access to the wellhead is via the shared, paved truck delivery driveway. Fittings and connections at the well and battery were secure and free from evidence of problems or leakage. Load lines were plugged and secure. I noted a small pinhole in one of the tanks which was not actively leaking but showed signs of past leakage. I walked the areas surrounding the well and battery and did not observe any evidence of impact relating to the production activity. The owner must remedy the following by 04 /04/2016: repair/replace the leaking tank. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
1600873237 | 2020-9-23 0:00: | UP | No Violations | |
1899185331 | 2017-04-19 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to a previously-issued compliance notice for the following: leaking from the production tank. At the time of this inspection, I observed the following: There had been no further leaking from the storage tank. I did note that the load-line valves were not secured with locks as required. In addition, the ID signage has not been upgraded to reflect the change in ownership and is missing information required under OAC 1501:9-9-05(E)(1). I have contacted John Magnussen about the unaddressed deficiencies and he advised that the compliance issues are being tended to as soon as possible. I also attempted to contact Richard Osborne Sr. and, as of the filing of this report, he has not responded to multiple messages. |
1992352978 | 2012-10-26 | UrbanProduction Wells | No Violations | The unit consists of a 2-tank battery with mechanical separator in a 6-foot chain link fence. The spacing is in accordance with the rule, and the valves and mechanicals are in good repair. The dike is adequate. The loadout valves need locked or the gate needs a lock. I did not observe any signs of leaking product or gas vapors. The wellhead is fitted with a pumpjack and is enclosed in a 6-foot wooden fence. I called Tim Reilly of Great Plains and advised him about the need for locks. I indicated that the requested date for completion is 12/31/2012 |
538257027 | 2019-9-3 0:00:0 | UP | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1388310162 | US-OH-111501 | 2017-12-01 | 9-9-05(A)1 | Well insufficiently equipped to prevent escape of oil and gas |
For data sources see[9]