34-085-21086

Well Details

Well ID: 34-085-21086
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Painesville Township
Operator Name: ALLIED OIL FIELD SERVICES LTD
Well Pad ID:
Farm/Lease Name: TWIN RIVERS TECHNOLOGIES
License Status: Final Restoration
License Date: 2016-03-21
Spud Date: 2004-01-07
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2004-01-10
Well Total Depth: 3071.00 ft
Configuration: Vertical
Latitude: 41.750000
Longitude: -81.230000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-12-02 Proposed Formations:CLINTON, Issued Date:12/2/2003, Expired Date:12/1/2004 6:00:00 AM, Drilling unit acres:24.21, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-01-07 LANDOWNER WAIVER TO NOT REMOVE FLOWLINE
Completed 2004-01-10 LANDOWNER WAIVER TO NOT REMOVE FLOWLINE
Reached Total Depth 2004-01-10 LANDOWNER WAIVER TO NOT REMOVE FLOWLINE
Completion Report Received 2004-08-05 LANDOWNER WAIVER TO NOT REMOVE FLOWLINE
Change of Owner 2010-01-25 Operator changed from 3847, HALL & HORNING SERV INC to 8602, ALLIED OIL FIELD SERVICES LTD
APP 2016-03-21 Proposed Formations:CLINTON, Issued Date:3/21/2016, Expired Date:3/21/2018 12:00:00 PM, Drilling unit acres:24.21, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2016-04-07 LANDOWNER WAIVER TO NOT REMOVE FLOWLINE
Construction Permit Expires 2017-03-21 LANDOWNER WAIVER TO NOT REMOVE FLOWLINE
Record Last Modified 2017-05-25 LANDOWNER WAIVER TO NOT REMOVE FLOWLINE

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-10-06 2892 2948 50
2892 2948 50
2892 2948 50

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2000 Bbl 20000 600 GALLONS SC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 HALL & HORNING SERV INC 0.00 0.00 0
2004 HALL & HORNING SERV INC 12772.00 143.00 365
2005 HALL & HORNING SERV INC 5478.00 55.00 365
2006 HALL & HORNING SERV INC 2941.00 60.00 365
2007 HALL & HORNING SERV INC 3112.00 0.00 365
2008 HALL & HORNING SERV INC 2421.00 57.00 366
2009 HALL & HORNING SERV INC 1695.00 0.00 195
2010 ALLIED OIL FIELD SERVICES LTD 2133.00 17.00 365
2011 ALLIED OIL FIELD SERVICES LTD 1836.00 0.00 365
2012 ALLIED OIL FIELD SERVICES LTD 2379.00 0.00 366
2013 ALLIED OIL FIELD SERVICES LTD 1611.00 54.00 365
2014 ALLIED OIL FIELD SERVICES LTD 2117.00 0.00 365
2015 ALLIED OIL FIELD SERVICES LTD 1612.00 0.00 365
2016 ALLIED OIL FIELD SERVICES LTD 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 HALL & HORNING SERV INC Brine 0 0
2004 HALL & HORNING SERV INC Brine 2289 365
2005 HALL & HORNING SERV INC Brine 1970 365
2006 HALL & HORNING SERV INC Brine 818 365
2007 HALL & HORNING SERV INC Brine 0 365
2008 HALL & HORNING SERV INC Brine 766 366
2009 HALL & HORNING SERV INC Brine 0 195
2010 ALLIED OIL FIELD SERVICES LTD Brine 494 365
2011 ALLIED OIL FIELD SERVICES LTD Brine 4680 365
2012 ALLIED OIL FIELD SERVICES LTD Brine 711 366
2013 ALLIED OIL FIELD SERVICES LTD Brine 245 365
2014 ALLIED OIL FIELD SERVICES LTD Brine 731 365
2015 ALLIED OIL FIELD SERVICES LTD Brine 0 365
2016 ALLIED OIL FIELD SERVICES LTD Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1095709871 2004-1-9 0:00:0 DD No Violations
-1419523659 2012-11-28 0:00 UP No Violations
-613175110 2005-7-15 0:00: PL No Violations
0613175110 2005-07-15 Preliminary Restoration No Violations
1095709871 2004-01-09 Drill / Deepen / Reopen No Violations rig drill at 2100. No violation at site.
1419523659 2012-11-28 UrbanProduction Wells No Violations The unit consists of a pumpjack unit in a 6-foor fenced enclosure. The TB consists of 2 210-bbl tanks, and mechanical separator, enclosed in a 6-foot fence. The spacing is in accordance with the rule. The tank battery dike is missing almost completely. Unit ID is absent.. I called Cindy Moore of Allied Oil Field Serv., regarding the need for dike repair and ID. She indicated that this unit is going to be plugged and abandoned.
1459970206 2016-04-06 Plug / Plug Back No Violations I was on location for inspection during plugging and abandonment activity being conducted by Nicks Well Plugging Service. At the time of this inspection, the pump jack system and sucker rods have been removed from the wellhead. Crews were blowing down the residual well pressure. After blow-down the well was stable. Plugging activities were executed as described in the associated report of plugging and abandonment dated 04/06/2016.
1470686662 2016-07-01 Final Restoration No Violations I inspected this well location as part of evaluation for the completion of Final Restoration requirements. At the time of this inspecton, I met at the location with Mr. Scott Forster, VP of Hardy Realty, LLC., owner of the property. The former well location has been graded and restored to match the surrounding grade and conditions. The former tank battery location has been restored. The former flowline has been evacuated and abandoned in place, with Form 5 waiver on file. Mr. Forster indicated that they are satisfied with the site restoration. Final Restoraiton has been completed.
1753439575 2014-10-07 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead and tank battery are located on within a gated industrial facility and the end of Hardy Rd. The well is producing and the production records are current. The pump jack shows some age and wear but appears functional. I did not observe any signs of leakage or problems at the wellhead. The tank battery system is aged and decayed in places. The secondary containment is missing on the east side of the battery. The load out on the southern-most 100-barrel tank is leaking brine from the bull-plugged fitting. I advised Allied about the minor leak.

For data sources see[9]