Well Details

Well ID: 34-085-21114
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: NANCY
License Status: Producing
License Date: 2004-07-15
Spud Date: 2004-10-14
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2004-10-18
Well Total Depth: 3217.00 ft
Configuration: Vertical
Latitude: 41.650000
Longitude: -81.400000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-07-15 Proposed Formations:CLINTON, Issued Date:7/15/2004, Expired Date:7/15/2005 6:00:00 AM, Drilling unit acres:39, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-10-14 RBDMS Rec
Completed 2004-10-18 RBDMS Rec
Reached Total Depth 2004-10-18 RBDMS Rec
Completion Report Received 2005-01-04 RBDMS Rec
Construction Permit Expires 2005-07-15 RBDMS Rec
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-02-22 3010 3018 13
3010 3018 13
3010 3018 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 343 Bbl 90000 490M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 GREAT PLAINS EXPLORATION LLC 1487.00 34.00 70
2005 GREAT PLAINS EXPLORATION LLC 11305.00 160.00 365
2006 GREAT PLAINS EXPLORATION LLC 2402.00 0.00 365
2007 GREAT PLAINS EXPLORATION LLC 2259.00 72.00 365
2008 GREAT PLAINS EXPLORATION LLC 1632.00 21.00 365
2009 GREAT PLAINS EXPLORATION LLC 2055.00 0.00 365
2010 GREAT PLAINS EXPLORATION LLC 1623.00 0.00 365
2011 GREAT PLAINS EXPLORATION LLC 1985.00 0.00 365
2012 GREAT PLAINS EXPLORATION LLC 1858.00 0.00 366
2013 GREAT PLAINS EXPLORATION LLC 1694.00 0.00 365
2014 GREAT PLAINS EXPLORATION LLC 1623.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 1338.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 1.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 GREAT PLAINS EXPLORATION LLC Brine 0 70
2005 GREAT PLAINS EXPLORATION LLC Brine 72 365
2006 GREAT PLAINS EXPLORATION LLC Brine 230 365
2007 GREAT PLAINS EXPLORATION LLC Brine 320 365
2008 GREAT PLAINS EXPLORATION LLC Brine 400 365
2009 GREAT PLAINS EXPLORATION LLC Brine 210 365
2010 GREAT PLAINS EXPLORATION LLC Brine 240 365
2011 GREAT PLAINS EXPLORATION LLC Brine 400 365
2012 GREAT PLAINS EXPLORATION LLC Brine 240 366
2013 GREAT PLAINS EXPLORATION LLC Brine 220 365
2014 GREAT PLAINS EXPLORATION LLC Brine 70 365
2015 GREAT PLAINS EXPLORATION LLC Brine 0 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-602636260 2020-4-14 0:00: UP No Violations
0097601066 2010-06-18 Preliminary Restoration No Violations Preliminary restoration was complete.
0160154720 2017-09-22 UrbanProduction Wells Violations Noted I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated battery located on an otherwise undeveloped parcel. Fittings and connections at the wellhead and battery were free from leakage. The secondary containment was intact and free from signs of spills, leaks, or other problems. The gravel-paved access road was in good condition. I observed the following deficiencies: The load-line valves were not locked or secure. The ID signage has not been updated to reflect the change in ownership that occurred in 2016. The owner must resolve these deficiencies by 10/13/17 or be subject to additional enforcement action. Please contact inspector Stephen Tompkins at 330-907-4647with any questions about this inspection.
0239570165 2010-10-15 Production Wells No Violations Fences need to be installed.
0646521185 2012-08-27 UrbanProduction Wells No Violations The unit is comprised of a two-tank battery (1, 210-barrel production and 1, 100-barrel brine) and a wellhead with pump jack. I observed the wellhead and tank battery areas to be in generally good condition. The tank spacing is in accordance with 1509:9-9-05. The tank battery dike is in good condition. I did not observe any leaks, spills, or other signs of contamination. No violations noted.
0895056743 2015-02-06 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well is located north of Riverside Commons Drive on an elevated portion of made-land created as part of the construction of St. Rt. 2. The wellhead and battery are encompassed on the north and west sides by the St. Rt. 2 and the interchange with Lost Nation Road. My inspection noted the following: The well is comprised of a wellhead pump jack and tank battery with 1 210-barrel production tank and 1 100-barrel brine tank. At the time of my inspection, the area is covered with up to 14 inches of snow and, as such, elements of the system are obscured with snow cover. Connections and fittings are secure and free from signs of leakage or problems. Evaluation of battery interior, lease road condition, and other surficial features is not possible due to snow cover.
1229030926 2011-08-01 UrbanPreliminary Restoration No Violations Preliminary restoration passed.
1286005044 2005-02-14 Production Wells No Violations
1455308006 2016-02-12 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: The short unpaved access road from Riverside Commons Drive was in good condition. The production elements consisted of the following: wellhead with pump jack system tank battery with one 210-barrel steel tank, one 100-barrel steel tank, mechanical separator unit. The well was in production. The 210-barrel tank was exhibiting some exterior corrosion but was intact. Secondary containment was intact. Fittings and connections were secure and free from signs of leakage.
1513088453 2017-12-12 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked and secure, and ID signage . At the time of this inspection, I observed the following: the load line valves were locked and the ID signage had been updated. The items noted in the compliance notice had been addressed. I did note that there was no enclosure at the wellhead or battery and will discuss with the owner the reason for the missing enclosure.
160154720 2017-9-22 0:00: UP No Violations 0.50
2114008704 2005-02-24 Production Wells No Violations area leveled will check rest this spring.
239570165 2010-10-15 0:00 PW No Violations
262391865 2019-8-7 0:00:0 UP No Violations
646521185 2012-8-27 0:00: UP No Violations
895056743 2015-2-6 0:00:0 UP No Violations 0.50
97601066 2010-6-18 0:00: PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0160154720 US-OH-115701 2018-03-12 ID (a-i)
0160154720 US-OH-115702 2018-03-12 LOCKS

For data sources see[9]